PixelRange pixelsmart User Manual Download Page 1

1

General set up

1

  Mount the fixture in the required position. The integral yoke can 

act as a floor stand or hanger.

 Important

•  When suspended off ground, always use a safety wire rated to 

a minimum of 45Kg (100lbs) through a corner hole of the yoke. 

2

  Where external control is to be used, connect a DMX lead (XLR 

5-pin female) to the input socket on the underside of the fixture. 

When suspended 

off ground, always 

use a safety wire 

rated to a minimum 

of 45Kg (100lbs) 

through one of the 

corner holes in the 

yoke.

3

  Where other fixtures are to be used in a control daisy-chain, 

connect a DMX lead (XLR 5-pin male) to the output socket on the 

underside of the fixture. 

Connect power to the fixture using a Neutrik

®

 PowerCon

®

 

connector. Insert the connector and twist it clockwise until 

 

it clicks into place.

 

Important

•   If power daisy-chaining fixtures, do not exceed a total load of 

3kW in a single daisy chain (subject to supply and cabling 

restrictions). Maximum power requirement per fixture: 185 Watts. 

See also the ‘Start up (peak)’ note on page 7.

5

  Use the control panel to access the internal menu and choose the 

appropriate operation mode and related settings (see over).   

DMX in (XLR 5pin  

male) connector

Fuse holder

DMX out  

(XLR 5pin  

female)  

connector

PixelSmart

Version 1.64 R11 firmware

Operation modes

The PixelSmart provides a range of operation modes. These are 

selected using the 

MODE

 section of the control menu: 

DMX

 

Allows RGBWW control via DMX input. Internal chase 

 

effects are not available within this mode.

MANU

  Provides RGBWW colour mixing independently of any 

external control. Use the internal control menu  

(

MAN

 section) to select the required colour values.  

EF M

  Allows the display of the dual internal chase effects, 

independently of any external control. Use the internal 

control menu (

PROG

 section) to select the required 

chase effects, speeds and cross fades. 

4+E

 

Provides control of RGBW mixing and selection of the 

dual internal chase effects via DMX input. Requires 12 

DMX channels.

5+E

 

Provides control of RGBWW mixing and selection of 

the dual internal chase effects via DMX input. Requires 

13 DMX channels.

61+E

  Provides control of individual RGBWW emitter mixing 

and selection of the dual internal chase effects via DMX 

input. Requires 69 DMX channels.

16bt

  Allows RGBWW control via DMX input, using two 8bit 

channels per colour. Internal chase effects are not avail-

able within this mode.

Factory reset 

(perform this prior to new use)

To clear previous settings: At the rear panel, press the middle 

two buttons ( 

 and   

) while the current address and mode 

are being displayed. The four digit display will show 

FACT

 then 

SET

 to indicate that the fixture has been returned to its default 

condition. This is useful to remove any settings that might cause 

confusion in a new configuration (e.g. master intensity settings).

Power in socket

Connector required: 

Neutrik

®

 PowerCon

®

 

(NAC3FCA)

 

Power out socket

Connector required: 

Neutrik

®

 PowerCon

®

 

(NAC3FCB)

 

Summary of Contents for pixelsmart

Page 1: ...g the MODE section of the control menu DMX Allows RGBWW control via DMX input Internal chase effects are not available within this mode MANU Provides RGBWW colour mixing independently of any external...

Page 2: ...operation will revert to the previously set mode at the next power on Press to exit from a menu option and eventually exit the menu completely General notes Ensure that only one DMX device in the cha...

Page 3: ...and16bt modes only When set ON this enables 16 bit master intensity control 2 x 8 bit channels For 8 bit control use the high channel alone see channel layouts DMX mode only When set oN allows you to...

Page 4: ...units where the 3 o clock position is now upright PERS MAP 09CK For units where the 9 o clock position is now upright PERS MAP 06CK For inverted units where the 6 o clock position is now upright Dimm...

Page 5: ...on The16bt mode does not use chase effects The first channel of the fixture occurs at the DMX address selected using addr and suc cessive channels for the fixture follow from there Channel 16BT 16Bt 1...

Page 6: ...reate the potential for confusion See page 1 for details of how to perform a factory reset No response during DMX control If live DMX is connected the right hand decimal point on the display should fl...

Page 7: ...irst power up and lasts only for a period measured in microseconds Approvals Miscellaneous Enclosure rating IP20 not protected against moisture ingress Control input USITT DMX512 input connector pin o...

Reviews: