APPENDIX A NETWORKING CONNECTION

 

A.1 Switch‘s RJ-45 Pin Assignments 

 

1000Mbps, 1000Base T 

Contact 

MDI 

MDI-X 

1 BI_DA+  BI_DB+ 

2 BI_DA-  BI_DB- 

3 BI_DB+  BI_DA+ 

4 BI_DC+  BI_DD+ 

5 BI_DC-  BI_DD- 

6 BI_DB-  BI_DA- 

7 BI_DD+  BI_DC+ 

8 BI_DD-  BI_DC- 

 

A.2 RJ-45 cable pin assignment 

 

The standard RJ-45 receptacle/connector

 

There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation 
and color of straight cable and crossover cable connection: 

 

Figure A-1: Straight-Through and Crossover Cable 

Please make sure your connected cables are with same pin assignment and color as above picture before deploying the 
cables into your network. 

 

 

 

Summary of Contents for GST-802

Page 1: ...User s Manual GST 802 802S GST 805A GST 806A15 806B15 GST 806A60 806B60 10 100 1000Base T to 1000Base LX SX Smart Media Converter 1...

Page 2: ...ng This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection again...

Page 3: ...1600MR R48 MC 1610MR MR48 CHASSIS INSTALLATION 10 2 3 REAL ETHERNET ENVIRONMENT APPLICATION 11 3 MANAGE THE MEDIA CONVERTER 13 3 1 DIP SWITCH CONFIGURATION 13 3 2 MANAGED MEDIA CONVERTER MODULE THROUG...

Page 4: ...ce for fiber interface and Link Pass Through function LLCF LLR The Link Loss Carry Forward LLCF function works with Link Loss Return LLR to diagnose network connections Also the LLR function can immed...

Page 5: ...ith FCC CE class A 1 4 Specification Model GST 802 GST 802S GST 805A GST 806 A15 GST 806 B15 GST 806 A60 GST 806B 60 Hardware Specification Standards IEEE 802 3 10Base T IEEE 802 3u 100Base TX IEEE 80...

Page 6: ...on fiber transceiver or SFP module LED Indicator y PWR Green y TP 1000 LINK ACT y Fiber LINK ACT DIP Switch Fiber Auto negotiation Manual LFP Disable Enable Power Consumption 3 1 Watts 10BTU maximum O...

Page 7: ...Outlook Right View there is one RJ 45 twisted Pair jack Auto MDI MDI X one fiber optic connector vary by model and six LED indicators Left View there is one DC jack for DC 5V power adapter GST 802 GST...

Page 8: ...t is successfully established Fiber LNK ACT Green Lights Blink Indicate that port is actively sending or receiving data Lights Off The link through that port is not established Lights On The link thro...

Page 9: ...nsure that there is no activity in the network Attach fiber cable from the GST 80x to the fiber network TX RX must be paired at both ends Attach a Cat 5 5e 6 UTP cable from the 10 100 1000Base T netwo...

Page 10: ...ia Converter board Step 2 Remove a blank faceplate from an empty expansion slot on the front of the chassis The GST 80x Media Con verter board can be installed in any expansion slot Step 3 Slide the G...

Page 11: ...rovides diverse fiber connect type options for different network applications It is very flexible for the GST 80x working as a standalone device or being installed in the central Web Smart Management...

Page 12: ...12 Figure 2 GST 80x FTTX application...

Page 13: ...read this chapter carefully 3 1 DIP Switch configuration The GST 80x provide DIP switch to setting fiber Auto negotiation Manual and LFP Disable Enable Please refer to the table below for more detail...

Page 14: ...Disable Enable Fiber Auto negotiation Manual Item Description Device To enable or disable per GST 80x Converter board LFP To enable or disable the LFP function from GST 80x Converter board TP AN Mode...

Page 15: ...nual Item Description Device To enable or disable per GST 80x Converter board LFP To enable or disable the LFP function from GST 80x Converter board TP AN Mode To set the UTP port runs at Auto negotia...

Page 16: ...able transmit receive bandwidth on TP Fiber port of GST 80x Item Description OAM Setting Provide OAM Configuration on GST 80x Ingress Rate Limit Define receive rate for bandwidth control from TP and F...

Page 17: ...not transmit a link signal until they receive a link signal from the opposite port The diagram below shows a typical network configuration with a good link status using GST 80X for remote connectivity...

Page 18: ...n the diagram box below the converter with LLR enabled will return a no link condition to its link partner With LLCF also default enabled the no link condition is carried forward to the switch hub whe...

Page 19: ...is correct 2 Please check the 1000Base LX SX interface from both devices run at force full duplex mode 3 Check and if the 1000Base LX SX interface of other device run at Auto negotiation mode only ple...

Page 20: ...J 45 cable pin assignment The standard RJ 45 receptacle connector There are 8 wires on a standard UTP STP cable and each wire is color coded The following shows the pin allocation and color of straigh...

Page 21: ...00 400 500 220 275 500 550 MM 62 5 50 50 5 4 5 550 1000Base LX SM 9 N A 5000 Notice 1 Consult your local dealer for more about PLANET single mode fiber connectivity 2 The Single mode port 1000Base LX...

Page 22: ...0 3 2 2000 Flicker EN 61000 3 3 1995 Immunity EN 55024 1998 ESD EN 61000 4 2 1995 RS EN 61000 4 3 1995 EFT Burst EN 61000 4 4 1995 Surge EN 61000 4 5 1995 CS EN 61000 4 6 1996 Magnetic Field EN 61000...

Page 23: ...1000 3 2 2000 Flicker EN 61000 3 3 1995 Immunity EN 55024 1998 ESD EN 61000 4 2 1995 RS EN 61000 4 3 1995 EFT Burst EN 61000 4 4 1995 Surge EN 61000 4 5 1995 CS EN 61000 4 6 1996 Magnetic Field EN 610...

Page 24: ...Class A Harmonic EN 61000 3 2 2000 Flicker EN 61000 3 3 1995 Immunity EN 55024 1998 ESD EN 61000 4 2 1995 RS EN 61000 4 3 1995 EFT Burst EN 61000 4 4 1995 Surge EN 61000 4 5 1995 CS EN 61000 4 6 1996...