3.3.3 Set up the workgroup and uplink to the backbone (Model:  FSD-
1600/1601)

Figure 3-3 Connection with VLAN enable

Turn on the DIP 4, the FSD-1600 soon separate the fourteen ports  (Port 1 to Port 14) into 
different group, then you can install two file servers to port 15, port 16, those fourteen 
users  shall  not  see  each  other  where  they  can  freely  access  the  information  from  the 
two file server. Or, port 15 is connect to your local server and port 16 up connect to your 
networks backbone, either 100 meters (FSD-1600) or 2 kilometers away (FSD-1601, both 
DIP 1 & 2 in ON position)

3.3.4 Set up Video/Voice Networks (Model:  FSD-1600/1601)

Some networks could have a devices like Video or Voice device like Internet Telephony 
Gateway,  the  support  of  priority  may  help  you  to  make  your  voice  or  video  in  higher 
position to get the precious networks bandwidth, for example to the Intermet.

If your Voice Gateway support ToS, you may direct turn on the DIP 9 to get the higher 
priority, or if your device or network nodes do not support you can turn on DIP 11 or DIP 
12 to have the hardware priority,

Figure 3-4 3 Voice Gateway to Switch Connection

Summary of Contents for FSD-1600

Page 1: ......

Page 2: ...ipment does cause interference to radio or television reception which can be determined by turning the equip ment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna Relocate the computing device with respect to the receiver Move the computer away from the deceiver Plug the computer into a different outlet so...

Page 3: ...he Smart Function 16 port model 9 3 2 1 TP or Fiber optic selection for FSD 1601 only 9 3 2 2 Port based VLAN 10 3 2 3 Port Trunking 10 3 2 4 IP ToS DS DiffServ VLAN Tag Based QoS 10 3 2 5 Port based priority 11 3 3 Application 11 3 3 1 Basic 100Mbps Server PCs to 10 100Mbps Switch 11 3 3 2 Connect to 100Base FX Switch Device Model FSD 801 1601 12 3 3 3 Set up the workgroup and uplink to the backb...

Page 4: ...ogy Choice of 100Base FX optic fiber ST SC interface The FSD 801 1601ST SC are also ideal to extend the network distance up to 2 kilometers away as a link to your remote backbone The Switch also provide rack mounting kits option for being installed On 10 inch or 19 inch rack to ease the placement and management effort Compact in size and designed for Plug and Play installation the Switch allows th...

Page 5: ... inch Rack Full Half Duplex capability on every TX ports total bandwidth is up to 200Mbps port Support up to 1K 8K Uni cast address Layer 2 address resolution Self Learn ing IEEE802 3x compliant full duplex flow control Back pressure half duplex flow control Runt and CRC Filtering eliminates erroneous packets to optimize the network bandwidth Provide internal power supply LED indicators for simple...

Page 6: ...00 FSD 801 LED indicators Printing Color Description Power PWR Green This indicator lights green when the Switch is receiving power otherwise it is off LNK ACT Green This indicator green when the port is connected to a either 10Mbps Ethernet or 100Mbs Fast Ethernet station If the station to which the Switch connected is powered off or if there is a problem with the link the LED will remain off And...

Page 7: ...r port or Fiber optic port can operate in one time Please power off FSD 801 before switching the share port to different con nection type DIP Switch FSD 801 Printing Description FDX default The 100Base FX fiber port of the switch is operating in full duplex mode HDX The port is operating in half duplex mode NOTE check the opposite end is using the same transmit mode before make the connection If y...

Page 8: ...tion If the station to which the Switch is connected is powered off a 10Mbps Ethernet station or if there is a problem with the link the LED will remain off FDX COL Amber Lit Full duplex operation Unlit Half duplex operation Blink indicates data collisions on the respective Ethernet segment of this port Whenever a collision is detected the respective COL indicator will briefly blink This is normal...

Page 9: ...t Trunk 0 port 1 2 3 4 ON Enable Trunk group 0 OFF Disable group 0 6 Port Trunk 1 port 5 6 7 8 ON Enable Trunk group 1 OFF Disable group 1 7 Port Trunk 2 port 9 10 11 12 ON Enable Trunk group 2 OFF Disable group 1 8 Port Trunk 3 port 13 14 15 16 ON Enable Trunk group 3 OFF Disable group 3 9 TCP IP TOS DS Diffserv Based QoS ON Enable QoS OFF Turn off the QoS 10 802 1Q VLAN Tag Priority Based Qos ON...

Page 10: ... mode Make sure the wiring is correct It can be used Category 3 4 5 cable in 10Mbps operation To reliably operate your network at 100Mbps you must use an Unshielded Twisted Pair UTP Category 5 cable or better Data Grade cabling While a Category 3 or 4 cable may initially seem to work it will soon cause data loss The fiber optic cable should be a multi mode fiber cable with 62 5 125μm or 50 125μm i...

Page 11: ...port where this destination address is located according to the information from address table But if the destination address is located at the same port with this packet comes in when this packet will be filtered Thereby increasing the network throughput and availability Store and Forward Store and Forward is one type of packet forwarding techniques A Store and Forward Ethernet Switch stores the ...

Page 12: ...e is 100Base TX port will set to 10Mbps no auto negotiation 10Mbps 10Mbps with auto negotiation 10 20Mbps 10Base T Full Duplex 100Mbps no auto negotiation 100Mbps 100Mbps with auto negotiation 100 200Mbps 100Base TX Full Duplex 3 2 The Smart Function 16 port model The FSD 1600 and FSD 1601 is with one DIP switch on the rear of the switch these ON OFF switches provides the functions as below Twiste...

Page 13: ...port trunking Port trunks will four times the bandwidth 800Mbps while connecting with another switches that also with port trunk capability Up to four groups where each group with 4 ports is allowed DIP 5 Turns on to enable trunk 0 from port 1 to port 4 DIP 6 Turns on to enable trunk 1 from port 5 to port 8 DIP 7 Turns on to enable trunk 2 from port 9 to port 12 DIP 8 Turns on to enable trunk 3 fr...

Page 14: ...ct set the related port to high priority DIP 11 DIP 12 Description ON OFF Port 1 and Port 2 are high priority ports OFF ON Port 1 4 are high priority ports ON ON Port 1 8 are high priority ports NOTE FSD 1600 1601 only support dual priority this means the priority only will be HIGH or LOW no matter which port you connected to NOTE Priority support can co work with VLAN 3 3 Application 3 3 1 Basic ...

Page 15: ...noted for the duplex mode For Hub only Half Duplex mode can be selected at the mean time the cable distance cannot exceed 412 meters For Switch or end node that works on full duplex mode the maximum distance cannot exceed 2 kilometers The pair of the connectors must be crossed ie TX RX port of the Switch should connect to RX TX Port of the device in other end Consult your local dealer for more inf...

Page 16: ... your networks backbone either 100 meters FSD 1600 or 2 kilometers away FSD 1601 both DIP 1 2 in ON position 3 3 4 Set up Video Voice Networks Model FSD 1600 1601 Some networks could have a devices like Video or Voice device like Internet Telephony Gateway the support of priority may help you to make your voice or video in higher position to get the precious networks bandwidth for example to the I...

Page 17: ...nsistent with the connecting device Check the cable connections Performance is bad Solution Check the full duplex status of the Ethernet Switch If the Ethernet Switch is set to full duplex and the partner is set to half duplex then the performance will be poor Some stations can not talk to other stations located on the other port Solution The address table may contain older information than of the...

Page 18: ... ohm STP 100 m max 100Base TX 2 pair UTP Cat 5 100 m max EIA TIA 568 100 ohm STP 100 m max 100Base FX Models FSD 4 8 1601 1 pair Multi mode optic fiber 62 5 125μm 50 125μm 2 km max Number of Ports 8 16 STP ports Models FSD 8 1601 1 ST SC fiber optic port 1300nm wavelength Hardware Physical Environmental Specification AC inputs 100 240VAC 50 60Hz Power Con sumption 15 25 watts LED Indication System...

Page 19: ...A Performance Transmission Method Store and forward Filtering Address Table 1 8K entries Packet Filtering Forwarding Rate 14 880pps per port for 10Mbps 148 800pps per port for 100Mbps MAC Address Learning Automatic update Max age fixed ...

Page 20: ...e following diagram and tables also show the standard RJ 45 receptacle connector and their pin assignments for the switch to network adapter card connection and the straight crossover cable for the Switch to switch hub bridge connection RJ 45 Connector pin assignment Contact Media Direct Interface Signal Media Direct Interface Cross 1 TX transmit Rx receive 2 TX transmit Rx receive 3 Rx receive TX...

Page 21: ...18 This page is intentionally left blank ...

Page 22: ......

Page 23: ...Part No 2010 000004 003 ...

Reviews: