38
Fluid dynamical efficiency (FDE
hood
)
11.3
Fluid dynamical efficiency index
E
Grease separation
82.6
Grease separation index
C
Air flow at minimum speed/
standard operation
291.6
m
3
/h
(1)
Air flow at maximum speed/
standard operation
363.6
m
3
/h
(1)
Air flow during operation at intensive
or rapid operation setting
-
m
3
/h
(1)
Air pressure at best operating point (P
BEP
)
-
Pa
Connected load
107.5
W
Power consumption lighting system (W
l
)
2.5
W
Lighting efficiency (LE
hood
)
28.4
lux/Watt
Lighting efficiency index
A
Power consumption standby (P
s
)
0.00
W
Power consumption off (P
o
)
0.00
W
A-rated noise emission at minimum speed/
standard operation
56
dB
(2)
A-rated noise emission at maximum speed/
standard operation
68
dB
(2)
A-rated noise emission during operation at intensive
or rapid operation setting
-
dB
(2)
Explications:
(1) Airborne acoustical noise
According to dB(A) re 1 pW.
To determine the results, and in accordance with the requirements in relation to
the labelling of energy-related products and with regard to ecodesign requirements,
the following calculation and measurement methods were applied:
Directive of the European Parliament and of the Council 2010/30/EU;
REGULATION NO 65/2014.
Directive of the European Parliament and of the Council 2009/125/EC;
REGULATION NO 66/2014.
EN 50564 - Electrical and electronic household and office equipment.
Measurement of low power consumption
EN 60704-2-13 - Household and similar electrical appliances. Test code for the
determination of airborne acoustical noise. Particular requirements for range
hoods.
EN 61591 - Household range hoods and other cooking fume extractors -
Methods for measuring performance.