17
17
/48
EN
This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
MC
BOX
1.5 ETL
Translated from Italian
TECHNICAL SPECIFICATIONS
9.
9.1
PERMITTED USES
Implementation of a fluid dispensing system, intended for private use, not subject to special
regulations (eg ATEX) for potentially explosive environments
9.2
CONTROL SYSTEM PERFORMANCE
The performance of the
MC 1.5
control system is detailed in the manual of electronic parts
and software
9.3
METERING PRECISION
Mainly influenced by used pulsation type
For further details, please refer to the specific user manual for used pulsation type
9.4
Technical data
Maximum acceptable variations from the electrical parameters are:
¦
v/- 10%
for AC versions
;
¦ fre/- 1%
(+/-2% for short periods)
MC BOX 1.5 ETL
Nominal power supply voltage
90-240 Vac
Nominal frequency (Hz)
50/60Hz
Max current draw in stand-by at ambient T 25°C
20 mA @230Vac
40 mA @110 Vac
Electronic control card power line fuse
1 A T (del)
Max motor current
15 A
Motor line fuse
1
fuse 20 A T (del)