7). Do not put the filter in the dishwasher together with tableware Filters which are
blocked with food debris do not carry a guarantee. Dry the filters properly before
you reinstall them.
Replacing of the illuminant
Do not touch the illuminant with your hands. The sweat on your fingers will
reduce the operating time of your new illuminant. Use a thin cloth or a thin
glove.
1.
WARNING!
Disconnect the appliance from the energy supply.
2.
The illuminant should have cooled down before you remove it.
3.
Remove the old illuminant.
4.
Replace it by a new one of the same kind and power.
Carbon filters
Conventional carbon filters cannot be cleaned. The capacity of these filters is
limited. You can use such filters for about 3-6 months. Replace a depleted filter.
Find further information on the filter packaging.
5. Trouble shooting
MALFUNCTION
POSSIBLE CAUSE
MEASURE
The appliance does not work at all.
The plug of the appliance is not
connected to the socket.
The plug has become loose.
The socket is not supplied with
energy.
The fuse is switched off.
Check the corresponding socket by
connecting it with another appliance.
Check the fuse.
The voltage is too low. Compare the
data on the model plate with the data
of your energy supplier.
Light is on but motor does not work.
ventilation damper blocked.
motor mounting defective.
remove blockage.
replace motor.
Abnormal motor-smells.
motor defective
replace motor
Smear of oil.
one-way valve is leaky
connection base chimney-telescopic
seal the valve
seal the connection with a suitable