Planet Networking & Communication POE-173 User Manual Download Page 2

- 9 -

- 10 -

- 11 -

- 12 -

- 13 -

Switch

100 meters

PoE

Power

Data

PoE PTZ

IP Camera

Ultra PoE Injector

Power

Data

AC

1000BASE-T UTP

PoE

1000BASE-T UTP with PoE

Power Line (AC)

AC

Figure 2:

  Connection to IEEE 802.3at/802.3af Powered 

Devices

1. Connect the AC power cord to 

“AC slot”

 of Ultra PoE 

Injector; the 

“POWER”

 LED will be on steadily.

2. Connect a standard network cable from switch/work-

station to 

“LAN”

 port of Ultra PoE Injector.

3. Connect the long cable to the port (PoE) of the 

remote PoE PD device.

4. Connect with IEEE 802.3at/af devices.

Once Ultra PoE Injector detects the existence of an IEEE 
802.3at/802.3af device, the ACTIVE LED indicator will 
be on steadily to show it is providing power.

Note

If the connected device is not fully 
complying with IEEE 802.3at/802.3af Power 
over Ethernet or in-line power device, the 
LED indicator of Ultra PoE Injector will not 
be on steadily.

5-3 The Ultra PoE Injector and Splitter 

Installation

Below are the steps showing how to install PLANET 
Ultra PoE Injector (POE-172 & POE-173) and Ultra PoE 
Splitter (POE-171S) in pair.

Switch

Power 12V/19V/24V

POE-171S

100 meters

Power

Data

Power

Data

PoE

Power

Data

AC

DC

Laptop

1000BASE-T UTP

PoE

1000BASE-T UTP with PoE

Power Line (AC)

AC

DC

Power Line (DC)

Ultra PoE Injector

Ultra PoE

Splitter

Figure 3:

  Topology of the Connection of Ultra PoE Injector and 

POE-171S

1. Connect the AC power cord to 

“AC slot”

 of Ultra PoE 

Injector; the 

“POWER”

 LED will be on steadily.

2. Connect a standard network cable from 

“POE”

 port 

of Ultra PoE Injector to 

“PoE In”

 port of POE-171S. 

The 

“ACTIVE”

 LED of Ultra PoE Injector and POE-in-

use LED of POE-171S will light up continuously.

3. Connect a standard network cable from switch/work-

station to 

“LAN”

 port of Ultra PoE Injector.

4. 

Connect the UTP cable in the package from 

“Ethernet”

 port of POE-171S to the RJ45 port of 

remote device.

5. Adjust proper DC power output and connect DC plug 

from 

“DC OUT”

 of POE-171S to remote device.

6. Power on the remote device and its power LED indi-

cator will remain on.

Note

Please make sure the POE-171S output 
voltage is correct before applying power 
to remote device. The POE-171S provides 
DC12V/19V/24V power output.

5-4 The Ultra PoE Injector and PoE 

Extender Installation

Below are the steps showing how to install the PLANET 
Ultra PoE Injector (POE-172 & POE-173) and 802.3at 
PoE Plus Extender (POE-E201) to extend the distance of 
networking.

802.3at

PoE Extender

Data

PoE

PoE

+

Power

Power

Data

+

Power

Data

100 meters

100 meters

200 meters

Power Line (AC)

AC

1000BASE-T UTP

PoE

1000BASE-T UTP with PoE

PoE IP Camera

Ultra PoE Injector

Figure 4:

  Topology of the Connection of Ultra PoE Injector and 

POE-E201

1. Connect the AC power cord to 

“AC slot”

 of Ultra PoE 

Injector; the 

“POWER”

 LED will be on steadily.

2. Connect a standard network cable from 

“POE”

 port 

of Ultra PoE Injector to the 

“IN”

 port of POE-E201.

3. The Ultra PoE Injector delivers both Ethernet Data 

and PoE power over UTP cable to the POE-E201 and 
the 

“ACTIVE”

 LED of Ultra PoE Injector and 

“PoE 

IN”

 LED of POE-E201 will light up continuously.

4. Connect the additional standard network cable to the 

remote 

Powered Device (PD)

 via the 

“OUT”

 port 

of POE-E201.

5. The 

“OUT”

 port is also the power injector which 

transmits DC voltage to the standard network cable 
and transfer data and power simultaneously between 
the Ultra PoE Injector and PD.

6. Once POE-E201 detects the existence of an IEEE 

802.3at/802.3af device, the 

“PoE OUT”

 LED indi-

cator will be on steadily to show it is providing power.

Note

1. If the connected device is not fully 

complying with IEEE 802.3at/802.3af 
standard or in-line power device, the 
PoE OUT LED indicator of POE-E201 will 
not be on steadily.

2. 

According to IEEE 802.3at/802.3af 
standard, the POE-E201 will not inject 
power to the cable if not connected to a 
standard IEEE 802.3at/802.3af device.

Customer Support

Thank you for purchasing PLANET products. You can 
browse our online FAQ resource at the PLANET Web site 

first  to  check  if  it  could  solve  your  issue.  If  you  need 

more support information, please contact PLANET switch 
support team.

PLANET online FAQ :
http://www.planet.com.tw/en/support/faq.php?type=2

Switch support team mail address :
[email protected]

Copyright © PLANET Technology Corp. 2016
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.  All 
other trademarks belong to their respective owners.

EC Declaration of Conformity

For the following equipment: 

*Type of Product        : Single-Port 10/100/1000Mbps Ultra PoE Injector   

*Model Number 

: POE-173, POE-172

* Produced by: 

Manufacturer‘s Name  : 

Planet Technology Corp. 

Manufacturer‘s Address    : 10F., No.96, Minquan Rd., Xindian Dist., 

 

New Taipei City 231, Taiwan (R.O.C.). 

is herewith confirmed to comply with the requirements set out in the Council Directive on the 

Approximation of the Laws of the Member States relating to Electromagnetic Compatibility 

Directive on 2004/108/EC and 2014/30/EU.   

For the evaluation regarding the EMC, the following standards were applied: 

EN55022  

(2010+AC:2011) 

EN 61000-3-2   

(2014) 

EN 61000-3-3   

(2013) 

EN55024  

(2010) 

 

IEC 61000-4-2 

(2008) 

 

IEC 61000-4-3   

(2006+A1:2007+A2:2010) 

 

IEC 61000-4-4   

(2012) 

 

IEC 61000-4-5 

(2006) 

 

IEC 61000-4-6 

(2013) 

 

IEC 61000-4-8 

(2009) 

 

IEC 61000-4-11 

(2004) 

Responsible for marking this declaration if the: 

Manufacturer 

 Authorized representative established within the EU 

Authorized representative established within the EU (if applicable): 
Company Name:   

Planet Technology Corp. 

Company Address:  10F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan 

(R.O.C.)

Person responsible for making this declaration 
Name, Surname     

Kent Kang

Position / Title :   

  Director

 Taiwan   

 27

th

May, 2016 

Place

Date

Legal Signature

PLANET TECHNOLOGY CORPORATION 

e-mail: [email protected]   http://www.planet.com.tw 

10F., No.96, Minquan Rd., Xindian Dist., New Taipei City, Taiwan, R.O.C. Tel:886-2-2219-9518 Fax:886-2-2219-9528