PISCO VG Series Manual Download Page 17

39

7. Instructions for Tube Disconnection

① Make sure there is no air pressure inside of the tube, before disconnecting it.
② Push the release-ring of the push-in fitting evenly and deeply enough to 

pull out the tube toward oneself. By insufficient pushing of the release-
ring, the tube may not be pulled out or damaged by scratch, and tube 
shavings may remain inside of the fitting, which may cause the leakage 
later.

8. Instructions for Installing a fitting

① When installing a fitting, use proper tools to tighten a hexagonal-column 

or an inner hexagonal socket. When inserting a hex key into the inner 
hexagonal  socket  of  the  fitting,  be  careful  so  that  the  tool  does  not 
touch  lock-claws.  The  deformation  of  lock-claws  may  result  in  a  poor 
performance of systems or an escape of the tube.

② Refer to Table 2 which shows the recommended tightening torque. Do 

not exceed these limits to tighten a thread. Excessive tightening may 
break the thread part or deform the gasket and cause a fluid leakage. 
Tightening  thread  with  tightening  torque  lower  than  these  limits  may 
cause a loosened thread or a fluid leakage.

③  Adjust  the  tube  direction  while  tightening  thread  within  these  limits, 

since some PISCO products are not rotatable after the installation.

●Table  2:    Recommended  tightening  torque  /  Sealock  color  /  Gasket 

materials

Thread type

Thread size

Tightening torque

Sealock color

Gasket materials

Metric thread

M3

×

0.5

0.7N

·

m

SUS304

NBR

M5

×

0.8

1.0 ~ 1.5N

·

m

M6

×

1

2 ~ 2.7N

·

m

M3

×

0.5

0.5 ~ 0.6N

·

m

POM

M5

×

0.8

1 ~ 1.5N

·

m

M6

×

0.75

0.8 ~ 1N

·

m

M8

×

0.75

1 ~ 2N

·

m

Taper pipe thread

R1/8

7 ~ 9N

·

m

White

R1/4

12 ~ 14N

·

m

R3/8

22 ~ 24N

·

m

R1/2

28 ~ 30N

·

m

Unified thread

No.10-32UNF

1.0 ~ 1.5N

·

m

SUS304

NBR

National pipe 

thread taper

1/16-27NPT

7 ~ 9N

·

m

White

1/8-27NPT

7 ~ 9N

·

m

1/4-18NPT

12 ~ 14N

·

m

3/8-18NPT

22 ~ 24N

·

m

1/2-14NPT

28 ~ 30N

·

m

※ These values may differ for some products. Refer to each specification as well.

9. Instructions for removing a fitting

① When removing a fitting, use proper tools to loosen a hexagonal-column 

or an inner hex bolt.

②  Remove  the  sealant  stuck  on  the  mating  equipment.  The  remained 

sealant may get into the peripheral equipment and cause malfunctions.

10.  Arrange  piping  avoiding  any  load  on  fittings  and  tubes  such  as  twist, 

tensile,  moment  load,  shaking  and  physical  impact.  These  may  cause 
damages to fittings, tube deformations, bursting and the escape of tubes.

S

afety 

I

nstructions

Summary of Contents for VG Series

Page 1: ...acuum switch and blow off valve are united Select the best combination in accordance with applications There are 3 output types 1 switch output and 1 analog output type 2 point switch output type and cost saving 1 analog output type Air supply port P Valve unit Suction valve Blow off valve Vacuum port V Blow off air rate adjustment needle Ejector unit Vacuum switch Filter ...

Page 2: ... 5mm 0 7mm 1 0mm H type Vacuum level Suction flow 90kPa 7l min ANR 93kPa 13l min ANR 93kPa 27l min ANR L type Vacuum level Suction flow 66kPa 12l min ANR 66kPa 26l min ANR 66kPa 40l min ANR E type Vacuum level Suction flow 90kPa 10 5l min ANR 90kPa 21l min ANR Air consumption 11 5l min ANR 23l min ANR 17l min ANR 46l min ANR 34l min ANR Supply pressure is 0 5MPa for H and L type and 0 35MPa for E ...

Page 3: ...24VDC supplied Fluid medium Operating pressure range Proof pressure Operating temp range Operating humidity range Durability No ofpressuresetting Switch output Pressuresettingrange Switch output Operating accuracy Differentialresponse Switch capacity Residual voltage Output voltage Analog output Zero point voltage Span voltage Lin HYS DC12 24V 10 24VDC Ripple P P Max 10 Variable about 1 15 of set ...

Page 4: ...GE07 Vacuum characteristics Flow characteristics 0 10 20 30 40 50 40 H ty pe E ty pe L t y p e H type Final vacuum L t y p e F i n a l v a c u u m E t y p e F in a l v a c u u m H type suction flow E type suction flow L type suction flow Air consumption Supply pressure 0 5MPa H L type 0 35MPa E type 0 0 10 20 30 40 13 26 40 53 66 80 93 13 26 40 53 66 80 93 0 1 0 2 0 3 0 4 0 5 0 6 Supply pressure M...

Page 5: ...the elastic sleeve seals around the tube Refer to 2 Instructions for Tube Insertion under Common Safety Instructions for Fittings Tube disconnection The tube is disconnected by pushing release ring to release Lock claws Make sure to stop air supply before the tube disconnection 2 How to fix the product In order to fix the vacuum generator VG tighten M3 threads through the fixing holes on the resin...

Page 6: ...h digital type Built in Filter Type Unit combination Suction Valve Blow off Valve Built in Filter Type Unit combination Vacuum Switch digital type Suction Valve Blow off Valve Built in Filter Polyurethane Tube Piping products catalog P 596 Polyurethane Tube is for the general pneumatic piping and suitable for a compact piping Nylon Tube Piping products catalog P 608 Nylon Tube is for the general p...

Page 7: ...nal vacuum kPa Suction flow l min ANR Air consumption l min ANR Weight g CAD file name VGH05A 44 4 9 6 9 1 10 9 0 5 90 7 11 5 47 VVG 001 VGH07A 66 6 12 1 11 6 11 7 0 7 93 13 23 49 VGH10A 66 1 27 46 48 VGL05A 44 4 9 6 9 1 10 9 0 5 66 12 11 5 46 VGL07A 66 6 12 1 11 6 11 7 0 7 26 23 48 VGL10A 66 1 40 46 47 VGE07A 66 6 12 1 11 6 11 7 0 7 90 10 5 17 48 VGE10A 66 1 21 34 Unit mm Model code Tube O D øD L...

Page 8: ...mm Model code Tube O D øD L1 L2 C Nozzle Bore mm Final vacuum kPa Suction flow l min ANR Air consumption l min ANR Weight g CAD file name VGH05E 44 L 4 9 6 7 6 10 9 0 5 90 7 11 5 99 VVG 001 VGH07E 66 L 6 12 1 10 1 11 7 0 7 93 13 23 100 VGH10E 66 L 1 27 46 101 VGL05E 44 L 4 9 6 7 6 10 9 0 5 66 12 11 5 99 VGL07E 66 L 6 12 1 10 1 11 7 0 7 26 23 101 VGL10E 66 L 1 40 46 100 VGE07E 66 L 6 12 1 10 1 11 7...

Page 9: ...Operation indicator LED and Vacuum Setting Trimmer Vacuum Sensor digital type Suction Pilot Valve Blow off Valve Built in Filter Type Cable lead out direction Side Vacuum Air source F L Type F S Type CAD 2D Chart P 109 CAD 2D Chart P 109 Unit mm Model code Tube O D øD L1 L2 C Nozzle Bore mm Final vacuum kPa Suction flow l min ANR Air consumption l min ANR Weight g CAD file name VGH05F 44 L 4 9 6 7...

Page 10: ...nning of the generator is carried out the total operation time per day is longer than non operation time Replacement Element Remove the fixing screws to replace filter elements Make sure not to lose the filter seal ring after the replacement and tighten the screws with tightening torque 0 18 0 22Nm Silencer cover Filter cover Filter element Model code VGFE10 Filter unit Vacuum sensor Valve unit as...

Page 11: ...e setting Vacuum sensor with analog output Code NA only Differential response setting can be adjusted by the hysteresis setting trimmer HYS Differential response setting range is regulated within about 0 15 of the set value Differential response setting becomes large when the trimmer is turned in the clockwise direction Confirmation of Hysteresis Gradually increase and decrease the supply pressure...

Page 12: ...eriously impair the performance of the vacuum generator Supply a stable DC power to the product Add a surge absorption circuit to relays or solenoid valves etc which are to be connected with output terminal and source terminal Avoid any use which involves over 80mA in current Ground FG terminal when using a unit power source such as switching current Output terminals lead wire color black and gray...

Page 13: ...f PISCO products and constitute all systems based on the latest catalog or information considering any malfunctions 2 Handle the pneumatic equipment with enough knowledge and experience Improper use of compressed air is dangerous Assembly operation and maintenance of machines using pneumatic equipment should be conducted by a person with enough knowledge and experience 3 Do not operate machine equ...

Page 14: ...hird parties and intentional or accidental damages of PISCO products due to incorrect usage 3 PISCO does not take any responsibility for any loss caused by improper usage of PISCO products such as exceeding the specification limit or not following the usage the published instructions and catalog allow 4 PISCO does not take any responsibility for any loss caused by remodeling of PISCO products or b...

Page 15: ...cuit Rotary Block only The other PISCO products can be damaged in these applications 8 Use only Die Temperature Control Fitting Series Tube Fitting Stainless SUS316 Series Tube Fitting Stainless SUS316 Compression Fitting Series or Tube Fitting Brass Series under the condition of over 60 140 F water or thermal oil Other PISCO products can be damaged by heat and hydrolysis under the condition above...

Page 16: ... mm size Nylon tube Polyurethane tube inch size Nylon tube Polyurethane tube ø1 8mm 0 05mm ø1 8 0 1mm 0 15mm ø3mm 0 15mm ø5 32 0 1mm 0 15mm ø4mm 0 1mm 0 15mm ø3 16 0 1mm 0 15mm ø6mm 0 1mm 0 15mm ø1 4 0 1mm 0 15mm ø8mm 0 1mm 0 15mm ø5 16 0 1mm 0 15mm ø10mm 0 1mm 0 15mm ø3 8 0 1mm 0 15mm ø12mm 0 1mm 0 15mm ø1 2 0 1mm 0 15mm ø16mm 0 1mm 0 15mm ø5 8 0 1mm 0 15mm 6 Instructions for Tube Insertion Make ...

Page 17: ...d thread or a fluid leakage Adjust the tube direction while tightening thread within these limits since some PISCO products are not rotatable after the installation Table 2 Recommended tightening torque Sealock color Gasket materials Thread type Thread size Tightening torque Sealock color Gasket materials Metric thread M3 0 5 0 7N m SUS304 NBR M5 0 8 1 0 1 5N m M6 1 2 2 7N m M3 0 5 0 5 0 6N m POM ...

Page 18: ...hose things 7 Provide a protective cover on the products when it is exposed to sunlight 8 Carry out clogging check for silencer element in an ejector and a vacuum filter periodically Clogged element will be a cause to impair the performance or a cause of troubles 9 Before replacing the element thoroughly read and understand the method of filter replacement in the catalog 10 Make sure the correct p...

Page 19: ...failure to secure adequate suction flow rate 4 Plumb a vacuum switch and an ejector with vacuum switch at the end of vacuum system as much as possible A long distance between a vacuum switch and a vacuum system end may increase plumbing resistance which may lead to a high vacuum level at the sensor even when no suctioning and a malfunction of vacuum switch Make sure to evaluate the products in an ...

Page 20: ...cuum Generator Series Vacuum Generator 49 VACUUM GENERATOR 9 The material of plastic filter cover for VQ and VFU series is PA Avoid the adherence of chemicals below to the products and do not use them under those chemical environments Table Chemical Name There are more chemicals which should be avoided Contact us for the use under chemical circumstance ...

Page 21: ...ected dropping the performance or having an effect to other vacuum ports can be caused depending on number of stations or a combination of mounting units Contact us for any unclear points 3 Compressed air contains many kinds of drains such as water oxidized oil tar and other foreign substances Dehumidify the compressed air by using an after cooler or a dryer and improve the air quality since those...

Reviews: