Technical Data

Size / Model

DV01.1

DV01.2

DV01.3

Measuring range

0,25...10 1/min

0,16...16 l/min

1...65 1/min

Viscosity

20...4000 cSt

20...3000 cSt

20...4000 cSt

Accuracy

+/- 3% of meas.
value

+/- 0,3% of meas.
value

+/- 2,5% of meas.
value

max. operating pressure

100

 bar

160 bar

max. medium temperature

80 °C

Connection

G 3/8

G 3/8

G 3/4

Resolution

5000 pulses/l

4082 pulses/l

500 pulses/l

Measuring volume

0,2 ml/puls

0,25 ml/puls

2 ml/puls

Output signal

Square wave pulses, min 0,8*U

B

Supply voltage

12...30 VDC, short-protected

Electrical connection

Plug incl. socket acc. to DIN 43650 / ISO 4400

Electrical protection

IP 65

Materials

Size / Model

DV01.1 

DV01.3

DV01.2

Housing

Aluminium

Gear wheels

Steel

Bearings

plain bearings

St. steel ball bearings

Electrical connection

DV01_E.SAM