background image

Trademarks 

Copyright © PLANET Technology Corp. 2006. 
Contents subject to which revision without prior notice. 
PLANET is a registered trademark of PLANET Technology Corp.    All other trademarks belong to their 
respective owners. 

Disclaimer 

PLANET Technology does not warrant that the hardware will work properly in all environments and 
applications, and makes no warranty and representation, either implied or expressed, with respect to the 
quality, performance, merchantability, or fitness for a particular purpose. 
PLANET has made every effort to ensure that this User's Manual is accurate; PLANET disclaims liability 
for any inaccuracies or omissions that may have occurred. 
Information in this User's Manual is subject to change without notice and does not represent a 
commitment on the part of PLANET. PLANET assumes no responsibility for any inaccuracies that may be 
contained in this User's Manual. PLANET makes no commitment to update or keep current the 
information in this User's Manual, and reserves the right to make improvements to this User's Manual 
and/or to the products described in this User's Manual, at any time without notice. 
If you find information in this manual that is incorrect, misleading, or incomplete, we would appreciate 
your comments and suggestions. 

FCC Warning 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant 
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial environment. This equipment generates, 
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the 
Instruction manual, may cause harmful interference to radio communications. Operation of this 
equipment in a residential area is likely to cause harmful interference in which case the user will be 
required to correct the interference at whose own expense.   

CE Mark Warning 

This is a Class A product. In a domestic environment, this product may cause radio interference, in which 
case the user may be required to take adequate measures. 

WEEE Warning 

 

To avoid the potential effects on the environment and human health as a result of the 
presence of hazardous substances in electrical and electronic equipment, end users of 
electrical and electronic equipment should understand the meaning of the crossed-out 
wheeled bin symbol. Do not dispose of WEEE as unsorted municipal waste and have 
to collect such WEEE separately. 
 

Revision 

PLANET Industrial Fast Ethernet Switch User's Manual 

FOR MODELS: ISW-500 / ISW-800 

Revision: 1.0(February.2006) 

Part No. 

EM_ISW500800v1 (

2011-AH0010-000

)

Summary of Contents for ISW-500

Page 1: ...5 8 Port Industrial Fast Ethernet Switch ISW 500 ISW 800 User s Manual ...

Page 2: ...appreciate your comments and suggestions FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energ...

Page 3: ...duct Specification 5 2 HARDWARE INSTALLATION 6 2 1 Product Description 6 2 2 Mounting Installation 9 3 NETWORK INSTALLATION 11 4 TROUBLESHOOTING 13 4 1 Incorrect connections 13 4 2 Diagnosing LED Indicators 13 Appendix A Networking Connection 15 A 1 Switch s RJ 45 Pin Assignments 15 A 2 RJ 45 cable pin assignment 15 ...

Page 4: ...terial and use them against to repack the product in case there is a need to return it to us for repair 1 2 How to Use This Manual This User Manual is structured as follows Chapter 2 HARDWARE INSTALLATION The chapter explains the functions of the Switch and how to physically install the Switch Chapter 3 NETWORK INSTALLATION The chapter explains how to install the Switch in the Network Chapter 4 TR...

Page 5: ...net port MAC address 1K 2K Memory Buffer 512Kbits 1Mbit Network Cable 10Base T 2 pair UTP STP Cat 3 4 5 cable 100Base TX 2 pair UTP STP Cat 5 cable 10Base T EIA TIA 568 100 ohm 100m LED Per port Link Activity Green Full duplex Collision Green Per unit Power 2 Green Power 1 Green Power Green Backplane 1Gbps 1 6Gbps Packet throughput ability 0 74Mpps 64bytes 5TX 1 19Mpps 64bytes 8TX Power Supply 12 ...

Page 6: ...rical surges typical of environments found on plant floors or in curb side traffic control cabinets An operating temperature range of 0 to 60 Degree C coupled with hazardous location certification Class 1 Division 2 allows the switch to be placed in almost any location The switch is packaged in a compact IP 30 standard aluminum that allows either DIN or panel mounting for efficient use of cabinet ...

Page 7: ...t 5 of ISW 500 Off No device attached Orange The port is operating in full duplex mode Blinks Collision of Packets occurs in the port FDX COL port 7 8 of ISW 800 port 5 of ISW 500 Off The port in half duplex mode or no device attached Orange The port is operating in full duplex mode Blinking Orange Collision of Packets occurs Off The port is in half duplex mode or no device is attached Green A net...

Page 8: ... Figure 2 3 shows the bottom panel of the switch Figure 2 3 ISW 500 800 Bottom Panel 2 1 5 Wiring the Power Inputs Please follow below steps to insert the power wire V V V V 1 Insert the positive and negative wires into the V and V connector on the terminal block connector 2 To tighten the wire clamp screws for preventing the DC wires to loose Power Notice The wire range of terminal block is from ...

Page 9: ...ing presented 2 2 1 DIN Rail mounting The DIN Rail is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following figure to screw the DIN Rail on the switch To hang the industrial switch follow the below steps Step1 Insert the top of DIN Rail into the track Step2 Lightly push the button of DIN Rail into the track ...

Page 10: ...escribed below Step1 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail Step2 Place the wall mount plate on the rear panel of the industrial switch Step3 Use the screws to screw the wall mount plate on the industrial switch Step4 Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall Step5 To remove the wall mount pla...

Page 11: ... on the DIN Rail track or wall please refer to the Mounting Installation section Step4 Power on the Industrial switch Please refer to the Wiring the Power Inputs section for power input The power LED on the Industrial switch will light up Please refer to the LED Indicators section for meaning of LED lights Step5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection Ste...

Page 12: ...re the connected network devices support MDI MDI X If it does not support then use the crossover category 5 Cable Step7 When all connections are all set and LED lights all show in normal the installation is complete ...

Page 13: ...rk performance A category 5 cable tester is a recommended tool for every 100Base T network installation 4 1 3 Improper Network Topologies It is important to make sure that you have a valid network topology Common topology faults include excessive cable length and too many repeaters hubs between end nodes In addition you should make sure that your network topology contains no data path loops Betwee...

Page 14: ... does not exceed 100 meters 328 feet Diagnosing LED Indicators the Switch can be easily monitored through panel indicators to assist in identifying problems which describes common problems you may encounter and where you can find possible solutions IF the power indicator does not turn on when the power cord is plugged in you may have a problem with power cord Than check for loose power connections...

Page 15: ...2 3 6 21 3 6 There are 8 wires on a standard UTP STP cable and each wire is color coded The following shows the pin allocation and color of straight cable and crossover cable connection Figure A 1 Straight Through and Crossover Cable Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network 2011 AH0010 000 ...