Planet FGSW-2402S User Manual Download Page 1

 

 

 
 
 
 
 

Summary of Contents for FGSW-2402S

Page 1: ......

Page 2: ...y be contained in this User s Manual PLANET makes no commitment to update or keep current the information in this User s Manual and reserves the right to make improvements to this User s Manual and or to the products described in this User s Manual at any time without notice If you find information in this manual that is incorrect misleading or incomplete we would appreciate your comments and sugg...

Page 3: ...ning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Revision PLANET Switch User s Manual FOR MODELS FGSW 2402S Part No EM FG24V1 ...

Page 4: ...STALLATION 10 2 3 1 Switch Placement 10 2 3 2 Network Installation 12 3 CONFIGURATION 15 3 1 CONNECT TO PC 15 3 2 MAIN MENU 16 3 3 SUBMENU 1 DEVICE CONFIGURATION 17 3 4 SUBMENU 2 PORT CONFIGURATION 18 3 5 SUBMENU 3 PORT STATISTICS 19 3 6 SUBMENU 4 PORT BASED VLAN CONFIGURATION 21 3 7 SUBMENU 5 PORT TRUNK CONFIGURATION 22 3 8 SUBMENU 6 PORT MIRROR CONFIGURATION 23 3 9 SUBMENU 7 SYSTEM 24 3 10 SUBME...

Page 5: ...FGSW 2402S User s Manual 5 5 TROUBLESHOOTING 29 APPENDIX A 31 A 1 SWITCH S RJ 45 PIN ASSIGNMENTS 31 A 2 10 100MBPS 10 100BASE TX 31 A 3 RJ 45 CABLE PIN ASSIGNMENT 32 ...

Page 6: ...PLANET Switch series 6 This page intentionally left blank ...

Page 7: ...ng infrastructure The optional Gigabit modules can be Gigabit fiber optic SX or LX and also Fast Ethernet fiber optic up to 10 kilometers away Powered by a non blocking 9 6Gbps backplane the FGSW 2402S simplifies the task of upgrading your LAN to cater for increased bandwidth demand Equipped with a console interface the Gigabit Smart Switch can be programmed for basic switch management functions s...

Page 8: ...control using configurable 9 levels of upstream downstream restriction This couple with the flexible 100FX 1000SX LX T module options make the FGSW 2402S one of the best and most cost effective MTU switch solutions for Multi tenant service providers 1 3 Features w Complies with the IEEE802 3 IEEE802 3u IEEE802 3z and IEEE802 3ab Gigabit Ethernet standard w 24 10 100 Mbps 2 open slots 10 100 1000Mb...

Page 9: ...h module port w Support 8 group port based VLAN w Support 4 trunks per switch each aggregates up to 8 100Base TX ports into a 1600 Mbit s full duplex or 2 1000Base T SX LX ports into a 4000 Mbit s fat pipe w Port mirroring allows monitoring of the traffic across any port in real time 1 4 Specifications Hardware Specification Ports 24 10 100Base TX RJ 45 Auto MDI MDI X ports 2 open slot 1 RS 232 DB...

Page 10: ...System management Console port Aging Time 1 999 seconds disable Broadcast Storm Control Disable 6 20 Port Configuration Enable Disable port 10 100 Full Half Auto negotiation Enable Disable Flow Control Nine levels 3 6 9 12 20 40 60 80 Full Speed for transmitting TX and receiving RX rate Port Statistics Show each port s statistics data VLAN MTU VLAN Supported 1 25 uplink to 26 or 1 12 uplink to 25 ...

Page 11: ...CI Class A CISPR 22 Class A Safety CSA NRTL C 22 2 950 UL1950 TÜV GS EN60950 Immunity EN60555 2 Class A EN60555 3 Temperature Standard Operating 0 50ºC 32 122ºF Storage 40 70ºC 40 158ºF Humidity 5 to 95 Non condensing Standards IEEE 802 3 Ethernet IEEE 802 3u Fast Ethernet IEEE 802 3ab IEEE802 3z Gigabit Ethernet IEEE8023x flow control ...

Page 12: ...PLANET Switch series 6 This page intentionally left blank ...

Page 13: ...ecting any network device to the switch read this chapter carefully There are five choice of different module for expansion l 10 100 1000Mbps Ethernet Module RJ 45 copper l 1000Base SX Gigabit Ethernet Module SC MM l 1000Base LX Gigabit Ethernet Module SC SM MM l 100Base FX Fast Ethernet Module ST MM l 100Base FX Fast Ethernet Module SC MM 2 1 Front Panel The unit front panel provides a simple int...

Page 14: ...ellow Lit Full Duplex Blink Half Duplex Collision Off Half duplex or not connected 2 1 3 LED indictor for modules There are six LED indicators for modules of FGSW 2402S These modules have different LED definition when different module installed SGSW A1GT 10 100 1000Base T modules 1000 Green Lit indicate link status and connected on 1000Mbps 100 Green Lit indicate link status and connected on 100Mb...

Page 15: ...ing the switch without turning power off and on 2 2 Rear Panel The rear panel of the Switch indicates an AC inlet power socket which accepts input power from 100 to 240VAC 50 60Hz Figure 3 FGSW 2402S Switch rear panel Power Notice 1 The device is a power required device it means it will not operate till it is powered If your networks should active all the time please consider using UPS Uninterrupt...

Page 16: ... 2402S on a desktop or shelf near an AC power source Step3 Keep enough ventilation space between the switch and the surrounding objects Note When choosing a location please keep in mind the environmental restrictions discussed in Chapter 1 4 Specification Step4 Connect your FGSW 2402S to network devices A Connect one end of a standard network cable to the 10 100 RJ 45 ports on the front of the FGS...

Page 17: ... the switch with supplied screws attached to the package Figure 4 shows how to attach brackets to one side of the switch Figure 4 Attaching the brackets to the FGSW 2402S Caution You must use the screws supplied with the mounting brackets Damage caused to the parts by using incorrect screws would invalidate your warranty Step3 Secure the brackets tightly Step4 Follow the same steps to attach the s...

Page 18: ... to your switch 2 3 2 Network Installation 2 3 2 1 Connecting end node hub or switch 1 Place the Switch on a smooth surface or fasten the mounting brackets with the provided screws in a standard 19 rack 2 Connect switch or PC to one port of the Switch using Category 3 4 5 UTP STP cabling 3 Connect another switch or PC to the other port of Switch by following the same process as described in Step2 ...

Page 19: ...50 125 fiber cable in Gigabit Ethernet and 2 kilometers in Fast Ethernet full duplex Make sure the wiring is correct It can be used Category 3 4 5 cable in 10 Mbps operation To reliably operate your network at 100Mbps and 1000Mbps you must use an Unshielded Twisted Pair UTP Category 5 cable or better Data Grade cabling While a Category 3 or 4 cable may initially seem to work it will soon cause dat...

Page 20: ... in full duplex mode A valid connection is indicated when the Link LED is light The following sections describe the function of LEDs on the front panel Function the indicator LED flash up whenever there is a collision between a directly attached end node and any other node and light up steadily for Full duplex mode Figure 7 Network Backbone or Server connection FGSW 2402S FNSW 1600S GSW 1200S File...

Page 21: ...serial cable Prepare a RS 232 serial cable Attach the 9 pin female connector to the male connector on the switch Plug the other side of this cable to your PC Hyper Terminal In Windows 95 98 2000 XP launch HyperTerminal create a new connection and adjust settings as below ...

Page 22: ... you just set up and then turn on the switch See the following messages for successful connection Password The default password is admin After type the password you can see the screen as below To enter any of the sub menus simply type the number on the main menu ...

Page 23: ...ffic 3 VLAN Mode Configuration provide two methods to assign VLAN Port Based VLAN 8 VLAN groups can be assigned MTU MDU Per Port VLAN divide 1 24 port into different VLAN group 4 MTU MDU Per Port VLAN provide two different VLAN choices One Uplink MTU port 1 25 will be assign to different VLAN groups and uplink to port 26 Two Uplink MDU it will assign port 1 12 as different VLAN groups and uplink t...

Page 24: ...Configuration Entry Select 2 from Main Menu Purpose Media Speed Control on each port Default All ports assigned to one VLAN Type N to next page Type port number to enter the port configuration of each port The following screen is shown as below ...

Page 25: ...ull speed for transmitting TX 5 Rx Bandwidth Provision provide 9 levels 3 6 9 12 20 40 60 80 full speed for receiving RX 3 5 Submenu 3 Port Statistics Port Statistics Frames Rx Frame count on received good unicast frames of all priority levels Bytes Rx Octets count on received good unicast frames of priority level 1 Broadcast Rx Frame count on received good broadcast frames of all priority Multica...

Page 26: ...ction CRC Errors Events count on frames with valid size wrong FCS value and with no dribble bit Undersize Events count on received frames less than 64 byte and with valid FCS value Oversize Events count on received frames larger than 1522 1536 byte and with valid FCS value Fragments Events count on received frames less than 64 byte and wrong FCS value Jabbers Events count on carrier sense assertio...

Page 27: ...pose Port based VLAN select Default If you select MTU MDU Per Port VLAN From Device Configuration This configuration will not work Type VLAN group number to add VLAN member port on each VLAN group through the space key The screen is shown as below After set completed press Enter to save the current setting ...

Page 28: ...ult 4 Trunk groups are disable Purpose Trunk Configuration 4 trunk groups option shown as below Group1 0 Disable 1 1 5 2 1 2 5 6 3 1 2 3 4 5 6 7 8 Group2 0 Disable 1 9 13 2 9 10 13 14 3 9 10 11 12 13 14 15 16 Group3 0 Disable 1 17 21 2 17 18 21 22 3 17 18 19 20 21 22 23 24 Group4 0 Disable 1 25 26 ...

Page 29: ...oose one port to be monitored Target Port the frames duplicated from source port to this port Default disable Port Mirror Configuration 1 Mirroring 0 Disable 1 Enable choose 0 and 1 to disable or enable port mirror function 2 Mirror Port enter a port number as source port 3 Target Port enter a port number as target port ...

Page 30: ...PLANET Switch series 24 3 9 Submenu 7 System Entry Select 7 from Main Menu Purpose 1 Factory Default Setting reset the default setting value of the Switch 2 Reset provide reboot the Switch ...

Page 31: ...s Manual 25 3 10 Submenu 8 Password Entry Select 8 from Main Menu Purpose User can change password The default password is admin if you want to change it select item 8 from main menu the maximum length is 10 characters ...

Page 32: ...PLANET Switch series 26 This page intentionally left blank ...

Page 33: ... all the other ports except the port which this packet comes in And these ports will transmit this packet to the network it connected If found and the destination address is located at different port from this packet comes in the Ethernet Switching will forward this packet to the port where this destination address is located according to the information from address table But if the destination a...

Page 34: ...o filter packets whose destination address is on the same segment as the source address This confines network traffic to its respective domain reducing the overall load on the network The Switch performs Store and forward therefore no error packets occur More reliably it reduces the re transmission rate No packet loss will occur 4 5 Auto Negotiation The STP ports on the Switch have built in Auto n...

Page 35: ... cable connection and remove duplex mode of the Giga Switch Some stations can not talk to other stations located on The other port Solution The address table may contain older information than of the address table of that node Please power down to refresh the address information Performance is bad Solution Check the full duplex status of the Ethernet Switch If the Ethernet Switch is set to full du...

Page 36: ...PLANET Switch series 30 This page intentionally left blank ...

Page 37: ... BI_DB 3 BI_DB BI_DA 4 BI_DC BI_DD 5 BI_DC BI_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_DC Implicit implementation of the crossover function within a twisted pair cable or at a wiring panel while not expressly forbidden is beyond the scope of this standard A 2 10 100Mbps 10 100Base TX Contact MDI MDI X 1 TX RX 2 TX RX 3 RX TX 6 RX TX ...

Page 38: ...able and each wire is color coded The following shows the pin allocation and color of straight cable and crossover cable connection Figure A 1 Straight Through and Crossover Cable Please make sure your connected cable are with same pin assignment and color as above picture before deploying the cables into your network ...

Page 39: ...EM FG24V1 ...

Reviews: