![Piusi SQUALO35 Manual Download Page 11](http://html.mh-extra.com/html/piusi/squalo35/squalo35_manual_1560391011.webp)
29
/124
29
/124
This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
(translated from italian)
SUBMERSIBLE PUMP
EN
11 INSTALLATION
ATTENTION
The pump must never be operated before the delivery lines have been con-
nected.
Installation is an operation that may be of some complexity. It must be car-
ried out by qualified and authorized installers.
Make sure that there is no danger of toxic fumes or harmful gases in the
working atmosphere. In case of welding operations use all precautions to
avoid explosions.
Keep in mind the danger of infection and the hygiene and sanitary precau-
tionary rules.
PRELIMINARY
INSPECTION
- Verify that all components are present. Request any missing parts from the
manufacturer.
- Check that the pump has not suffered any damage during transport or storage.
- Carefully clean the delivery outlet, removing any dust or other packaging
material that may be present.
- Check that the electrical data corresponds to those indicated on the data plate.
WARNING
Authorised
installation
personnel
All installations must be carried out by authorised and competent personnel
only. Authorised persons must
- ensure the correct installation of equipment required for the correct func-
tioning of the pump;
- only use accessories that have been supplied with the system.
ATTENTION
The use of accessories that are unsuitable and were not provided with the
system is strictly prohibited. Piusi S.p.A. accepts no responsibility for dam-
age to persons, property or the environment caused by failure to comply
with this requirement.
THE PUMP IS FOR PROFESSIONAL USE ONLY.
Motors are not explosion-proof. DO NOT install the system in places with
danger of explosion.
ISO 22241 provides the AUS32 (DEF, AdBlue®) requirements including:
1) quality of AUS32 (DEF, AdBlue®) solution,
2) applicable test methods,
3) packaging transportation and storage requirements and
4) refilling interface requirements.
AUS32 (DEF, AdBlue®) solution must be:
- HANDLED AND STORED IN COMPATIBLE MATERIAL;
- KEPT FREE OF CONTAMINATION;
- STORED AT TEMPERATURES THAT WILL NOT CAUSE THE SOLUTION
TO DETERIORATE.
The use of contaminated or out of specification AUS32 (DEF, AdBlue®) can
cause filter problems, clogged injectors, deterioration of the selective cat-
alytic reduction process, or poison the vehicle’s catalytic converter used in
the exhaust system.
AUS32 (DEF, AdBlue®) manufacturers may require a system inspection to
insure that all components are AUS32 (DEF, AdBlue®) compatible and that
the tank and system have been properly cleaned, rinsed, and flushed be-
fore AUS32 (DEF, AdBlue®) is delivered.