INSTALLATION/OPERATION

5

WARNING

During operation there is an open flame inside this appliance. The unit may get hot

enough to set near by materials on fire. Keep the area around the appliance free from

combustibles.

Lighting Instructions

For manual pilots, refer to the following instructions.

WARNING

If pilot extinguishes, wait 5 minutes before attempting to relight the pilot to allow any built

up gas to dissipate.

a. 

Open gas supply valves to the appliance.

b. 

Turn the thermostat control knob counterclockwise to the OFF position.

c. 

Turn the gas valve knob counterclockwise to the PILOT position. Push knob
in and hold a flame to the pilot until the pilot ignites; this may take a little while
the first time you light the pilot because of the air in the lines. Once lit, hold
the knob in for approximately one minute and then release.

d. 

If the pilot goes out, wait 5 minutes and repeat step C. If after three tries the
pilot will not remain lit, refer to the operator troubleshooting section of this
manual.

e. 

Once a pilot flame has been established, turn the gas valve knob
counterclockwise to the ON position.

f. 

Set the thermostat control knob to the desired temperature setting, The main
burners will ignite and be controlled by the thermostat.

Pilot Flame Adjustment

For manual pilots, refer to the following instructions. Perform this procedure once the pilot is lit and
ensure that the thermostat is turned to the OFF position.

NOTE: This procedure requires a DC millivolt meter set to a scale of 0-1000 mV.
             Using test leads with sharp probes will help in taking the required readings.

a.  Locate the thermopile wires coming from the pilot to the

gas valve.

b.  Using the positive (+) test probe, connect the probe to

the top PP terminal with the red wire.

c.  Connect the negative (-) test probe to the bottom PP

terminal with the white wire.

d.  The output level should be 550mv ± 50mV. If this level

is not correct, remove the cap screw and adjust the
screw in and out to achieve the proper millivolt level.
Replace cap screw.

Note: Allow 3 to 5 minutes between flame adjustments to allow the reading to stabilize.

Summary of Contents for L20-299

Page 1: ...mplete this information and retain this manual for the life of the equipment Model ________________________ Serial ________________________ Date Purchased __________________ Installation and Operation...

Page 2: ...appliance equipped with casters and a flexible gas line must be connected to the gas supply with a quick disconnect device This quick disconnect must comply with ANSI Z24 41 To limit the movement of t...

Page 3: ...Systems 4 Lighting Instructions 5 Pilot Flame Adjustment 5 Main Burner System Adjustment 6 Initial Cleaning 7 OPERATION 8 Filling the Tank 8 Filling the tank with liquid shortening oil 8 Filling the t...

Page 4: ...This appliance must be installed with legs or casters it cannot be curb mounted Curb mounting will seriously inhibit this appliances ability to effect proper combustion WARNING This appliance must be...

Page 5: ...essary for servicing and proper burner operation Ensure that you meet the minimum clearance requirements specified in this manual Installation Clearances The clearances shown below are for combustible...

Page 6: ...from the fuel line If the fuel line is to be tested at a pressure equal to or less than PSIG 3 45 kPa the appliance can be connected during the test but the unit s gas valve must be shut Test all gas...

Page 7: ...sulting increased flow of air through the combustion system will cause improper operation poor temperature recovery poor ignition and could extinguish the pilot Initial Adjustments After your applianc...

Page 8: ...fer to the operator troubleshooting section of this manual e Once a pilot flame has been established turn the gas valve knob counterclockwise to the ON position f Set the thermostat control knob to th...

Page 9: ...re tap plug and connect an accurate pressure gauge range of 0 16 w c in 0 1 increments or manometer b Turn on this and all appliances connected to the gas supply line and light their main burners The...

Page 10: ...er let the water level go below the OIL LEVEL mark stamped on the tank c Using the cleaning brush scrub the inside of the tank to remove the protective coating d When cleaning is complete turn the app...

Page 11: ...the rack covering the tubes tube rack b Cut the solid shortening oil into cubes no larger than one inch ALWAYS pack the shortening oil below between and on top of the burner tubes DO NOT leave any lar...

Page 12: ...bility of the appliances main burners to operate Complete shutdown turns off the gas supply to the appliance STANDBY Turn the thermostat to the OFF position Turn the gas valve knob clockwise to the PI...

Page 13: ...boiling If you have water in the tank you will need to drain it dry it and fill it with shortening oil Follow the filling instructions in this manual To check the calibration of your appliance refer t...

Page 14: ...e Turn the adjustment screw until the burners come on at 325 F 163 F f Replace the knob and allow the appliance to cycle 4 to 6 times Check the temperature of the digital thermometer against the therm...

Page 15: ...foaming and boil over c Allow the appliance to soak for 20 minutes to soften shortening oil deposits Use the cleaning brush to scrub and remove any residue from the tank tubes and side walls d When f...

Page 16: ...TROUBLESHOOTING Basic Troubleshooting Flow Chart Refer to this section to correct common problems that may be encountered during the course of normal operation If applicable a schematic is provided o...

Page 17: ...WIRING DIAGRAM 14 WIRING DIAGRAM...

Page 18: ...15 THIS PAGE LEFT INTENTIONALLY BLANK...

Page 19: ...16 THIS PAGE LEFT INTENTIONALLY BLANK...

Page 20: ...Installation and Operation Manual Covering Model 65 Series Fryer with Millivolt Gas Valve THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE L20 299 Rev 0 06 06...

Reviews: