Technical Data
Size / Model
DV01.1
DV01.2
DV01.3
Measuring range
0,25...10 1/min
0,16...16 l/min
1...65 1/min
Viscosity
20...4000 cSt
20...3000 cSt
20...4000 cSt
Accuracy
+/- 3% of meas.
value
+/- 0,3% of meas.
value
+/- 2,5% of meas.
value
max. operating pressure
100
bar
160 bar
max. medium temperature
80 °C
Connection
G 3/8
G 3/8
G 3/4
Resolution
5000 pulses/l
4082 pulses/l
500 pulses/l
Measuring volume
0,2 ml/puls
0,25 ml/puls
2 ml/puls
Output signal
Square wave pulses, min 0,8*U
B
Supply voltage
12...30 VDC, short-protected
Electrical connection
Plug incl. socket acc. to DIN 43650 / ISO 4400
Electrical protection
IP 65
Materials
Size / Model
DV01.1
/
DV01.3
DV01.2
Housing
Aluminium
Gear wheels
Steel
Bearings
plain bearings
St. steel ball bearings
Electrical connection
DV01_E.SAM
05.11.04
Page 3