13. Recovering Back to Default Configuration
IP address has been changed or admin password has been forgotten –
Note
Follow all the recovering back to default configuration steps as
shown in the example.
1. Power off the Industrial Managed Switch and remove all the existing connec-
tions.
2. Use the straight RJ45 cable to connect to port 1 and port 2 in the loop topology
as shown below:
3. Power on the Industrial Managed Switch and 6 LNK/ACT LEDs will be lit.
4. Resetting Industrial Managed Switch to the factory default is done when 6 LNK/
ACT LEDs are lit again.
5. Remove the RJ45 cable from port 1 and port 2.
6. Reset the Industrial Managed Switch to Factory Default configuration. The Indus-
trial Managed Switch will then reboot and load the default settings as shown
below:
Default Username:
admin
Default Password:
admin
Default IP Address:
192.168.0.100
Default Subnet Mask:
255.255.255.0
Default Gateway:
192.168.0.254