background image

4-Port 10/11/2 100FX Fiber Port 

Industrial Fast Ethernet Switch

ISW-511 / ISW-621 Series

ISW-511T / ISW-621T Series

User's Manual

Summary of Contents for ISW-511 Series

Page 1: ...4 Port 10 100Mbps 1 2 100FX Fiber Port Industrial Fast Ethernet Switch ISW 511 ISW 621 Series ISW 511T ISW 621T Series User s Manual...

Page 2: ...to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is subject to change without notice...

Page 3: ...ed to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required t...

Page 4: ...fications 8 2 Installation 14 2 1 Product Description 14 2 1 1 Switch Front Panel 15 2 1 2 LED Indicators 17 2 1 3 Switch Upper Panel 17 2 1 4 Wiring the Power Inputs 18 2 1 5 Wiring the Fault Alarm C...

Page 5: ...s Table 27 4 2 Learning 27 4 3 Forwarding Filtering 27 4 4 Store and Forward 28 4 5 Auto negotiation 28 5 Troubleshooting 29 APPENDIX A Networking Connection 30 A 1 Switch s RJ45 Pin Assignments 30 A...

Page 6: ...air 1 2 How to Use This Manual This Industrial Fast Ethernet Switch User Manual is structured as follows Chapter 2 Installation The chapter explains the feature functionality and the physical installa...

Page 7: ...auto negotiation and 10 100Mbps half full duplex mode for each copper port High performance store and forward architecture broadcast storm control runt CRC filtering eliminates erroneous packets to o...

Page 8: ...ct Specifications Model ISW 511 ISW 511S15 Hardware Specifications Copper Ports 4 x 10 100BASE TX auto negotiation auto MDI MDI X Cable 10BASE T 2 pair UTP Cat 3 4 5 cable 100 meters max 100BASE TX 2...

Page 9: ...net 100BASE TX 100BASE FX IEEE 802 3x full duplex flow control Stability testing IEC60068 2 32 free fall IEC60068 2 27 shock IEC60068 2 6 vibration Temperature Operating 10 60 degrees C Storage 40 85...

Page 10: ...on DIN rail kit and wall mount ear Switch Specifications Switch Processing Scheme Store and Forward Address Table 2K entries Buffer 1Mbit Flow Control Back pressure for half duplex IEEE 802 3x pause f...

Page 11: ...eters max 100BASE TX 2 pair UTP Cat 5 5e 6 cable 100 meters max Fiber Optical Port 2 x 100BASE FX Cable 50 125 m fiber 62 5 125 m fiber 9 125 m fiber Mode multi mode single mode Distance 2km 15km Dime...

Page 12: ...Operating 10 60 degrees C Storage 40 85 degrees C Humidity Operating 5 to 90 Storage 5 to 90 non condensing Regulation Compliance FCC Part 15 Class A CE Model ISW 621T ISW 621TS15 ISW 621TF Hardware S...

Page 13: ...ressure for half duplex IEEE 802 3x pause frame for full duplex Switch Fabric 1 2Gbps Throughput Packet Per Second 0 89Mpps 64Bytes Standards Conformance Standards Compliance IEEE 802 3 Ethernet 10BAS...

Page 14: ...Industrial Fast Ethernet Switch can handle extremely large amounts of data in a secure topology linking to a backbone or high capacity servers The Industrial Fast Ethernet Switch has 2K MAC address ta...

Page 15: ...show their front panels P1 P2 FAULT LNK ACT 4 3 2 1 LNK ACT 10 100 TX RX 5 ISW 511 100 P1 P2 FAULT LNK ACT 4 3 2 1 TX RX TX RX 6 5 100 LNK ACT 100 LNK ACT 10 100 ISW 621 Figure 2 1 ISW 511 ISW 511S15...

Page 16: ...FAULT LNK ACT 4 3 2 1 TX RX TX RX 6 5 100 LNK ACT 100 LNK ACT 10 100 ISW 621T 6 LNK ACT 100 P1 P2 FAULT 5 LNK ACT 100 4 3 2 1 LNK ACT 10 100 ISW 621TF Figure 2 3 ISW 511T ISW 511TS15 Front Panel Figu...

Page 17: ...the network at 100Mbps Off indicates that the Switch is successfully connecting to the network at 10Mbps LNK ACT Green Fiber Optic Lit indicates the link through that port is successfully established...

Page 18: ...itch is used for two DC redundant powers input Please follow the steps below to insert the power wire 1 Insert positive negative DC power wires into contacts 1 and 2 for POWER 1 or 5 and 6 for POWER 2...

Page 19: ...dustrial Fast Ethernet Switch will detect the fault status of the power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an appl...

Page 20: ...teps for PLANET Industrial Switch and Industrial Media Converter are similar 2 2 1 Install DIN Rail Mounting The DIN Rail is screwed on the Industrial Gigabit Ethernet Switch when out of factory When...

Page 21: ...ch into the track Step 3 Check whether the DIN rail is tightly on the track Step 4 Please refer to the following procedures to remove the Industrial Fast Ethernet Switch from the track 1 2 Step 5 To r...

Page 22: ...ch loosen the screws to remove the DIN rail Step 2 Place the wall mount plate on the rear panel of the Industrial Fast Ethernet Switch Step 3 Use the screws to screw the wall mount plate on the Indust...

Page 23: ......

Page 24: ...er optic 100 100Base TX UTP Fiber Switch ISW 511TS15 ISW 511T 100 100 100 100 100 Steel Factory IP Camera IP Camera Fiber Switch IP Camera IP Camera IP Camera IP Camera Weather Station Winter season o...

Page 25: ...era Weather Station Winter season of Country ISW 621TF ISW 621TF ISW 621TF ISW 621TF ISW 621TF ISW 621TF 2km Multi mode 2km Multi mode 2km Multi mode 20km Single mode 60km Single mode 20km Single mode...

Page 26: ...Category 5 cable for Ethernet connection Step 6 Insert one side of Category 5 cables into the Industrial Fast Ethernet Switch Ethernet port RJ45 port and the other to the network devices Ethernet port...

Page 27: ...uture packets 4 3 Forwarding Filtering When one packet comes from some port of the Industrial Fast Ethernet Switch it will also check the destination address besides the source address learning The In...

Page 28: ...using conventional cabling and adapters Due to the learning function of the Industrial Fast Ethernet Switch the source address and corresponding port number of each incoming and outgoing packet are s...

Page 29: ...rregular Solution Check whether the attached device is not set to dedicated full duplex Some devices use a physical or software switch to change duplex modes Auto negotiation may not recognize this ty...

Page 30: ...nments 10 100Mbps 10 100BASE TX RJ45 Connector pin assignment Contact MDI Media Dependent Interface MDI X Media Dependent Interface Cross 1 Tx transmit Rx receive 2 Tx transmit Rx receive 3 Rx receive...

Page 31: ...5 6 7 8 SIDE 2 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown SIDE 1 S...

Page 32: ...lectromagnetic Compatibility Directive on 2004 108 EC For the evaluation regarding the EMC the following standards were applied Emission EN 55022 Class A 2006 Harmonic EN 61000 3 2 2006 Flicker EN 610...

Reviews: