background image

 

 

13 

Jacks: 

 

use ordinary straight -through twisted-pair cables to 
connect user machines and servers to the hub 
through them. 

 

If you need to connect another device with an MDI-X 
jack, such as another hub or an Ethernet switch, you 
should use a crossover cable, or make the 
connection using the MDI-X jack (described below). 
For more information about crossover connections.

   

Uplink 

Jack 
(MDI -II):

 

Use this jack to connect stations to the hub. This is 
MDI-II (Medium -dependent Interface, straight-wired) 
jack, which means you can connect the hub to a 
device with a MDI-X port using an ordinary 
straight-through cable, making a crossover cable 
unnecessary.

 

Note: 

 

1. The Hub is a power-required device, it means, the Hub 

will not work until it is powered. If your networked PCs 
will need to transmit data all the time, please consider 
use an UPS (Uninterrupted Power Supply) for your Hub. 
It will prevent you from network data loss. 

2. In some area, installing a surge suppression device 

may also help to protect your Hub from being damaged 
by unregulated surge or current to the Hub or the power 
adapter.  

LED Indicators   

Power 
Indicator 
(PWR)

 

This indicator lights green when the hub is receiving 
power, otherwise, it is off. 

Link/ 
Activity 

 

This indicator light green when the port is connected 
to an Ethernet or Fast Ethernet station, if the 
indicator blinking green will be transmitting or 
received data on the network. 

 

Summary of Contents for FSD-503

Page 1: ...SOHOConnect Series SW 500 SW 800 FSD 503 FSD 803 5 8 port 10 100Mbps Fast Ethernet Switch...

Page 2: ...cations Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning...

Page 3: ...Identifying External Components 11 Front Panel 11 Rear Panel 12 LED Indicators 13 Chapter 4 Connecting The Switch 15 PC to Switch 15 Hubto Switch 15 Hub without Uplink MDI II port 16 Switch to Switche...

Page 4: ...nual discusses how to install your SW 500 SW 800 FSD 503 FSD 803 5 8 port 10 100Mbps Fast Ethernet Switch Terms Usage In this guide the term Switch first letter upper case refers to your 5 8 port 10 1...

Page 5: ...panel and LED indicators of the Switch Chapter 4 Connecting The Switch Tells how you can connect the Switch to your Ethernet network Appendix A Technical Specifications Lists the technical general phy...

Page 6: ...ance Fast Ethernet solutions in the years to come 100Mbps Fast Ethernet is a new standard specified by the IEEE 802 3 LAN committee It is an extension of the 10Mbps Ethernet standard with the ability...

Page 7: ...rk beyond the 205 meter network diameter limit for 100BASE TX networks Switches supporting both traditional 10Mbps Ethernet and 100Mbps Fast Ethernet are also ideal for bridging between the existing 1...

Page 8: ...ade to Fast Ethernet in the future Ethernet workgroups can connect to the Switches now and change adapters and hubs anytime later without needing to change the Switches or reconfigure the network The...

Page 9: ...s while the port s receiving buffer is full Note that flow control is only available in half duplex mode Data forwarding rate per port is at wire speed for 100Mbps speed Data forwarding rate per port...

Page 10: ...ged please contact your local reseller for replacement Setup The setup of the Switch can be performed using the following steps The surface must support at least 1 5 Kg for the Switch The power outlet...

Page 11: ...b Both the front and rear panels are shown followed by a description of each panel feature The indicator panel is described in detail in the next chapter Front Panel The figure below shows the front p...

Page 12: ...wer adapter Check the technical specification section for information about the AC power input voltage Since the switch does not include a power switch plugging its power adapter into a power outlet w...

Page 13: ...cable making a crossover cable unnecessary Note 1 The Hub is a power required device it means the Hub will not work until it is powered If your networked PCs will need to transmit data all the time p...

Page 14: ...connected It remains OFF if an Ethernet station is connected FDX COL This LED indicator light amber when a respective port is in full duplex FDX mode Otherwise it is OFF for half duplex HDX operation...

Page 15: ...nections The following are LED indicator possibilities for a PC to Switch connection 1 The LINK ACT Speed LED indicator light green for hookup to 100Mbps speed LINK ACT light green while Speed LED off...

Page 16: ...II port If a hub is not equipped with an Uplink MDI II port connection can be made using either straight cable or crossover cable A Using straight cable When using straight cable the connection can b...

Page 17: ...ch A to any of the 10Mbps 100Mbps MDI X port of the other switch switch B or other devices 1 The LINK ACT 100 Speed LED indicators light green for hookup to 100Mbps speed or only LINK ACT light green...

Page 18: ...Topology Star Network Cables 10BASET 2 pair UTP Cat 3 4 5 100 m EIA TIA 568 100 ohm STP 100 m 100BASE TX 2 pair UTP Cat 5 100 m EIA TIA 568 100 ohm STP 100 m Number of Ports 5 8 x 10 100Mbps ports Up...

Page 19: ...nsmit Method Store and forward RAM Buffer 128K bytes Filtering Address Table Up to 1K entries per device Packet Filtering Forwarding Rate 10Mbps Ethernet 14 880 pps 100Mbps Fast Ethernet 148 800 pps M...

Page 20: ...bles show the standard RJ 45 receptacle connector and their pin assignments for the switch to network adapter card connection and the straight crossover cable for the Switch to switch hub bridge conne...

Page 21: ...ight cable and crossover cable connection Straight cable for Switch Uplink MDI II port to switch Hub or other devices connection Crossover cable for Switch MDI X port to switch hub or other network de...

Page 22: ...t comes from some port of the Ethernet Switch it will also check the destination address besides the source address learning The Ethernet Switch will lookup the address table for the destination addre...

Page 23: ...any Ethernet network environment to significantly boost bandwidth using conventional cabling and adapters Due to the learning function of the Ethernet switch the source address and corresponding port...

Page 24: ...Half or Full Duplex mode If attached device is 100Base TX port will set to 10Mbps no auto negotiation 10Mbps 10Mbps with auto negotiation 10 20Mbps 10Base T Full Duplex 100Mbps no auto negotiation 100...

Reviews: