Safety instruction manual

Warnings

1.When the fluid medium is chemicals, solvents or mixed gases, c

heck 

the 

chemical resistance before using the products

.

 Damage or

leakage

 

may occur to the valve upon the usage.

2.

Do not use the valve 

in

 applications 

that

 cause shak

ing

 or shock

ing.  Damage or leakage may occur to the valve upon usage

.

3.

Do not use the products 

in environments

 

 that have 

vibration or shocking. D

amage or leakage may occur to the valve upon usage.

4.

Use soapy water or 

any 

other method to 

check for

 leakage before use.

5.

After 

i

nstallation, carry out maintenance 

and leakage inspections 

periodically, considering 

the 

environment

 on

 frequency,

temperature, fluid flow rate, pressure, fluid medium, etc. 

 Danger to 

to human life 

can occur 

from oxygen deficiency etc.

6.

Do not retighten the product while pressur

ized

. Valve deformation or breakage may occur and lead to fluid spouting. Make sure

 

to set

pressure to “0” and lower the temperature to normal before retightening.

7.

Do not use the valve outside

 of its stated

 specification. Otherwise accidents like a fluid leakage or piping coming-off may 

occur

.

8.

Fluid and pressure  may remain inside  the valve 

when

 turning it to on/off while pressure is supplied.  The residual  fluid pressure may

increase due to 

rise in 

temperature

.  If 

the pressure exceeds maximum operating pressure

, valve breakage or fluid leakage may occur

.

9.The b

all seat may deform

 or wear out, and cause 

leakage in case

s where

 fluid medium has high temperature and high flow rate or is

 a

two-phase fluid

 

mixed with small particles.

10.

When open

ing or 

clos

ing

 the valve, turn the handle to 

the 

fully open

 or 

closed position. 

Leaving the handle in the m

id

-

way position

 

may

cause scratch

ing 

on 

the 

ball seat, fluid

 

leakage and decrease

 

lifespan

 for the valve

.

11.Used alone, the m

ax

imum

 operating pressure of the valve is 

its own stated maximum operating pressure.  However,

  

w

hen using

 the

valve

 with 

push-in fitting, the max

imum

 operating pressure should be t

hat of 

the push-in fitting.

Cautions

1.

Do not disassemble or modify valve except

 for

 replacing handles. 

Doing so will dam

age the valve function.

2.

Do not touch valve while using in 

high temperature environment.

3.

Make sure to understand 

the 

valve

's components'

 material properties, considering the fluid medium and usage environment before

use. Most parts are

 

made of SUS316 equivalent

,

 but some parts where 

the 

fluid

 medium

 does not

 come into contact

 are made from

SUS304 equivalent.

4.

Consider the load

-bearing of 

the piping when installing

 the 

valve as it may cause deformation and leakage.

5.

Do not tighten 

the thread 

too firmly. Excessive tightening can deform 

the 

valve body and ball seat. Follow the tightening torque 

guide 

for

tube fitting

s

.

6.

Make sure to 

position the

 wrench 

properly

 when tightening the valve

.  Otherwise, improper positioning

 may cause parts

 to loosen

.

7.

The valve is not completely oil-free as oil may remain from 

the 

assembly process.

8.

The level of corrosion and dust emission from 

the 

valve varies by operating conditions. In case there is a possibility of negative

 

effects

on

 

machines or facilities due to these 

operating 

conditions, evaluate the suitability of the products in advance.

9.

Depending on the service fluid and/or frequency of open

ing and closing the

 valve,

 the

 PTFE seal portion may 

wear out

 and generate

dust

.

 

If 

your 

application does not allow any dust emission, please take countermeasures like installing filters

 located

 downstream of the

valve.

10.

When us

ed in

 vacuum systems, install a filter 

located in 

the upstream of the valve to prevent from clogging.

11.

Specialized SUS316 fittings 

have been made specially to be used with the

 NSBVF10 ball valves. 

Using them for other uses 

 may cause

leakage.

1. The level of corrosion and dust emission from the fittings varies by operating conditions. In case there is a possibility of negative

effects on machines or facilities due to these conditions, evaluate the suitability of the products in advance.

SUS316 fitting safety instruction

Warnings

:KHQ

the fluid medium is

FKHPLFDOVVROYHQWVDQGPL[HGJDVHVFKHFNFKHPLFDOUHVLVWDQFH

before using the products

 

Cautions

2.

3.

'HSHQGLQJ RQ

the 

FRQGLWLRQV

the fluid medium

PD\FDXVHGDPDJHWRWKHILWWLQJV

 such as 

WKHWXELQJFRPLQJRIIDQGIOXLGOHDNDJH

Do not use the product in applications where water and liquid do not meet the product specification.  Otherwise, it may cause 
damage to the fittings, such as the tubing coming off and fluid leakage.  
 Be sure to use an Insert Ring when the fluid being used is liquid. There is a possibility of the tubing coming off and fluid leakage 

in the following situation. 

Using with fluid whose temperature changes drastically or under conditions where the temperature changes drastically.

Using in high temperature environments.

Summary of Contents for SUS316 equivalent

Page 1: ...le for Space saving 3 piece structure Easy maintenance by retightening nuts Max service pressure 1000psi 6 9MPa Wide range of use 30 series 3 piece structure Full bore Option for10 series compact body Feature Ball Valve feature SUS316 equivalentisusedforliquid contacting part SUS316 or CF8M The stem does not come off Structure preventing stem from detachment Feature ...

Page 2: ... size Code 02 03 04 Size R1 4 R3 8 R1 2 Tubing O D size Code 44 66 88 1010 1212 1616 Tubing O D ø4 5 32 ø6 ø8 5 16 ø10 ø12 ø16 5 8 Tubing O D 6 8 10 12 16 ø6 ø8 5 16 ø10 ø12 ø16 5 8 04 44 02 03 M Option for 10 series Ball Valve Model Designation Example Code 02 03 04 Size Rc1 4 Rc3 8 Rc1 2 Rc stands for BSPP female thread Code 10 30 Construction 1 piece reduced bore 3 pieces full bore Stainless St...

Page 3: ...ent PTFE SUS304 equivalent Stainless steel Stainless steel PTFE PVC SUS316 equivalent PTFE Washer SUS304 equivalent Disc spring washer SUS304 equivalent No SUS316 equivalent SUS316 equivalent SUS316 equivalent PTFE SUS304 equivalent Stainless steel Stainless steel PTFE PVC Cover Body SUS316 equivalent Gland nut Stainless steel Retainer seal PTFE Bolt Stainless steel Nut Stainless steel Spring wash...

Page 4: ...9 2 Rc1 2 56 6 27 3 27 5 91 5 1 5 44 5 1 5 24 5 171 NSBVF10 1 piece construction Reduced bore 10 series Price 18 00 19 82 23 73 øP E4 E3 2 øD 2 C E1 E2 øP 2 H1 2 H2 ø4 ø6 type Unit mm Model Tubing O D øD øP Tube End C E1 E2 E3 E4 Hex H1 Hex H2 Weight g Orifice dia ømm NSBV10 44 4 18 6 14 9 30 95 30 05 63 4 1 5 33 5 1 5 16 5 17 94 3 5 200 NSBV10 66 6 18 6 16 8 34 1 33 2 63 4 1 5 33 5 1 5 16 5 17 10...

Page 5: ...8 26 4 23 3 24 48 11 35 00 SSPC16 04M 16 R1 2 9 34 6 26 4 24 24 55 13 36 36 SSPC SUS316 fitting for SUS316 equivalent 10 series models Price Orifice dia E2 B2 2 L5 E3 2 L4 L2 L3 E1 B1 Image of installation 2 L1 ød Unit mm Model B1 B2 L1 L2 L3 L4 L5 E1 E2 E3 ød Weight g NSBL10 02 43 4 14 12 23 6 3 1 4 8 21 7 7 22 5 6 6 3 64 NSBL10 03 48 2 16 12 26 8 4 4 9 23 2 8 24 7 6 8 4 3 82 NSBL10 04 63 18 14 2...

Page 6: ...and usage environment before use Most parts are made of SUS316 equivalent but some parts where the fluid medium does not come into contact are made from SUS304 equivalent 4 Consider the load bearing of the piping when installing the valve as it may cause deformation and leakage 5 Do not tighten the thread too firmly Excessive tightening can deform the valve body and ball seat Follow the tightening...

Page 7: ...tation Storage Installation Turn the valve handle to the fully open position when transport or store otherwise it may lead to ball seat deformation Store the valve indoor avoiding dust and foreign matter To prevent from dust and foreign mater do not unwrap packaging before installation Before installation use air blow or water to clean valve internal IN OUT flow can be connected to both side of va...

Page 8: ...and nut and flange bolt nut for NSBVF30 4 Retighten the nut by 1 4 turns watching leaking condition Retighten 4 flange bolts evenly Handle Nut Gland Nut Flange bolt Nut Turn the handle 90 counterclockwise Open to open the valve and turn 90 clockwise Shut to close the valve Tighten the nuts in diagonal order so that they should be tightened evenly SUS316 Push in Fitting has been remodeled Now the b...

Reviews: