45
➢
The socket is not supplied with
energy.
➢
The fuse is switched off.
➢
The voltage is too low. Compare the
data on the model plate with the data
of your energy supplier.
Light is on but motor does not work.
➢
ventilation damper blocked.
➢
motor mounting defective.
➢
remove blockage.
➢
replace motor.
Abnormal motor-smells.
➢
motor defective
➢
replace motor
Smear of oil.
➢
one-way valve is leaky
➢
connection base chimney-telescopic
chimney is leaky
➢
seal the valve
➢
seal the connection with a suitable
material
Appliance vibrates.
➢
motor not properly fixed
➢
hood not properly fixed
➢
fix motor properly
➢
fix hood properly
Insufficient extracting capacity.
➢
too much distance hood-hob
➢
too much draught because of open
doors and/or windows
➢
lower position of hood
➢
close the doors/windows
Appliance is unstable.
➢
mounting rail is not firmly fixed
➢
screws are not firmly tightened
➢
fix mounting rail properly
➢
tighten the screws
If the hood does not work properly and/or you can hear increased operating
noise, check the schedule below:
❖
Incorrect dimension of the air duct.
❖
Obstruction in the air duct.
❖
The diameter of the air duct from hood to wall-box inclusive should be
120/150 mm (s. T
ECHNICAL DATA
); otherwise the capacity of the motor may be
decreased.
❖
If you have installed a fly screen on the wall-box, the air vent may be
obstructed. Check by removing the fly screen.
❖
If the cover panel of the wall box is equipped with firm and slanted slats, the air
vent may be obstructed. Check by removing the cover panel.
❖
Install a cover panel with moveable slats, which do not obstruct the air vent.
❖
Check condition and cleanliness of the filters.
❖
Check if the air which is extracted by the hood is replaced to avoid negative
pressure.
❖
When you run your appliance in recirculating mode, check if the carbon filter
has been replaced on time (min. every 3-6 months).
❖
If the appliance has a malfunction not noted on the schedule or if you have
checked all items on the schedule but the problem still exists, please contact the