![Pkm EB GK4-R Instruction Manual Download Page 29](http://html.mh-extra.com/html/pkm/eb-gk4-r/eb-gk4-r_instruction-manual_1561084029.webp)
29
2. Above a drawer
The electric circuit has to be cooled down by a permanent ventilation of fresh air as
depicted below. The data of the depiction has carefully to be observed. The bigger
the space between the appliance and the cupboard situated below is, the better the
appliance will work.
Your appliance needs an air inlet at its back and an air outlet at its front.
3. Above a cupboard with door
When the air outlet is situated below the hob:
An air outlet grill should be placed
between the hotplate and the door of
the cupboard. It will easily be installed
if the cross bar is small.
If the cross bar is flush-mounted rectangular or the hotplate is closed off, make
a bevelled cut for enabling the air outlet.