1.3 Size & Weight
PMC-600 Power feeding module
Dimension: (CO) 133 (W) x 195 (D) x 43(H) (mm)
(RT)122 (W) x 164 (D) x 43(H)
Weight: Approx (CO) 786 ± 2g,
(RT) 636 ± 2g
Material: metal
CO
RT
1.4 Connectors
and
Switches
(1) Power Input
¾
PMC-600/
AC 90~240V
。
CAUTION!: Be sure to follow the specified power requirement to avoid damaging
the equipment.
(2) Dip Switch Settings
DIP
Switch #
Function ON
Position
OFF
Position
1
Master/Slave CPE
CO
2
Transmission
Fast Mode
Interleave mode
3
Rate Limit
No Limit
Limited
4
SNR
6 dB
9 dB
DIP 1
:
CO, CPE switch
CO: PMC module acts as Central Office (CO) side.
CPE: PMC module acts as Customer Premises Equipment (APE) side.
DIP2: Impulse noise protection
Interleave mode: Provides communication protection for up to 250ms impulse
noise with latency of less than 6 ms.
Fast mode: Direct data transmission with latency of less than 1ms.
DIP 3: Rate limit control
Limited: Line rate limited to 50/20 Mbps.
No limit: Provides up to 100Mbps/60Mbps line rate in short line.
DIP 4: General protection