Overview
The stove (Plamen 50) is in conformity with European EN standards 13240:2001 - 13240 / A2: 2004
/AC:2007-08
and has
marking affixed to it in accordance with the council directive EU
305/2011
.
-
Intermittent-burning heating appliance *.
-
Cast iron flue spigot for rear or top chimney connection (via a 45 °elbow).
-
Front loading door fitted with large refractory glass
-
Side windows 'Wide Vision'.
-
Large ash-pan.
-
Air wash system
-
"Easy Control" system (combustion control)
-
Optional Ø80 external air inlet.
When the air comes from the inlet there is no need to additional air inlet into the room.
Note
: The performance indicated above result from tests carried out in accordance with
standard EN 13240:2001 - 13240 / A2: 2004
/AC:2007-08
, with logs 3
0
cm length, loading
3,7
kg
/h
and
draught of 12 Pa
Drawing
Figure 1
(*) Normal condition of use which the wood is added on a layer of burning ashes
Authentic 35
N
30