coils out of circuit with an Ohm Meter, the resistance
should correspond to the chart below, if the resistance
varies more than 5 Ohm the element will need to be
changed. Also check for continuity to ground on each
end of the suspect element, there should be no continuity
to ground.

208 volt elements

18.5 Ohms

220 volt elements

20.7 Ohms

240 volt elements

24.6 Ohms

Safety (Side On) Contactor:

Check the coil with an Ohm Meter, the resistance should
be approximately 3 - 6 Ohms out of circuit. If it does not
have this resistance it should be changed.

Relay Board:

Note:

 J connectors are marked on the relay board.

•With 24 VAC supplied to pin #2 at connector J35 and a
good F1 fuse, the relay board will have a 24 VAC output
at pin #2 on connectors J33 and J34  and the A.C. indi-
cator will be illuminated.

Note: If the fryer is equipped with a computer or
solid state digital, at connection J33 there will be a
jumper from pin #2 to pin #10 to supply 24 VAC to
pin # 2 at connection J31 to supply the controller
with 24VAC.

•When the board receives a 24 VDC side on input at pin
#7 on connectors J31 or J33, the S.O. indicator will illu-
minate, the side on relay (S.O.) will energize and there
will be a 24 VAC output at pin #4 on connector J32.
•When the board receives a 24 VDC heat demand input
at pin #6 on connectors J31 or J33, the H.D. indicator
will illuminate, the heat demand relay (H.D.) will energize
and there will be continuity between pin #1 and pin #2 at
connector J32.

Computer Control:

Note:

 All controller test points are at connector P/J1 (clos-

est connector to the controller).

•With 24 VAC supplied to pin #1(24VAC supply) and
pin # 5(24VAC input from DVI), the display should read
"OFF".
•With the controller turned on, there will be a 24 VDC
output at pin #9 (side on).

•When the controller calls for heat, there will be a 24 VDC
output at pin #8 (heat demand) and a 24 VAC input at pin
#6 (heat feed back). If the controller does not receive the
24 VAC input at pin #6 in approximately 90 seconds, the
controller will display "HEAT FAIL" or "IGNITION FAIL-
URE". This would indicate a break in the heat demand or
heat feed back circuit.

1. Check the hi-limit switch (is it open or tripped).
2. Check the ignition module (sensing pilot flame,
locked out, 24 VAC at MV terminal).
3. Check the heat demand relay (H.D.) on the relay
board (is heat demand relay energized, continuity
through COM and NO contacts).

•If display reads "PROBE OP" "OPEN", ohm test the tem-
perature probe. Check the wires and connectors between
the probe and controller for continuity.
•If display reads "SYSTEM" "FAILURE", test the tem-
perature probe and the wires and connectors between the
probe and controller for a short.
•If display reads "DRAINING" "TURN OFF", verify that
the drain valve is closed, check the proximity switch on the
drain valve, turn the fryer off, then turn the fryer on.

Digital Solid State Control:

Note:

 All controller test points are at connector P/J1 (clos-

est connector to the controller).

•With 24 VAC supplied to pin #1(24VAC supply) and pin
# 5(24VAC input from DVI), the display should read
"OFF".
•With the controller turned on, there will be a 24 VDC
output at pin #9 (side on).
•When the controller calls for heat, the display will read
"HEAt", there will be a 24 VDC output at pin #8 (heat
demand) and a 24 VAC input at pin #6 (heat feed back).
If the controller does not receive the 24 VAC input at pin
#6 in approximately 90 seconds, the controller will display
"HEAt" "FAIL" . This would indicate a break in the heat
demand or heat feed back circuit.

1. Check the hi-limit switch (is it open or tripped).
2. Check the ignition module (sensing pilot flame,
locked out, 24 VAC at MV terminal).
3. Check the heat demand relay (H.D.) on the relay
board (is heat demand relay energized, continuity
through COM and NO contacts).

•If display reads "Prob", ohm test the temperature probe.
Check the wires and connectors between the probe and
controller for continuity.

Summary of Contents for SEH50

Page 1: ...and Exploded Parts For Electric Fryers Covering Models SEH50 Full and Split Pitco Frialator Inc P O Box501 JctI 89 I 93Concord NH03302 0501 509Route3A Bow NH03304 800 258 3708 603 225 6684 FAX 603 225 8497 www pitco com FRANCAIS US CAN GB ...

Page 2: ...RVICE TECHNICIAN THE MODEL SERIAL NUMBER AND ELECTRICAL REQUIREMENTS STAMPED INTO THE DATA PLATE LOCATED ON THE INSIDE PANEL OF THE DOOR NOTICE THISAPPLIANCE IS INTENDED FOR PROFESSIONAL USE ONLY ANDAS SUCH SHOULD BE OPERATED BY FULLY TRAINED PERSONNEL NOTICE IT IS RECOMMENDED THAT THIS MACHINE BE INSPECTED BYAQUALIFIED TECHNICIAN ONAYEARLY BASIS WARNING THE POWER SUPPLY MUST BE DISCONNECTED SERVI...

Page 3: ...Chart 4 Basic Trouble Shooting 6 Relay Board Component Explanation 8 Reserved for Ladder Diagram 11 Reserved for Schematics 12 25 Basic Parts List 27 Exploded Drawings 28 37 Element and Tank Components 28 Pump Box and Drain Manifold 30 Main Entrance Box 32 Pump Assembly and Filter Pan 34 Wire Harness 36 US CAN GB ...

Page 4: ...F 20 F the computer will have to be turned off and back on for the unit to heat Filter System Opening the RED return valve handle will close the proximityswitchcausingthe pumprun relayto beenergized Thepumpmotorwillbegintorun Closingthereturnvalvehandlewillde energizethe relayandthepumpmotorwillstoprunning Thepumpsystemisequippedwithacircuitbreaker whichwillde energizethesystemandtheheattape in th...

Page 5: ...istor to simulate a 230 F 275 F temperature This will cause the elementstoheatcontinuouslyuntilthehi limittripsorthe fryeristurnedoff If the fryer is equipped with a computer or digital controller plug the resistor in at connector J41 behindthefrontpanel If the fryer is equipped with a solid state controllerbehind the door plug the resistor in at connector J43 behind the front panel If the switch ...

Page 6: ...n 8 heat demand and a 24VAC input at pin 6 heat feed back If the controller does not receive the 24VAC input at pin 6 in approximately 90 seconds the controllerwilldisplay HEATFAIL or IGNITIONFAIL URE This would indicate a break in the heat demand or heat feed back circuit 1 Check the hi limit switch is it open or tripped 2 Check the ignition module sensing pilot flame locked out 24VAC at MVtermin...

Page 7: ...d the controller Ifnoneoftheindicatorsilluminatewhenthecontrolleris turnedon verifythatthedrainvalveisclosedandthatthe magnetic proximity switch has continuity when the drain valve is closed Also verify that there is 24VAC at pin 1 24 VAC supply and pin 5 24VAC input from DVI Backup Solid State Control The backup solid state control works the same as the pri marysolidstatecontrol withtheexceptiono...

Page 8: ...efective D Check input power Repair or call a qualified electrician Oil is hotter or colder than computer controller displays A Temperature calibration B Probe C Probe wiring terminals A Adjust temperature offset up to 10 F B Check replace if defective C Clean or repair terminals Computer displays DRAINING or TURN OFF A Blue drain valve not fully closed B Sensor switch C Incorrect switch gap align...

Page 9: ...Sensor switch C Incorrect switch gap alignment A Check position of handle B Switch may be loose or have loose wires replace if defective C Check gap alignment replace if defective Oil is returning to the vat slowly or not at all A Dirty filter paper B Strainer cap dirty C Filter pan not pushed in completely D O rings not sealing on pick up tube A Change filter paper B Remove strainer cap and clean...

Page 10: ...nput voltage from transformer Relay Board Note Note If the fryer is equipped with a computer or solid state digital at connection J33 there will be a jumper from pin 2 to pin 10 to supply 24 VAC to pin 2 at connection J31 to supply the controller with 24VAC J connectors are marked on the relay board With 24 VAC supplied to pin 2 at connector J35 and a good F1 fuse the relay board will have a 24 VA...

Page 11: ...ND ENABLE HEAT DEMAND TO DRAIN OR FLOAT SWITCH 24VACH 1 3 NONE BASKET LIFT R BASKET LIFT L SIDE ON DC HEAT DEMAND 24VDC RETURN 24VAC RETURN HEAT FEEDBACK 6 2 4 5 7 8 10 9 TEMPERATURE TO PRIMARY COOKING CONTROLLER FUSE SIDE ON K3 K1 HEAT DEMAND HEAT FEED BACK 24VACH POWER 24VACN RETURN DRAIN OR FLOAT SWITCH 24VAC POWER SWITCHED HEAT DEMAND NONE NONE SIDE ON DC RETURN NONE NONE 7 DC COMMON BASKET LI...

Page 12: ...10 L22 238 Rev 1 08 03 Schematics ...

Page 13: ...DBACK INPUT 24 VAC INPUT 24 VAC COMMON 24 VAC RELAY BOARD SIDE ON HEAT DEMAND HEAT DEMAND CONTACTOR SIDE ON CONTACTOR F1 FUSE TRANSFORMER AC SO HD 24 VAC COMMON HI LIMIT SWITCH DOMESTIC ONLY DRAIN SWITCH NO NC NO NC HI LIMIT RESET 24 VAC COMMON 24 VAC TO TRANSFORMER TO HI LIMIT SWITCH CONNECTOR CE EXPORT ONLY ...

Page 14: ...12 L22 238 Rev 1 08 03 ...

Page 15: ...13 L22 238 Rev 1 08 03 ...

Page 16: ...14 L22 238 Rev 1 08 03 ...

Page 17: ...15 L22 238 Rev 1 08 03 ...

Page 18: ...16 L22 238 Rev 1 08 03 ...

Page 19: ...17 L22 238 Rev 1 08 03 ...

Page 20: ...18 L22 238 Rev 1 08 03 ...

Page 21: ...19 L22 238 Rev 1 08 03 ...

Page 22: ...20 L22 238 Rev 1 08 03 ...

Page 23: ...21 L22 238 Rev 1 08 03 ...

Page 24: ...22 L22 238 Rev 1 08 03 ...

Page 25: ...23 L22 238 Rev 1 08 03 ...

Page 26: ...24 L22 238 Rev 1 08 03 ...

Page 27: ...25 L22 238 Rev 1 08 03 ...

Page 28: ...26 L22 238 Rev 0 08 03 Exploded Drawings and Parts Lists ...

Page 29: ...aker 208 240V 60130301 120 24V Transformer 60130302 230 240 24V Transformer 60130303 208 24V Transformer PP11058 24VAC SPST Relay 120V 60104701 24VAC DPDT Relay 208 240V 60132701 0 2A Time Delay Fuse 60133503 120V Heat Tape Pump 60133504 230 240V Heat Tape Pump 60133501 120V Heat Tape Flush Hose 60133502 230 240V Heat Tape Flush Hose PP11104 1 Viton O ring 60138701 Full LH Non Locking Drain Valve ...

Page 30: ... Element 230V 50006612 Element 240V 50006613 Element 480V 4 60088003 Bolt Element 1 4 x20x3 4 SS 5 60141201 Hi Limit Switch 6 A3342902 Lower Hi Limit Bracket 7 PP11366 Screw 10 24 X 5 8 PHH SS TF 8 A3342802 Upper Hi Limit Bracket 9 PP10665 Screw 10 24 X 3 8 10 B6700605 C Temperature Probe 11 A3342504 Rear Probe Bracket 12 A4108302 Splash Back 13 A3342502 Front Probe Bracket 14 60138101 Basket Hang...

Page 31: ...29 L22 238 Rev 0 08 03 Figure 1 ...

Page 32: ...Non locking Handle 60138703 Drain Valve Full Right Split W Locking Handle 6 A7021701 Drain Valve Nipple 7 A7022201 Drain Flange 8 A7022101 Drain Ferrule 9 B6665101 Drain Elbow 10 60088002 Hex Bolt 3 8 x16x1 1 4 11 P0082700 Lock Washer 3 8 12 60127701 Drain Line Clamp 13 60059302 Drain Line Gasket 14 B6664701 Drain Down Spout Full Full B6673301 Drain Down Spout Split 15 60138702 Drain Valve Left Sp...

Page 33: ...31 L22 238 Rev 0 08 03 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Pump Entrance Box viewed from bottom Figure 2 ...

Page 34: ...60127301 Relay Board 60132901 Relay Board Insulation 3 P5047301 3 Post Terminal Block 4 60139201 Heat Demand Contactor 5 PP10560 Side On Contactor 6 PP10429 Transformer 120 208 240VAC 7 60140701 Rcpt 10A 250V IE320F Screw In 8 P5045282 4 Post Terminal Block 9 B5305001 DVI Return Switch PP10263 DVI Return Actuator not shown ...

Page 35: ...33 L22 238 Rev 0 08 03 1 2 3 4 5 6 7 8 9 4 2 4 5 6 3 Figure 3 ...

Page 36: ...VAC Motor Only PP10417 5 GPM Pump Only 11 P6071516 3 4 x 4 NPT Nipple 12 PP11104 1 x 1 18 viton O ring 3 required 13 A7027602 Pickup Tube Receiving Block 14 P7036603 3 4 NPT Coupling 15 60132201 Hose Teflon Swivel FxMPT 16 60128008 Tbg Flex Return Line 0 5 x 15 5 60128009 Tbg Flex Return Line 0 5 x 19 60128010 Tbg Flex Return Line 0 5 x 22 60128011 Tbg Flex Return Line 0 5 x 10 17 60131801 Return ...

Page 37: ...35 L22 238 Rev 0 08 03 20 21 22 23 1 1 2 3 4 6 7 8 9 10 11 12 5 13 14 15 16 17 18 19 Figure 4 ...

Page 38: ...753701 WRG HV DELTA SGL SEH50 B6754001 WRG HV WYE DUAL SEH50 HIGH VOLTAGE HARNESSES NOT SHOWN B6752401 WRG CNTRL LFT SNGL SEH50 B6752501 WRG CNTRL RIGHT SEH50 NOT SHOWN 2X 3 0 COIL 4 5 L1 A1 A2 10 0 K10L COIL A B P35 P34 P32 J 4 3 J41 5 0 2 5 7 B 6 4 0 A 1 T1 BS1 K10L GND STRIP J 8 J 5 J7 J 4 J2 P2 2 8 4 3 5 0 4 0 2 5 9 0 24VAC 2 5 5 5 12 0 2 5 5 5 L3 3 4 2 5 2 1 10 6 2X 2X 3 0 9 5 1 10 1 B 0 5 6 ...

Page 39: ... BK 10 11 J 1 2 3 4 5 6 7 8 9 12 9 12 8 7 6 5 2 3 4 1 11 10 1 25 1 25 60 00 J1 J2 SCHEMATIC Y BK GR W BK BK R P3 BL BK BK 10 11 P2 1 2 3 4 5 6 7 8 9 12 9 12 8 7 6 5 2 3 4 1 11 10 1 25 228 00 P2 P3 4 50 50 TO REAR OF FRYER TO HOOD MOUNTED CONTROLLER 50 B6749401 CABLE EXTERNAL REMOTE B6749301 CABLE INTERNAL REMOTE GND N L GND N L 60128501 CORD FEMALE IEC NEMA 5 15 Figure 6 ...

Page 40: ...tern Standard Time Monday through Friday toll free at 800 258 3708 US and Canada only or 603 225 6680 In the event of problems with or questions about your order please contact the Pitco Frialator Autho rized Service and Parts representative ASAP covering your area through Pitco at 800 258 3708 US only 24 hours L22 238Rev0 08 03 ...

Reviews: