Pre-utilisation check
Check:
-
The condition of the filler seals
-
The door closes correctly
-
The window is not damaged
-
The smoke passages are not obstructed by pieces of packaging or removable parts.
-
Make sure that all removable parts are correctly installed.
Note
: All gaskets ceramic ropes, seals, are consumable parts and must be changed on a regular
basis by the user.
Maintenance of the chimney
Very important
To avoid any accidents (chimney fire, etc.), regular maintenance should be carried out.
If the stove is regularly used, the chimney should be swept several times per year, together with
the stovepipe connection section.
Chimney Fire Safety
If the chimney catches fire, you must cut off the flue draught, close the doors and windows,
hatches and keys and call the Fire Brigade without delay.
DO NOT OPEN THE DOOR OF THE APPLIANCE (OR AIR INLET) UNDER ANY
CIRCUMSTANCES.
A professional engineer should check the chimney condition at least once per year.
Removing and replacing the flue baffle
a)
Open the front door
b)
Untight the screws holding the first baffle
c) Slide this baffle toward the back and remove it
d)
Move up the second baffle to release it from its fulcrum
e) Untight the screws holding the second baffle
f
)
Tip over the baffle downward to clear it
g
Remove the baffle
Figure 6
Replace the flue baffle in the reverse order
Authentic 50