4.4.3.7 Set pvid
This is an additional function of VLAN configuration.
This command allows assign PVID for selected port of GSW-2416SF. The correct usage is shown as below:
Set pvid [n] [m]
[n]
=1-24,
n
is the specific Port ID of GSW-2416SF.
[m] =
1-4095, 0 reserved for management purpose;
m
is allowed VLAN ID.
Default Setting:
0
To remote control the GSW-2416SF, the connect port have to set with PVID=0
The PVID setting screen in
Figure 4-24
appears. (Example: Set Port 1 with PVID=3)
Figure 4-24
PVID Configuration screen
#
Notice:
Change VLAN settings for every time, you have to
reboot
the switch to apply new settings.
4.4.3.8 Set vid
This command allows assign VLAN ID for specific VLAN Group of GSW-2416SF. The correct usage is shown as below:
Set vid [n] [m]
[n]
=1-24,
n
is the specific VLAN Group of GSW-2416SF.
[m] =
0-4095, m is allowed VLAN ID.
Default Setting:
0
The VID setting screen in
Figure 4-25
appears. (Example: Set VALN Group 2 with VLAN ID=3)
EM-GSW2416SFv1
- 27 -