User’s Manual of IGS-10020MT
401
Default Setting:
enable
Example:
Disable SNMP trap probe security engine ID
IGS-10020MT:/>
security
switch
snmp
trap probe security engine id disable
Security Switch SNMP Trap Security Engine ID
Description:
Set or show SNMP trap security engine ID.
Syntax:
Security Switch SNMP Trap Security Engine ID [<engineid>]
Parameters:
<engineid>
: Engine ID, the format may not be all zeros or all 'ff'H and is restricted to 5 - 32 octet string
Example:
Set the SNMP trap security engine ID
IGS-10020MT:/>
security switch
snmp
trap security engine id 800007e5017f000011
Security Switch SNMP Trap Security Name
Description:
Set or show SNMP trap security name.
Syntax:
Security Switch SNMP Trap Security Name [<security_name>]
Parameters:
<security_name>
: A string representing the security name for a principal (default: Show SNMP trap security name). The
allowed string length is (1-32), and the allowed content is ASCII characters from 33 to 126