■ Method for Attaching / Detaching DIN Rail Bracket and DIN Rail
Screw for Manifold-block
(1)
DIN Rail
DRF35S Mounting Screw
(2)
(3)
(1) Fix a solenoid valve on DIN Rail Bracket (DRF35S) by tightening a screw. (*1).
*1 Use a screw with the designated size.
Screw: M4x0.7 (L=62~64)
(2) Mount DIN Rail Bracket (DRF35S) on DIN Rail. Tighten the fixing screw of DIN Rail Bracket (DRF35S) with
the designated tightening torque in the below table.
■
Table. Tightening Torque of Fixing Screw
Tightening Torque for Fixing Screw
0.3 ~ 0.4N·m
Max. Load
100N
(3) Loosen the fixing screw of DRF35S and lean forward the solenoid valve in the way like pulling it up, detach it
from the rail as following figure shows.
Safety Instructions for DIN Rail Mounting Bracket
1. Fixing shall be tightened within the designated tightening torque.
2. Do not place anything which exceeds the maximum load on DIN Rail and Bracket.
3. Do not place DIN rail on a place with extreme vibration (9.8m/s
2
or less).