36
Move a screwdriver (1) slightly downwards (2) to open the box.
Connection diagram
Voltage heating elements 230V.
Any kind of connection: the safety
wire must be connected to the PE
terminal.
Recommended
type of
connection lead.
1 For 230 V earthed one-phase
connection, bridges connect 1-2-
3 terminals and 4-5 terminals
Protective ground to
H05VV-F3G4
2 For 400/230V earthed two-
phase connection, bridges
connect 2-3 terminals and 4-5
terminals
Protective ground to
H05VV-F4G2,5
3 For 400-230V earthed three-
phase connection, bridges
connect 4-5 terminals, phases in
succession 1,2 and 3, Neutral to
4-5
Protective ground to
H05VV-F5G1,5
L1=R, L2=S, L3=T
N= Earth
PE= earth wire terminal
1.
Check that the technical data of your energy supply meet the values on the
nameplate.
2.
Your domestic circuit must be equipped with an automatic circuit breaker.
3.
Do not attempt to repair the appliance yourself. Repairs carried out by