Models/Materials:

DV08.A…: 

housing: 

aluminium 6082

screw-type spindles: steel 1.4460

bearing: 

steel 1.4460

gaskets:

FKM

process connection:  aluminium (160 bar)

or steel (350 bar)

Measuring ranges:

Connec-

tion size

Measuring

range*

[l/min]

Output

frequency

at Qmax

[Hz]

Process connection

Female thread

"G"

aluminium 

Pmax. 160 bar

SAE flange

with female

thread, 

steel,

Pmax. 350

bar

G 1

1,4...140

254,5

GA25 

SAE25

G 1 1/4

3,5...350

287,4

GA32

SAE32

G 1 1/2

5,5...550

274,5

GA40A

SAE40A

G 1 1/2

8...800

277,8

GA40

SAE40

G 2

10...1000

257,3

GA50A

SAE40A

G 2

15...1500

275,7

GA50

SAE50

G 2 1/2

25...2500 

265,2

GA65

SAE65

* the maximum measuring ranges are indicated in each case. For higher 

viscosities, the full scale value of the measuring range can be adjusted 

due to the of a larger differential pressure will be lower.

Dimensions:

Female thread

SAE flange with female thread

Order Code:

Order number:                      DV08.

Screw-spindle volumetric

flow meter for highly viscous liquids

A. V. GA25. IW. 0

Material:

A  = aluminium / steel

S  = special order

Gasket:

V  = FKM (standard)

S  = special order

Measuring range / Process connection:

GA25 … SAE65 acc. to table „measuring ranges”

99  = special connection / special measuring range

Output signal (configurable on site):

IW  = pulse output (Push/Pull), cube plug

IR  = pulse output (Push/Pull), round plug M12x1

M5  = frequency converter (programmable, 0...2 kHz)

M6  = switch output (limit, programmable)

M7I  = with F/I-converter (output 4…20 mA)

M7U = with F/ U-converter (output 0…10 V)

HT = high temperature version

   round plug M12x1

Options:

0  = without

1  = high temperature version up to 150 °C, 30 cm

   detached electronics (with output HT only)

2  = encapsulated ball bearings in case of pressure

   fluctuations / -impacts

9  = please specify in plain text

Accessory: 

M12 plug connector with PVC cable: 

SM12.4

, 4-pole

2, 5 or 10 m length, 

straight or angled

Technical Data:

Max. pressure:

with thread-

connection (AL): 

160 bar

with SAE flange: 

350 bar

Medium-temperature: 

−25...+80 °C

(optional bis 150 °C)

Accuracy: 

± 1% of measured value

Repeatability:

 

± 0,25%

Medium: 

oil or other, non aggressive,

self-lubricating products

Power supply: 

10–30 VDC

Protection class:

 

IP65

Size table [mm]:

G

x1 x2 L1

L2

ØD A

B

C

M

H

E

F

G 1

20 20 220 324 88

49

57,1

27,8 12 52 80

69

G 1 1/4

22 22 285 381 103 55

66,7

31,6 14 48 94

77

G 1 1/2

24 24 340 456 138 66,5 79,4

36,5 16 58 106 89

G 2

33 35 405 553 168 77,3 96,8

44,4 20 74 135 116

G 2 1/2

35 42 475 633 203 86

123,8 58,7 24 79 166 150

PKP Prozessmesstechnik GmbH

Borsigstr. 24 • D-65205 Wiesbaden

S

 +49 (0) 6122-7055-0 • 

 +49 (0) 6122 7055-50

    [email protected] •    www.pkp.de

PKP Process Instruments Inc.

10 Brent Drive • Hudson, MA 01749

S

 +1-978-212-0006 • 

 +1-978-568-0060         

    [email protected] •    www.pkp-usa.com

Fl

ow

Summary of Contents for DV08

Page 1: ...Manual DV08 Screw spindle volumetric flow meter for highly viscous liquids PKP Prozessmesstechnik GmbH Borsigstra e 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email i...

Page 2: ...l use of insufficiently qualified personnel and unau thorized modification of the device Proper Usage The flow meters of the DV08 series are used to measure and display the flow rates of vis cous self...

Page 3: ...hall sensor located outside the flow chamber detects the screw flanks and gener ates a flow proportional frequency signal Two pulses corresponds to one revolution of the screws and thus to a certain m...

Page 4: ...ulse Pulses Litre G 1 1 4 140 13 1 76 3 G 1 3 5 350 29 0 34 5 G 1 5 5 550 48 6 20 6 G 1 8 0 800 72 0 13 9 G 2 10 0 1000 103 6 9 7 G 2 15 0 1500 133 0 7 5 G 2 25 0 2500 238 8 4 2 The push pull output I...

Page 5: ...the permanently programmed end value can be assigned to any flow value on site Programming 1 Set the maximum flow rate in the system 2 Apply a pulse of a least 0 5 s duration to pin 2 or white strand...

Page 6: ...rate in the system 2 Apply a pulse of a least 0 5 s duration to pin 2 or white strand with cable outlet e g by jumper to supply voltage or pulse from PLC Immediately after program ming the sensor swit...

Page 7: ...quency setpoint flow rate in the system 2 Apply a pulse of a least 0 5 s duration to pin 2 or white strand with cable outlet e g by jumper to supply voltage or pulse from PLC The electronics is now pr...

Page 8: ...the flow rate and the viscosity of the liquid to be measured Higher viscosities result in higher pressure loss Higher viscosities than listed here are easily possible but require a higher pumping cap...

Page 9: ...DV08 Instruction manual 04 2019 page 9...

Page 10: ...f the measured value If the flow ranges are limited to 20 80 FS the measurement erors are reduced If the medium has a vis cosity 170 m2 s the accuracy is also improved Test viscosities were 2 22 170 m...

Page 11: ...l rep resents a pre defined volume of product The flowmeter doesn t have to be taken out of the pipe system for changing the pick up system because the pick up is hermetically sealed from the medium T...

Page 12: ...h Pull cube plug IR pulse output Push Pull round plug M12x1 M5 frequency converter programmable 0 2 kHz M6 switch output limit programmable M7I with F I converter output 4 20 mA M7U with F U converter...

Page 13: ...k GmbH Borsigstr 24 D 65205 Wiesbaden S 49 0 6122 7055 0 49 0 6122 7055 50 info pkp de www pkp de PKP Process Instruments Inc 10 Brent Drive Hudson MA 01749 S 1 978 212 0006 1 978 568 0060 info pkp us...

Reviews: