J693
47
5.2.2
Advanced Entry Calibration
The second calibration method is the Advanced Entry Calibration. This method
overrides all previous calibration settings and should be used only when the
Standard Calibration method has failed. The procedure has two parts:
1) Sensor Gain: Different algorithms are used for sampling, to produce
different measurements for the media.
2) Sensor Levels: At a selected gain, values are directly input for ‘Paper’,
‘Mark’ or ‘Gap’, and ‘Empty’ variables.
To perform an Advanced Entry Calibration:
Step
Operator Action
Displayed Message
Comment
1
Turn ‘On’ the printer.
"
2
Press the
key to enter
Menu Mode.
Raise the printhead
assembly for visual access
to the Media Sensor and
media.
"
See Section
4.0.2 for
details.
3
Press the
key to
enter the Media Settings
menu.
"
"
See Section
4.1.1 for
details.
4
Press the key.
"
See Section
4.1.1 for
details.
5
Press the key. Use
the key to scroll to
the desired sensor type and
press the
key to
enable the selection.
J"
See Section
4.1.1 for
details.
The enabled
selection will
be indicated
with an *
.
(Continued next page)