![Planet XGSW-28040 Quick Installation Manual Download Page 5](http://html1.mh-extra.com/html/planet/xgsw-28040/xgsw-28040_quick-installation-manual_1563397005.webp)
5
3. Terminal Setup
To configure the system, connect a serial cable to a
COM
port
on a PC or
notebook computer and to serial (console) port of the XGSW Managed Switch. The
console port of the Managed Switch is DCE already, so that you can connect the
console port directly through PC without the need of Null Modem.
PC / Workstation
with
Terminal emulation software
Serial Port
RS-232
Serial Port
115200,8,n,1
XGSW Managed Switch
A terminal program is required to make the software connection to the XGSW
Managed Switch. Windows’
Hyper Terminal
program may be a good choice. The
Hyper Terminal can be accessed from the
Start
menu.
1. Click
START
, then
Programs
,
Accessories
and then
Hyper Terminal
.
2. When the following screen appears, make sure that the COM port should be
configured as:
Baud : 115200
Data bits : 8
Parity : None
Stop bits : 1
Flow Control : None