Pittsburgh Modular structure 344 Manual Download Page 21

21

 

Summary of Contents for structure 344

Page 1: ...pittsburgh modular synthesizers structure 344 manual...

Page 2: ...2...

Page 3: ...ything we have learned in the past 8 years designing and building eurorack cases I would like to thank Steve Rightnour of Monorocket for helping Pittsburgh Modular get started many years ago Steve s k...

Page 4: ...Structure 344 Please contact Pittsburgh Modular regarding malfunctions of any kind Only use the IEC power adapter provided by Pittsburgh Modular with the Structure 344 Using an incorrect power adapte...

Page 5: ...2 5 Utility Bridge Internal Signal Routing Map 14 6 Individual Utility Bridge Sections 16 7 Utility Bridge Preamp 18 8 Utility Bridge Mix Mult 20 9 Utility Bridge Voltage Controlled Mixer Bus 22 10 Ut...

Page 6: ...ck Selected bus signal output Bus Mixer 25 Or Output Jack Analog or mix of Bus A and Bus B 26 And Output Jack Mix of Bus A and Bus B 27 Inverted Output Jack Inverted mix of Bus A and Bus B Bus Outputs...

Page 7: ...7...

Page 8: ...4 Bus Outputs 5 Voltage Controlled Mixer Bus B 6 Signal Attenuators The sections were selected to enhance the functionality of attached eurorack modules by including a deep set of tools that will be...

Page 9: ...9...

Page 10: ...10...

Page 11: ...of CV trimmers An attenuator knob starts at zero signal when turned full left and at full right it is outputting the full signal level The zero point for an attenuverter knob is at 12 o clock Turning...

Page 12: ...cut when a patch cable is inserted A simple example would be Input 1 of Voltage Controlled Mixer Bus A Internally the output of Input 1 is sent to the Voltage Controlled Mixer where it is mixed with...

Page 13: ...13...

Page 14: ...14...

Page 15: ...nt from the Input 1 output 15 to the Voltage Controlled Mixer Bus A outputs c Voltage Controlled Mixer Bus B Input 1 Output Input 1 signal 35 sent from the Input 1 output 36 to the Voltage Controlled...

Page 16: ...16 6 Individual Utility Bridge Sections The Utility Bridge is comprised of 6 individual function sections The following pages will explain the features of these sections...

Page 17: ...17...

Page 18: ...18...

Page 19: ...30x gain with integrated soft clipping overdrive Perfect for processing external signals or overdriving internal waveforms Preamp Patching Notes The preamp can be used to raise the signal level of lin...

Page 20: ...al individually buffered copies of the incoming audio or CV signal s The Mix Mult is perfect for pitch sensitive CV signals Mix Mult Patching Notes The Mix Mult works great for both audio and CV signa...

Page 21: ...21...

Page 22: ...22...

Page 23: ...t 1 no signal patched in Input 1 is normaled to 5v allowing for adjustable DC offset The Input 1 Attenuverter Knob 10 is used to adjust this voltage anywhere from 5v Input 1 knob full left to 0v Input...

Page 24: ...ion Voltage Controlled Mixer Bus Patching Notes The normalized voltage 5v to 5v can be used as a DC offset source by patching out of Output 1 12 This removes Input 1 from the mixer allowing Input 2 an...

Page 25: ...25...

Page 26: ...26...

Page 27: ...tion of Bus A and Bus B The center of the Bus Outputs section combines Bus A and Bus B in 3 different ways The Or Output uses an analog logic process to output the highest positive voltage from either...

Page 28: ...ion controls Input 1 44 is normaled to Input 2 47 so if no cable is patched into Input 2 47 the signal from Input 1 44 is used Signal Attenuator Patching Notes One of the signal attenuators can be use...

Page 29: ...29...

Page 30: ...30...

Page 31: ...er and switch on the case Carefully test each module to ensure it is working properly Adding and Removing Eurorack Modules Notes WARNING ALWAYS TURN OFF AND UNPLUG THE CASE BEFORE ADDING OR REMOVING M...

Page 32: ...enclosures offer industry leading power and the Structure 344 is no exception The Structure 344 power supplies are rated at 5 amps of 12v power and 5 amps of 12v power with 5 06v line regulation unde...

Page 33: ...33...

Page 34: ...34 14 Service and Other Information Please contact us for service or other information related to the Structure 344 or any other Pittsburgh Modular product www pittsburghmodular com contact...

Page 35: ...ed by accident mishandled altered improperly serviced or repaired by the customer where such treatment has affected its performance or reliability This includes but is not limited to damage related to...

Page 36: ...36...

Reviews: