11
5. Recovering Back to Default Configuration
To reset the IP address to the default IP address
“192.168.0.100”
and the user password to factory default mode (default password
is
admin
), press the hardware reset button on the front panel for
about 10 seconds. After the device is rebooted, you can log in the
management Web interface within the same subnet of 192.168.0.xx
and default password. Be noted that all the previous setups will be
disappeared after the factory default reset is made.
Reset
100/1G/2.5G
10/100/1000T
LNK/ACT
LNK/ACT
100
1G/2.5G
P1
P2 Alarm
Ring R.O.
2
1
IGT-900-1T1S
LNK/ACT
LNK/ACT
10/100
1000
Reset
Reset
4
100/1G/2.5G
10/100/1000T
LNK/ACT
LNK/ACT
100
1G/2.5G
LNK/ACT
LNK/ACT
10/100
1000
P1
P2 Alarm
Ring R.O.
3
2
1
IGT-900-2T2S
Reset
Figure 5-1:
IGT-900-Series Reset Button