Time interval (sec) [0-7200]:
The default interval is 10. The value is the interval between each detected motion.
Users could adjust the parameter and level of Motion Detection Settings.
•
Sampling pixel interval [1-100]: Default value: 10
•
Detection level [1-100]: Default value: 10
•
Sensitivity level [1-100]: Default value: 80
•
Time interval (sec) [0-7200]: Default value: 10
Total four actions could be selected once the motion is detected.
Triggered Action (Multi-option)
The Administrator can specify alarm actions that will take when motion is detected. All options are listed
as follows:
•
Send Alarm Message by FTP/E-Mail
The Administrator can select whether to send an alarm message by FTP and/or E-Mail when motion is
detected.
•
Upload Image by FTP
Select this item, and the Administrator can assign a FTP site and configure various parameters as
shown in the figure below. When motion is detected, event images will be uploaded to the appointed
FTP site.
•
Upload Image by E-Mail
Select this item, and the Administrator can assign an e-mail address and configure various parameters
as shown in the figure below. When motion is detected, event images will be sent to the appointed