background image

30 

 

19 

 Wireless communication channel configuration 

 
Wireless  communication  between  NET250  devices  takes  place  on 
seleced  channels.  Normally  device  with  default  settings  uses  for 
communication  the  channel  n°1.  However,  it  is  possi ble  to  select  a 
different  channel  (from  1  to  7)  to  create  independent  wireless 
communication nets, each one operating on a different channel. 
Wireless  channel  modification  is  made  through  HyperTerminal 
Windows program, following this procedure: 
Start program from Windows start menu 
Start 

All programs

Accessories

Communications

HyperTerminal 

and assign a name to the new connection (for example: “NET250”). 
 

 

 
After that, select serial port to which NET250 will be connected (in the 
example COM6) and confirm. 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for NET250 Series

Page 1: ......

Page 2: ...reless 14 9 1 Lettura canale utilizzato 17 9 2 Modifica canale utilizzato 17 9 3 Verifica intensit segnale 18 10 Funzionamento Led 18 11 Introduction 19 12 Model identification 19 12 1 Antenna and ada...

Page 3: ...ice messa in esercizio avviene mediante Plug e con pratica connessione a morsetti dell alimentazione da 12 24 Vac dc la configurazione dei canali radio si seleziona con il software allegato alla confe...

Page 4: ...one Verticale Tipo connessione BNC maschio Cod 4000 00 004 Adattatore connettore SMA BNC femmina Cod 4000 00 006 Prolunga adattatore connettore SMA BNC femmina lunghezza 250 mm Dispositivi Opzionali 3...

Page 5: ...llazione COORDINATOR Mod NET250 2AD DEVICE Mod NET250 1AD 101 mm 71 mm 28 mm 9 39 mm Attacco a guida DIN EN50022 Din rail mounting guide EN50022 Guscio per connettore Shell for connector Cable USB L 1...

Page 6: ...6 5 Modalit di utilizzo 5 1 Modalit wireless indoor brevi distanze PERSONAL COMPUTER COORDINATOR Mod NET250 2AD USB DEVICE n 01 Mod NET250 1AD RS485 DEVICE n xx Mod NET250 1AD RS485 1 0 0 2 0 0 m t...

Page 7: ...distanze PERSONAL COMPUTER COORDINATOR Mod NET250 2AD USB DEVICE n 01 Mod NET250 1AD RS485 DEVICE n xx Mod NET250 1AD RS485 3 0 0 m t ANTENNA STILO Mod 4000 00 003 ANTENNA GROUND PLANE Mod 4000 00 005...

Page 8: ...8 6 Collegamenti elettrici 6 1 Connessione del NET250 2AD al PC USB PERSONAL COMPUTER Cable USB L 1 8 mt Cod 1620 00 062 COORDINATOR Mod NET250 2AD...

Page 9: ...2 coppie di conduttori twistati conforme alle norme EIA RS 232 422 Cavo raccomandato Belden 1419A Use shielded cable 2 twisted pair According to EIA RS 232 422 Suggested cable Belden 1419A RX TX TX R...

Page 10: ...er Device RS RS RS RS Utilizzare cavo schermato a 1 coppia di conduttori twistati conforme alle norme EIA RS 485 Cavo raccomandato Belden 9841 Use shielded cable 1 twisted pair According to EIA RS 485...

Page 11: ...rettamente dall area download dell azienda http download pixsys net DriverNET250 2AD All interno della cartella si trova il file CDM20802_Setup exe che deve essere scaricato nel pc collegato alla NET2...

Page 12: ...12 Selezionare la tabella Hardware e poi Gestione periferiche Andare nel men Porte COM e LPT e identificare a quale porta COM stato associato il driver FTDI nell esempio COM6...

Page 13: ...i dip switch Nel caso della NET250 1AD per velocit di comunicazione seriale si intende il baudrate per lo scambio dei dati tra i dispositivi collegati sulla rete RS232 o RS485 mentre nel caso della NE...

Page 14: ...creare diverse reti di comunicazione wireless indipendenti ciascuna operante su un canale diverso La modifica del canale di comunicazione wireless avviene tramite il programma HyperTerminal di Windows...

Page 15: ...stare le propriet della porta seriale come indicato dalla figura di seguito riportata Entrare nel menu File Propriet e selezionare la tab Impostazioni per modificare le propriet del programma come di...

Page 16: ...cedere alla seguente finestra ed impostare come indicato Uscire da tutte le finestre di configurazione impostare i dip switch della NET250 su 19200 bit s e collegarla al PC A questo punto il dispositi...

Page 17: ...ra n valore e canale RF n valore Canale RF 0 1 factory set 1 2 2 3 4 4 5 5 6 6 11 7 9 2 Modifica canale utilizzato Per cambiare il canale wireless RF digitare risposta OK digitare ats2 n valore Invio...

Page 18: ...valore RSSI Intensit segnale 0 Nessun segnale ricevuto 1 2 Livello di rumore variabile in funzione del sito 3 8 Livello segnale rilevato 9 Massima potenza segnale rilevato 10 Funzionamento Led All av...

Page 19: ...with an integrated protection against overvoltage Start up by plug and 12 24 Vac dc power supply on terminal blocks Configuration of radio channels can be selected with enclosed software Different an...

Page 20: ...ation Vertical Connection type Male BNC Cod 4000 00 004 SMA connector adapter female BNC Cod 4000 00 006 female SMA BNC connector adapter extension length 250 mm Optional devices 13 Technical data Siz...

Page 21: ...llation COORDINATOR Mod NET250 2AD DEVICE Mod NET250 1AD 101 mm 71 mm 28 mm 9 39 mm Attacco a guida DIN EN50022 Din rail mounting guide EN50022 Guscio per connettore Shell for connector Cable USB L 1...

Page 22: ...22 15 Operating mode 15 1 Indoor wireless mode short distances PERSONAL COMPUTER COORDINATOR Mod NET250 2AD USB DEVICE n 01 Mod NET250 1AD RS485 DEVICE n xx Mod NET250 1AD RS485 1 0 0 2 0 0 m t...

Page 23: ...stances PERSONAL COMPUTER COORDINATOR Mod NET250 2AD USB DEVICE n 01 Mod NET250 1AD RS485 DEVICE n xx Mod NET250 1AD RS485 3 0 0 m t ANTENNA STILO Mod 4000 00 003 ANTENNA GROUND PLANE Mod 4000 00 005...

Page 24: ...24 16 Electrical Wirings 16 1 Connect NET250 2AD to PC USB PERSONAL COMPUTER Cable USB L 1 8 mt Cod 1620 00 062 COORDINATOR Mod NET250 2AD...

Page 25: ...ie di conduttori twistati conforme alle norme EIA RS 232 422 Cavo raccomandato Belden 1419A Use shielded cable 2 twisted pair According to EIA RS 232 422 Suggested cable Belden 1419A RX TX TX RX GND G...

Page 26: ...ce RS RS RS RS Utilizzare cavo schermato a 1 coppia di conduttori twistati conforme alle norme EIA RS 485 Cavo raccomandato Belden 9841 Use shielded cable 1 twisted pair According to EIA RS 485 Sugges...

Page 27: ...sed CD but it is possible also to downoload it from http download pixsys net DriverNET250 2AD The folder includes also file CDM20802_Setup exe that have to be installed on PC connected to NET250 2AD A...

Page 28: ...28 Select Hardware table and after peripheral devices Go to Port COM LPT menu and identify to which COM has been associated to FTDI driver in the example COM6...

Page 29: ...ET250 1AD serial communication speed is the baudrate for the data exchange between devices connected to RS232 or RS485 net while in NET250 2AD it is the data exchange speed between the PC and the devi...

Page 30: ...from 1 to 7 to create independent wireless communication nets each one operating on a different channel Wireless channel modification is made through HyperTerminal Windows program following this proc...

Page 31: ...31 Set serial port property as indicated in the figure below Enter into File menu Property and select settings tab to modify program property as follows...

Page 32: ...SCII settings key to enter into following windows and set as indicated Esc from all configuration windows set NET250 dip switch on 19200 bit s and connect it to PC Now device is ready to enter into co...

Page 33: ...ce between value n and RF cha nnel Value n RF channel 0 1 factory set 1 2 2 3 4 4 5 5 6 6 11 7 19 2 Modification of used channel To change RF wireless channel digit answer OK digit ats2 value n Enter...

Page 34: ...n RSSI value n and s ignal intensity RSSI value n Signal intensity 0 No received signal 1 2 Noise level varying according to the location 3 8 Noticed signal level 9 Noticed signal maximum power 20 Led...

Page 35: ...35 Notes Updates...

Page 36: ...36 PIXSYS Via Tagliamento 18 30030 Mellaredo di Pianiga VE www pixsys net e mail sales pixsys net support pixsys net Software Rev 1 00 2300 10 133 RevA 261010 2300 10 133...

Reviews: