PRO Jack
:
Workshop Manual
19
Workshop Manual
Screw the tube into the body until the end of the thread with
Loctite 243
. Unscrew the tube to
align the pin with the bleeding screw.
Lock the locknut
JA-ECR-001-B
to the body with
Loctite 243
at
35N.m
with
OT-SER-193-A
.