Planet FSD-804P User Manual Download Page 13

 

 

- 13 - 

 

3. SWITCH OPERATION 

3.1 Address Table 

The Switch is implemented with an address table. This address table composed of many entries. Each entry is used to 
store the address information of some node in network, including MAC address, port no, etc. This information comes 
from the learning process of Ethernet Switch. 

3.2 Learning 

When one packet comes in from any port. The Switch will record the source address, port no. And the other related 
information in address table. This information will be used to decide either forwarding or filtering for future packets. 

3.3 Forwarding & Filtering 

When one packet comes from some port of the Ethernet Switching, it will also check the destination address besides 
the source address learning. The Ethernet Switching will lookup the address-table for the destination address. If not 
found, this packet will be forwarded to all the other ports except the port which this packet comes in. And these ports 
will transmit this packet to the network it connected. If found, and the destination address is located at different port 
from this packet comes in, the Ethernet Switching will forward this packet to the port where this destination address is 
located according to the information from address table. But, if the destination address is located at the same port with 
this packet comes in, then this packet will be filtered. Thereby increasing the network throughput and availability. 

3.4 Store-and-Forward 

Store-and-Forward is one type of packet-forwarding techniques.  A Store-and Forward Ethernet Switching stores the 
incoming frame in an internal buffer, do the complete error checking before transmission.  Therefore, no error packets 
occurrence, it is the best choice when a network needs efficiency and stability. 

The Ethernet Switch scans the destination address from the packet-header, searches the routing table provided for 
the incoming port and forwards the packet, only if required. The fast forwarding makes the switch attractive for 
connecting servers directly to the network, thereby increasing throughput and availability. However, the switch is most 
commonly used to segment existing hubs, which nearly always improves overall performance. An Ethernet Switching 
can be easily configured in any Ethernet network environment to significantly boost bandwidth using conventional 
cabling and adapters. 

Due to the learning function of the Ethernet switching, the source address and corresponding port number of each 
incoming and outgoing packet are stored in a routing table. This information is subsequently used to filter packets 
whose destination address is on the same segment as the source address. This confines network traffic to its 
respective domain, reducing the overall load on the network. 

The Switch performs "Store and forward" therefore, no error packets occur.  More reliably, it reduces the 
re-transmission rate.  No packet loss will occur. 

3.5 Auto-Negotiation 

The STP ports on the FSD-804P switch have built-in "Auto-negotiation". This technology automatically sets the best 
possible bandwidth when a connection is established with another network device (usually at Power On or Reset). 
Detecting the modes does this and speeds at the second of both devices are connected and capable of, both 
10Base-T and 100Base-TX devices can connect with the port in either Half- or Full-duplex mode.  

Summary of Contents for FSD-804P

Page 1: ...User s Manual FSD 804P 8 Port 10 100Mbps with 4 Port PoE Fast Ethernet Switch 1 ...

Page 2: ...rotection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the Instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case th...

Page 3: ... 3 1 ADDRESS TABLE 13 3 2 LEARNING 13 3 3 FORWARDING FILTERING 13 3 4 STORE AND FORWARD 13 3 5 AUTO NEGOTIATION 13 4 POWER OVER ETHERNET OVERVIEW 14 5 THE POE PROVISION PROCESS 16 5 1 LINE DETECTION 16 5 2 CLASSIFICATION 16 5 3 START UP 17 5 4 OPERATION 17 5 5 POWER DISCONNECTION SCENARIOS 17 6 TROUBLESHOOTING 18 APPENDIX A NETWORKING CONNECTION 19 A 1 DATA OUT POE SWITCH RJ 45 PORT PIN ASSIGNMENT...

Page 4: ...r over Ethernet theories Chapter 5 PoE power Provision Process The section explains the PoE power provision process Chapter 6 Trouble Shooting This chapter contains troubleshooting of FSD 804P Appendix This chapter contains cable information of FSD 804P 1 3 Features 8 Port 10 100Mbps Fast Ethernet ports 4 Port supports 48VDC power to PoE Powered device Hardware based 10 100Mbps auto negotiation Fl...

Page 5: ...mA Maximum Pin 1 2 3 6 Power AC 100 240V 50 60Hz Power Consumption Max 65 watts 221 BTU Dimension W x D x H 217 x 135 x 43 mm Weight 1 0 kg Power over Ethernet PoE Standard IEEE 802 3af Power over Ethernet PSE PoE Power Supply Type End Span PoE Power Output Per Port 48V DC 350mA Max 15 4 watts Power Pin Assignment 1 2 3 6 Power Budget 55 watts Standard Conformance EMI Safety FCC Class A CE Operati...

Page 6: ...ups and networks With 4 PoE interfaces the FSD 804P is ideal for small business and workgroups requiring to deploy the PoE for the wireless access points IP based surveillance camera or IP phones in any places easily efficiently and cost effective The front panel of FSD 804P provides LEDs for easy recognition of the switch operation status and troubleshooting These LED indicators display the power...

Page 7: ...ation 2 4 1 Before start up Before your installation please refer to the followings for your cabling 100Base TX All 100Base TX ports come with Auto Negotiation capability They automatically support 100Base TX and 10Base T networks Users only need to plug a working network device into one of the 100Base TX ports and then turn on the FSD 804P The port will automatically runs in 10Mbps 20Mbps 100Mbps...

Page 8: ...ction 4 in Specification Step4 Connect your Switch to 802 3af complied Power Devices PD and other network devices A Connect one end of a standard network cable to the 10 100 RJ 45 ports on the Back of the Switch B Connect the other end of the cable to the network devices such as printer servers workstations or routers etc Connection to the Switch requires UTP Category 5 network cabling with RJ 45 ...

Page 9: ...ttaching the brackets to the Switch You must use the screws supplied with the mounting brackets Damage caused to the parts by using incorrect screws would invalidate the warranty Step3 Secure the brackets tightly Step4 Follow the same steps to attach the second bracket to the opposite side Step5 After the brackets are attached to the Switch use suitable screws to securely attach the brackets to th...

Page 10: ...f the FSD 804P using Category 3 4 5 UTP STP cabling 4 Connect another switch or PC to the other port of FSD 804P by following the same process as described in Step 3 Figure 2 6 End node or Switch connection Cable distance for Switch The cable distance between the FSD 804P and PC should not exceed 100 meter for UTP STP cable Make sure the wiring is correct It can be used Category 3 4 5 cable in 10 ...

Page 11: ... system AP group for the enterprise For instance 4 camera AP can be easily installed around the corner in the company for surveillance demands or build a wireless roaming environment in the offices Without the power socket limitation the switch makes the installation of cameras or WLAN AP more easily and efficiently Figure 2 7 Department workgroup PoE Switch connection ...

Page 12: ... Campus Factory Warehouse can install the Access Point any where with no hesitation 10 12 watts IP Surveillance Enterprise Museum Campus Hospital Bank can install IP Camera without limits of install location no need electrician to install AC sockets 3 12 watts PoE Splitter PoE Splitter split the PoE 48V DC over the Ethernet cable into 5 9 12V DC power output It frees the device deployment from res...

Page 13: ...ame in an internal buffer do the complete error checking before transmission Therefore no error packets occurrence it is the best choice when a network needs efficiency and stability The Ethernet Switch scans the destination address from the packet header searches the routing table provided for the incoming port and forwards the packet only if required The fast forwarding makes the switch attracti...

Page 14: ...switch and the powered device Mid Span is tap the unused wire pairs 4 5 and 7 8 to carry power the other four is for data transmit End Span End Span device is direct connecting with power device End Span could also tap the wire 1 2 and 3 6 PoE System Architecture The specification of PoE typically requires two devices the Powered Source Equipment PSE and the Powered Device PD The PSE is either an ...

Page 15: ...oves into new offices next month The company staff has been clamoring for a wireless access point in the picnic area behind the building so they can work on their laptops through lunch but the cost of electrical power to the outside is not affordable Management asks for IP Surveillance Cameras and business access systems throughout the facility but they would rather avoid another electrician s pay...

Page 16: ...5 20 5 12 5 25 0 Startup Where the powered device will startup 42 38 Normal operation Supply power to device 36 57 25 0 60 0 5 1 Line Detection Before power is applied safety dictates that it must first be ensured that a valid PD is connected to the PSE s output This process is referred to as line detection and involves the PSE seeking a specific 25 KΩ signature resistor Detection of this signatur...

Page 17: ...disconnection of a PD from an active port When a PD is disconnected there is a danger that it will be replaced by a non PoE ready device while power is still on Imagine disconnecting a powered IP phone utilizing 48 VDC then inadvertently plugging the powered Ethernet cable into a non PoE notebook computer What s sure to follow is not a pretty picture The standard defines two means of disconnection...

Page 18: ...ation may not recognize this type of full duplex setting Why the Switch doesn t connect to the network Solution Check the LNK ACT LED on the switch Try another port on the Switch Make sure the cable is installed properly Make sure the cable is the right type Turn off the power After a while turn on power again Why I connect my PoE device to FSD 804P and it cannot power on Solution 1 Please check t...

Page 19: ...J 45 SIGNAL ASSIGNMENT 1 Output Transmit Data Power 2 Output Transmit Data Power 3 Receive Data Power 4 5 6 Receive Data Power 7 8 A 2 Switch s RJ 45 Pin Assignments Port 5 to Port 8 Contact MDI MDI X 1 1 TX 3 2 2 TX 6 3 3 RX 1 6 6 RX 2 4 5 7 8 Not used Not used A 3 RJ 45 cable pin assignment 21 3 6 1 2 3 6 21 3 6 ...

Page 20: ... Brown 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown Straight Cable SIDE 1 SIDE2 SIDE 1 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 SIDE 2 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown 1 White Orange 2 Green 3 White Orange 4 Blue 5 White Blue 6 Orange 7 White Brown 8 Brown Figure A 1 Straight Through and Crossover Cable Please...

Page 21: ...1S 12 CAM IR338 NT 5 1W LED Off 5 PLANET POE 151S 12 CAM IR338 NT 13 5W 14 3W LED On 6 PLANET VIP 155PT 3W 7 PLANET VIP 154PT 4 9W 5 6W 8 PLANET VIP 550PT 4 4 5W 9 PLANET WAP 4060PE 4 3W Standby 10 PLANET FSD 803PE 2 2W Standby 11 PLANET IVS 110 6 1W Standby 12 PLANET ICA 510 4 2W Standby 13 PLANET ICA 700 3 7W Standby 14 PLANET ICA 750 5 2W Standby 15 PLANET ICA 107P 5 1W Standby 16 PLANET ICA 31...

Page 22: ...rding the EMC the following standards were applied Emission EN 55022 1994 A1 1995 A2 1997 Class A Harmonic EN 61000 3 2 2000 Flicker EN 61000 3 3 1995 A1 2001 Immunity EN 55024 1998 ESD IEC 61000 4 2 1995 A1 1998 A2 2000 RS IEC 61000 4 3 1995 A1 1998 A2 2000 EFT Burst IEC 61000 4 4 1995 A1 2000 Surge IEC 61000 4 5 1995 A1 2000 CS IEC 61000 4 6 1996 A1 2000 Magnetic Field IEC 61000 4 8 1993 A1 2000...

Reviews: