10. Fire Protection

Distance from flammable structures and furniture

A minimum distance from combustible materials is required to ensure adequate thermal protection:

KORPI ECO ja KIPINÄ ECO: 40 cm at the back and 40 cm at the sides, 80 cm at the front and 150 cm at the top.

Minimum distanc

es from flammable structures and furniture are stated on heater’s label and must be observed.

Heater

For solid fuel heaters floor in front of fireplace’s door made of flammable materials must be protected by a non

-flammable

hearth. Its minimum dimensions are 40 cm (50 cm recommended) in the front and 10 cm on the sides of fireplace.

11. Spare Parts

Only spare parts approved or provided by the manufacturer may be used. For inquiries, please, contact a specialized vendor.

No modifications to heater are allowed!

12. Warning in case of fire in chimney

Deposit in chimney may catch fire if unsuitable or humid fuel is used. In such case close all heater air holes immediately and
call the fire brigade. After fire is extinguished chimney should be inspected by an expert for cracks or untight places.

13. Nominal heating capacity, combustion air adjustment, and fuel burning time

Nominal heating capacity of heater is 6.5 kW and it is obtained at minimum supply pressure of 12 Pa:

Fuel 

Wood logs (17 cm length, average 8 cm) 

Lignite briquettes 

Maximum dose 

1.9 kg 

1.6 kg 

Primary air slider 

Closed 

Open at 50 % 

Secondary air slider lower 

Open at 40 % 

Open at 70 % 

Secondary air slider upper 

Open at 50 % 

Open at 70 % 

Burning time 

1 hour 

1 hour 

The primary air slider is located on the bottom door. The secondary air slider is up on the door. 

14. Space Heating Capacity

For rooms with insulation non-conform with calorific insulation regulations space heating capacity should be determined
pursuant to DIN 18 893 for nominal heating capacity of 6.5 kW:

in favourable heating conditions: 

124 m³ 

in moderate heating conditions:   

73 m³ 

in unfavourable heating conditions: 

48 m³ 

15. Technical Data

Capacity:

6.5 kW 

Weight:

DEEP FOREST ECO = 70 kg, SPARKS ECO = 75 kg 

Upper flue gas outlet:

Ø 117/120 mm (inner / outer diameter)

16. Chimney connection

Data for chimney properties calculation (at nominal heating capacity):

Fuel 

Wood logs 

Lignite briquettes 

Flue gas flow [gs

-1

4.9 

7.9 

Average temperature of flue after draught shaft [°C] 

308 

278 

Summary of Contents for HTT DEEP FOREST ECO

Page 1: ...This product is not suitable as the main heat source for heating PISLA HTT DEEP FOREST ECO SPARKS ECO Installation and Operation Manual tested according to the standard EN 13240 ...

Page 2: ......

Page 3: ...PISLA HTT DEEP FOREST ECO SPARKS ECO PISLA OY Teollisuustie 6 8 FI 44500 VIITASAARI 358 10 843 210 www pisla fi ...

Page 4: ...may cause increased emissions When lighting the stove the primary air slider must be fully open It is advisable to light the fire with paper wood chips and smaller firewood Add more fuel as soon as firing fuel catches fire Do never use alcohol petrol or other flammable liquids for firing Do always use some paper wood chips and a small amount of fuel for that Make sure that primary and secondary ai...

Page 5: ...ch fire if unsuitable or humid fuel is used In such case close all heater air holes immediately and call the fire brigade After fire is extinguished chimney should be inspected by an expert for cracks or untight places 13 Nominal heating capacity combustion air adjustment and fuel burning time Nominal heating capacity of heater is 6 5 kW and it is obtained at minimum supply pressure of 12 Pa Fuel ...

Page 6: ...on code of the product type Solid fuel equipment without hot water supply EN 13240 2001 A2 2004 AC 2007 2 Type series or serial number or other element allowing identification of the construction products Stoves for solid fuel type designation DEEP FOREST ECO and SPARKS ECO designed for continual operation classification of the stove 1 according to Table 1 EN 13240 A2 Basic technical data of stove...

Page 7: ...ARKS ECO ceiling 1500 front 800 Risk of burning fuel falling Requirement fulfilled The emissions CO wood 0 05 brown coal briquettes 0 09 CO mg Nm3 wood 630 brown coal briquettes 1110 Dust mg Nm3 wood 35 brown coal briquettes 33 OGC mg Nm3 wood 24 brown coal briquettes 49 NOx mg Nm3 wood 104 brown coal briquettes 187 The surface temperature Requirement fulfilled Electrical safety NPD Clean ability ...

Page 8: ...PISLA HTT DEEP FOREST ECO SPARKS ECO PISLA OY Teollisuustie 6 8 FI 44500 VIITASAARI 358 10 843 210 www pisla fi Pisla HTT Deep Forest Eco ...

Page 9: ...PISLA HTT DEEP FOREST ECO SPARKS ECO PISLA OY Teollisuustie 6 8 FI 44500 VIITASAARI 358 10 843 210 www pisla fi Pisla HTT Sparks Eco ...

Page 10: ......

Page 11: ......

Page 12: ......

Reviews: