1

3. Installation

3.1 Install Industrial Ethernet Extender – IVC-2002

The  Industrial  Ethernet  Extender  does  not  require  any  software 

configuration.  Users  can  immediately  use  any  feature  of  this  product 

simply  by  attached  the  cables  and  plug  power  on.  There  is  some 
key  limitation  on  the  Industrial  Ethernet  Extender.  Please  check  the 
following items:

IVC-2002:

  The  device  is  used  for 

Point-to-Point

  connection  only 

(Master  device  to  Slave  device)  and  has  equipped  with  one  RJ-11  and 
one BNC connectors for VDSL2 port for network link connection.

Phone wire:

 Depending on the quality of telephone line, the maximum 

distance  of  one  VDSL  segment  is  1.4km  (5249ft)  with  AWG  24 
telephone wires.

Coaxial:

  Depending  on  the  quality  of  coaxial  cable,  the  maximum 

distance of one VDSL segment is 2.4km (9842ft) with 5C coaxial cable.

The  distances  will  be  changed  by  the  quality  of  telephone  wires  and 
coaxial cables.

Summary of Contents for IVC-2002

Page 1: ...Industrial Ethernet Extender IVC 2002 User s Manual...

Page 2: ...se PLANET has made every effort to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is s...

Page 3: ...nterference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio inte...

Page 4: ...IVC 2002 12 2 1 2 MODE DIP Switch 13 2 2 The Upper Panel 14 3 Installation 15 3 1 Install Industrial Converter IVC 2002 15 3 2 IVC 2002 BNC RJ 11 Proper Connection 16 3 3 IVC 2002 Application Connect...

Page 5: ...tender x 1 DIN Rail Kit Wall Mount Kit User s Manual x 1 If any of these items are missing or damaged please contact your dealer immediately if possible retain the carton including the original packin...

Page 6: ...ymmetric data rate within 200m and up to 28 2Mbps for asymmetric data rate at 1 4km The IVC 2002 BNC performance is up to 99 65Mbps for asymmetric data rate within 200m and up to 31 4Mbps for asymmetr...

Page 7: ...or the transmission of Upstream and Downstream signals Complies with IEEE 802 3 IEEE 802 3u and IEEE 802 3x standards DMT Discrete Multi Tone line coding Half Duplex Back Pressure and IEEE 802 3x Full...

Page 8: ...ode Selectable target Band Plan Selectable target SNR mode Encoding VDSL DMT ITU T G 997 1 ITU T G 993 1 VDSL ITU T G 993 2 VDSL2 Profile 17a Support LED Indicators P1 Green P2 Green Fault Green Maste...

Page 9: ...2000m 39 9Mbps 2200m 35 6Mbps 2400m 31 4Mbps Symmetric Mode VDSL RJ 11 BNC 200m 91 99Mbps 400m 74 79Mbps 600m 54 51Mbps 800m 38 34Mbps 1000m 27 21Mbps 1200m 24 15Mbps 1400m 21 10Mbps 200m 95 99Mbps 40...

Page 10: ...Temperature 40 80 C Operating Humidity 10 to 90 relative humidity non condensing Storage Humidity 10 to 90 relative humidity non condensing Regulation Compliance FCC Part 15 Class A CE Standards Comp...

Page 11: ...Industrial Ethernet Extender familiarize yourself with its display indicators and ports Front panel illustrations in this chapter display the unit LED indicators Before connecting any network device t...

Page 12: ...cate that the VDSL link is actively sending or receiving data over that port Sync Green Light Indicate that the VDSL link is established Fast Blink Indicate that the VDSL link is at training status ab...

Page 13: ...the Master device mode usually the Master device will be located at the data center of ISP or enter prise to link to the backbone t Slave Customer Premises Equipment the Slave device mode usually the...

Page 14: ...default setting the four DIP switch at ON posi tion and operate as Slave For operate as Master please adjust the DIP 1 switch to OFF position Adjust other DIP switch setting to fill different network...

Page 15: ...s IVC 2002 The device is used for Point to Point connection only Master device to Slave device and has equipped with one RJ 11 and one BNC connectors for VDSL2 port for network link connection Phone w...

Page 16: ...45 Connections 100m 328ft Max Coaxial Cable Connections 2 4km Max No Connection Slave IVC 2002 P1 P2 Slave Master Sync ACT FAULT RJ 11 BNC VDSL 4 3 2 1 IVC 2004PT Master Inter Symm 9dB Slave OFF ON Fa...

Page 17: ...ion Advantage of IVC 2002 which it compatibles with PLANET VC 201A and VC 202A Without spend extra cost to deploy a new local Internet in apartment hotel campus and hospitality environment It can use...

Page 18: ...ut the converter then you must ensure t It is accessible and cables can be connected easily t Cabling is away from sources of electrical noise such as radios transmitters and power lines and fluoresce...

Page 19: ...edundant powers input Please follow the steps below to insert the power wire 1 Insert positive negative DC power wires into the contacts 1 and 2 for POWER 1 or 5 and 6 for POWER 2 Input DC12 48V V1 V1...

Page 20: ...hernet Extender will detect the fault status of the power failure and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts Insert the...

Page 21: ...use IGS 801 PLANET 8 Port Industrial Gigabit Switch as the example However the steps for PLANET Industrial Switch Industrial Ethernet Extender are similar 3 6 1 Install DIN Rail Mounting The DIN Rail...

Page 22: ...for remove it from track 3 6 2 Wall Mount Plate Mounting To install the Industrial Ethernet Extender on the wall please follows the instructions described below Step 1 Remove the DIN Rail from the Ind...

Page 23: ...the wall mount plate on the Industrial Ethernet Extender Step 4 Use the hook holes at the corners of the wall mount plate to hang the Industrial Ethernet Extender on the wall Step 5 To remove the wal...

Page 24: ...h other to make it work SYMPTOM TP LED does not light after cable is connected to the port CHECKPOINT 1 Verify you are using the Cat 5 5e or 6 cables with RJ 45 connector to connect to the port 2 If y...

Page 25: ...infrastructure Q3 What is the best distance for IVC 2002 A3 In order to guarantee the stability and better quality of network so we would suggest the distance within 1 4 kilometer is the best for RJ 1...

Page 26: ...el over a network channel The greater the ratio the easier it is to identify and subsequently isolate and eliminate the source of noise Generally speaking the higher SNR value gets better line quality...

Page 27: ...000 3 3 1995 A1 2001 A2 2005 Immunity EN 55024 1998 A1 2001 A2 2003 ESD IEC 61000 4 2 2001 RS IEC 61000 4 3 2008 EFT Burst IEC 61000 4 4 2004 Surge IEC 61000 4 5 2005 CS IEC 61000 4 6 2008 Magnetic Fi...

Page 28: ...This page is intentionally left blank...