2.6  M23 DC Power Cable Wiring

Please  use  the  power  cable  with  the  M23  5-pin  female  connector  from  the 
Industrial  M12  Ethernet  Switch  package  for  DC  power  input.  The  M23  DC  power 

cable pin assignment is shown below:

V2

V2

V1

V1

CB-M23FSF-120 M23 DC power cable pin assignment and wiring code

V2-

V2+

V1-

V1+

V1 positive (+) pin = white cable

V1 negative (-) pin = brown cable

V2 positive (+) pin = black cable

V2 negative (-) pin = yellow cable

Note

1. Make sure you connect the correct power pin to your DC power 

source.

2. The wire gauge for the power cable should be in the range of 12 

~ 24 AWG.

3. The DC power input range is 12 ~ 56V DC.

Summary of Contents for ISW-808PT-M12

Page 1: ...Industrial 8 Port 10 100TX M12 802 3at PoE Switch 40 75 degrees C ISW 808PT M12 ISW 808PT M12A User s Manual ...

Page 2: ... inaccuracies that may be contained in this User s Manual PLANET makes no commitment to update or keep current the information in this User s Manual and reserves the right to make improvements to this User s Manual and or to the products described in this User s Manual at any time without notice If you find information in this manual that is incorrect misleading or incomplete we would appreciate y...

Page 3: ...uce the unnecessary power consuming it is strongly suggested to remove the power connection for the device if this device is not intended to be active WEEE Warning To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment end users of electrical and electronic equipment should understand the meaning...

Page 4: ...on 6 2 1 Switch Front Panel 6 2 2 LED Indicators 7 2 3 M12 10 100TX Connector Pin Assignment 8 2 4 M12 4 pin Male to RJ45 8 pin Cable 9 2 5 M23 DC Power Connector Pin Assignment 10 2 6 M23 DC Power Cable Wiring 11 3 Connecting M12 Cable 12 4 Customer Support 15 ...

Page 5: ...56V IP67 aluminum ISW 808PT M12A IP50 metal Industrial M12 Ethernet Switch is used as an alternative name in this Quick Installation Guide Open the box of the Industrial M12 Ethernet Switch and carefully unpack it The box should contain the following items The Industrial M12 Ethernet Switch x 1 User s manual x 1 1 2m 4 pin D code M12 to RJ45 UTP cable x 1 DIN rail kit x 1 Screws x 1 set If any ite...

Page 6: ...ont panel of the Industrial M12 Ethernet Switch LNK ACT PoE in Use LNK ACT PoE in Use LNK ACT PoE in Use LNK ACT PoE in Use 1 5 2 6 3 7 4 8 Fault PWR2 PWR1 GND V2 V2 V1 V1 ISW 808PT M12 PoE M12 PoE Usage 180W 120W 60W TX RX RX TX DC Input 12 56V 6A max Figure 2 1 ISW 808PT M12 Front Panel ...

Page 7: ...ower Usage LEDs Figure 2 2 ISW 808PT M12A Front Panel 2 2 LED Indicators System LED Color Function PWR 1 Green Lights to indicate DC power input 1 has power PWR 2 Green Lights to indicate DC power input 2 has power Fault Red Lights to indicate either power 1 or power 2 has no power ...

Page 8: ...tem consumes over 120 watt PoE power budget Blinks To indicates that the PoE usage is around 90W to 120W 60W Amber Lights To indicate the system consumes over 60 watt PoE power budget Blinks To indicates that the PoE usage is around 30W to 60W 2 3 M12 10 100TX Connector Pin Assignment The Industrial M12 Ethernet Switch front panel provides eight 10 100BASE TX Fast Ethernet ports in the form of M12...

Page 9: ...thernet ports of the corresponding Ethernet devices are also running in auto negotiation mode otherwise the Ethernet performance will be poor TX RX TX RX 1 2 3 4 1 2 3 6 TX TX RX RX M12 4 Pin M to RJ 45 8 Pin Cross Over Cable Wiring Cross Over Cable Wiring TX RX TX RX 1 2 3 4 1 2 3 6 RX RX TX TX M12 4 Pin M to RJ 45 8 Pin Straight Trough Cable Wiring Straight through Cable Wiring ...

Page 10: ...e Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown Please make sure your waterproof RJ45 cables are with same pin assignment and colors as the above picture before deploying the cables into your network 2 5 M23 DC Power Connector Pin Assignment The front panel of the Industrial M1...

Page 11: ...is shown below V2 V2 V1 V1 CB M23FSF 120 M23 DC power cable pin assignment and wiring code V2 V2 V1 V1 V1 positive pin white cable V1 negative pin brown cable V2 positive pin black cable V2 negative pin yellow cable Note 1 Make sure you connect the correct power pin to your DC power source 2 The wire gauge for the power cable should be in the range of 12 24 AWG 3 The DC power input range is 12 56V...

Page 12: ...tures show how to install the device Step 1 Turn counterclockwise to remove the waterproof screw nuts of an M12 connector and power input Step 2 Insert the M12 UTP male connector into the M12 female Ethernet port of the Industrial M12 Ethernet Switch ...

Page 13: ...13 Step 3 Turn clockwise to tighten the screw nut of the M12 connector and make sure the connection is tight Step 4 Insert the M23 power female connector into the M23 male port of the power input ...

Page 14: ...Turn clockwise to tighten the screw nut of the M12 power connector Step 6 Please refer to chapter 2 2 for LED indicators Note Before connecting the DC power cord please check whether your local DC power source is stable Note Make sure to tightly close all interfaces to have waterproof effect ...

Page 15: ... need more support information please contact PLANET switch support team PLANET online FAQs http www planet com tw en support faq Switch support team mail address support planet com tw Copyright PLANET Technology Corp 2020 Contents are subject to revision without prior notice PLANET is a registered trademark of PLANET Technology Corp All other trademarks belong to their respective owners ...

Page 16: ......

Reviews: