Planet FSD-803PE User Manual Download Page 23

21

Appendix C 

Troubleshooting

1.  Power LED does not turns on?

Ans: 

The Switch supports two power sources, 12VDC and 802.3af, please check which 
kind of power system deployed.

a)  Powered from POE: please check with network administrator if the POE injec-

tor device is complied with 802.3af standard and well connected to port#1 of 
the Switch with 4-pair UTP cable within 100 meters. FSD-803PE will detect the 
signal from 802.3af POE device and response to get the 48VDC power. Con-
nect with non-802.3af complied injector to port#1 could damage the Switch 
permanently

b)  Powered from 12VDC: the Switch supports 12VDC AC adapter. Please check 

the  AC  adapter  complies  with  12V  DC  output.  Incorrect  DC  power  to  the 
Switch,  higher  voltage  could  damage  the  Switch,  and  lower  voltage  will  not 
power on the Switch.

2.  POE LED always blinking and can not boot up the Switch?

Ans:

The Switch only requires one power source, i.e. from POE or from 12V DC. By 
default, POE will be the first priority. However, if the POE device cannot provide 
sufficient power from the injector, or 12V DC power is just removed from the DC-
jack, the “POE” LED will blink.

a)  Powered from POE: please consult the network administrator if the POE device 

can provide the sufficient current or not.

b)  Powered from 12VDC then POE: please remove all the power connection, i.e. 

both DC plug and port#1. And re-connect the port#1 to force the Switch detect 
its power system again. 

3.  Performance is not good?

Ans: 

Please check the duplex setting of the Switch and the connected device, if the 
connected  device  does  not  support  Auto-Negotiation,  please  set  the  device  to 
forced half-duplex mode. Otherwise, the performance could be poor due to the 
incorrect duplex mode setting.

10-000039-000.indd

2004/8/27, �� 05:37

21

Summary of Contents for FSD-803PE

Page 1: ...ements to this User s Manual and or to the products described in this User s Manual at any time without notice If you find information in this manual that is incorrect misleading or incom plete we would appreciate your comments and suggestions FCC Warning This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limit...

Page 2: ...Unpacking and Setup 7 Chapter 3 Identifying External Components 9 Chapter 4 Connecting the Switch 11 Chapter 5 Technical Specifications 15 Appendix A RJ 45 PIN Specification 17 Appendix B Switch Operation 19 Appendix C Troubleshooting 21 10 000039 000 indd 2004 8 27 05 37 2 ...

Page 3: ...you need to install and configure the FSD 803PE Overview of this User s Manual Chapter 1 Introduction Describes the Switch and its features Chapter 2 Unpacking and Setup Helps you get started with the basic installation of the Switch Chapter 3 Identifying External Components Describes the front panel rear panel and LED indicators of the Switch Chapter 4 Connecting the Switch Tells how you can conn...

Page 4: ...2 This page is intentionally left blank 10 000039 000 indd 2004 8 27 05 37 2 ...

Page 5: ...hing technology A switch bridge Ethernet packets at the MAC address level of the Ethernet protocol transmitting among connected Ethernet or Fast Ethernet LAN segments Switching is a cost effective way of increasing the total network capacity available to users on a local area network A switch increases capacity and decreases network loading by dividing a local area network into different segments ...

Page 6: ...rt time If the remote end reply the injector with 802 3af supported signal the injector will then provide the DC current over the wire to power on the Switch Otherwise the Switch will never be turned on Features The Switch were designed for easy installation and high Performance in an environment where traffic on the network and the number of user increase continuously The Switch with their small ...

Page 7: ...e checking and error frame filtering this scheme prevents error packages from transmitting among segments NWay Auto negotiation for any port This allows for auto sensing of speed 10 100Mbps thereby providing you with automatic and flexible solutions in your network connections Flow control for any port This minimizes dropped packets by sending out col lision signals while the port s receiving buff...

Page 8: ...6 This page is intentionally left blank 10 000039 000 indd 2004 8 27 05 37 6 ...

Page 9: ...t support at least 1 5 kg for the Switch Option Confirm with the network administrator for the information of the POE device if the Switch is plan to connect with a 802 3af in line power hub or switch Option The power outlet should be within 1 82 meters 6 feet of the Switch Option Visually inspect the DC power jack and make sure that it is fully se cured to the power adapter Make sure that there i...

Page 10: ...8 This page is intentionally left blank 10 000039 000 indd 2004 8 27 05 37 8 ...

Page 11: ...technical specification section for information about the AC power input voltage Since the switch does not include a power switch plugging its power adapter into a power out let will immediately power it on POE The Switch supports two power systems 12VDC or powered from POE Port 1 supports 802 3af in line power Either power system can be deployed to the Switch at a time And 12VDC will not active i...

Page 12: ... 802 3af power supply connect with any other non standard 802 3af equipments to it may cause the Switch malfunction LED Indicators PWR This indicator lights green when the Switch is receiving power ei ther from 12VDC or from POE otherwise it is off LNK ACT This indicator light green when the port is connected to an Ethernet or Fast Ethernet station if the indicator is blinking green it will be tra...

Page 13: ...or possibilities for a PC to Switch connection The LINK ACT and 100 LED indicators light green for hookup to 100Mbs LNK ACT lights green while 100 LED off for hookup to 10Mbps speed Hub to Switch A hub 10 or 100Base TX can be connected to the Switch via a two pair Category 3 4 5 UTP STP straight or crossover cable The connection is accomplished from the hub Uplink MDI X or normal MDI port to any o...

Page 14: ...E indicator of the Switch will turns on to indicate it get the power from the remote POE injector And the Switch will start its POST Power on self test process and start to work Getting the power from central POE injector the FSD 803PE shall works without fear of remote power breakdown As soon as the local PCs also installed with UPS it shall guarantee the true un interrupted network accessing Swi...

Page 15: ...ght green for hookup to 100Mbps speed or only LNK ACT light green for hookup to 10Mbps speed Port Speed Duplex Mode After plugging the selected cable to a specific port the system uses auto negotiation to determine the transmission mode for any new twisted pair connection If the attached device does not support auto negotiation or has auto negotiation disabled an auto sensing process is initiated ...

Page 16: ...14 This page is intentionally left blank 10 000039 000 indd 2004 8 27 05 37 14 ...

Page 17: ...00 m 10BaseT 2 pair UTP Cat 3 4 5 100Base TX 2 pair UTP Cat 5 POE 4 pair UTP Cat 5 Number of Ports 8 x 10 100Mbps ports DC inputs DC jack DC 12V 1A max POE port 1 DC48V 150mA max Power Consumption 4 3watt max 14 5BTU per hour POE Port 1 Port 1 Pint contact of POE port Contact 4 5 7 8 power injection auto detect by IEEE802 3af Temperature Operating 0 50 degree C Storage 10 70degree C Humidity Opera...

Page 18: ...nd forward RAM Buffer 4M Filtering Address Table 2K entries per device Packet Filtering Forwarding Rate 10Mbps Ethernet 14 880 pps 100Mbps Fast Ethernet 148 800 pps MAC Address Learning Automatic update 10 000039 000 indd 2004 8 27 05 37 16 ...

Page 19: ...t devices without making a crossover cable The following table and diagram show the standard RJ 45 receptacle connector and their pin assignments RJ 45 Connector pin assignment Contact MDI Media Dependant Interface MDI X Media Dependant Interface Cross 1 TX transmit Rx receive 2 TX transmit Rx receive 3 Rx receive TX transmit 4 5 Not used 6 Rx receive TX transmit 7 8 Not used The standard cable RJ...

Page 20: ...e pin allocation and color of straight cable and crossover cable connection Figure A 1 Straight Through and Crossover Cable Please make sure your connected cable are with same pin assignment and color as above picture before deploying the cables into your network 10 000039 000 indd 2004 8 27 05 37 18 ...

Page 21: ...ed at the same port with this packet comes in when this packet will be filtered Thereby increasing the network throughput and availability Store and Forward Store and Forward is one type of packet forwarding techniques A Store and Forward Ethernet Switch stores the incoming frame in an internal buffer do the complete error checking before transmission Therefore no error packets occurrence it is th...

Page 22: ...network device usually at Power On or Reset This is done by detect the modes and speeds at the second of both device is connected and capable of Both 10Base T and 100Base TX devices can connect with the 100Base TX port in either Half or Full Duplex mode If attached device is 100Base TX port will set to 10Mbps no auto negotiation 10Mbps 10Mbps with auto negotiation 10 20Mbps 10Base T Full Duplex 10...

Page 23: ... not power on the Switch 2 POE LED always blinking and can not boot up the Switch Ans The Switch only requires one power source i e from POE or from 12V DC By default POE will be the first priority However if the POE device cannot provide sufficient power from the injector or 12V DC power is just removed from the DC jack the POE LED will blink a Powered from POE please consult the network administ...

Page 24: ...ll network per formance You can check the LED of the switch to diagnose the symptom Remove all the connection and plug in one by one if the LNK ACT LED is blinking all the time never stop please isolate this PC and see if the performance will goes back to normal if the reset PCs are connected back to the switch 10 000039 000 indd 2004 8 27 05 37 22 ...

Reviews: