12
Planar Battery System BAT24SI
QUICK LINKS
GETTING STARTED
USING THE BATTERY
MAINTAINING THE BATTERY
APPENDIXES
To remove the used batteries
1
Remove the two Phillips screws
on the retaining bracket and lift
the bracket off.
2
Detach the battery cables from
the controller board.
3
Detach the battery cables from
the four battery terminals.
4
Place the battery cables to the side
and remove the used batteries.
Replacement tips
Never insert fuses into or remove
them from the battery with the load
plugged in. Doing so can cause
permanent damage to the system.
The battery system weighs about
25 pounds and is heavily weighted
toward the front. Handle it carefully.
Once the unit is completely out of
the enclosure, move it to a flat and
stable work surface to replace the
batteries.
Do not mix old and new batteries.
Replace both batteries during the
same maintenance session.
When reconnecting the battery
cables to the battery terminals,
be sure the connections match
RED-to-RED and BLACK-to-BLACK.
The battery system is a self-aligning
unit. When you return it to the
enclosure, push it all the way in.
The alignment occurs automatically.
Use only Yuasa NP 12-12 or
B&B EP 12-12 batteries.