V20160909
10
Mounting SecureFit Spacers to the Hedrick Motorized Focuser
1.
The face plate of the focuser (200340) has four threaded holes that should be used to
mount any of Planewave’s SecureFit adapter. Use the ¼-20 screws provided with
your SecureFit adapter to mount it on the face of the focuser.
2.
The remaining four holes has screws that hold the face plate to the body of the
focuser and should not be removed.
3.
There are also a series of set screws that are used to level the face plate relative to the
image plane. These set screws should not be removed or loosened in any way.
1)
SecureFit
Mounting Screws
2) Face Plate
Attachment Screws
3) Face Plate Leveling
Screws