PISCO FH10 Manual Download Page 9

S

afety 

I

nstructions

 

SAFETY INSTRUCTION MANUAL

 Danger

1. Do not use PISCO products for the following applications.

① Equipment used for maintaining / handling human life and body.

② Equipment used for moving / transporting human.

③ Equipment specifically used for safety purposes.

 Warning

1. Do not use PISCO products under the following conditions.

① Beyond the specifications or conditions stated in the catalog, or the instructions.

② Under the direct sunlight or outdoors.

③ Excessive vibrations and impacts.

④ Exposure / adhere to corrosive gas, inflammable gas, chemicals, seawater, water and vapor. *

* Some products can be used under the condition above(④), refer to

the details of specification and condition of each product.

2. Do  not  disassemble  or  modify  PISCO  products,  which  affect  the

performance, function, and basic structure of the product.

3. Turn off the power supply, stop the air supply to PISCO products, and make sure

there is no residual air pressure in the pipes before maintenance and inspection.

4. Do not touch the release-ring of push-in fitting when there is a working pressure.

The lock may be released by the physical contact, and tube may fly out or slip out.

5. Frequent switchover of compressed air may generate heat, and there is a

risk of causing burn injury.

6. Avoid  any  load  on  PISCO  products,  such  as  a  tensile  strength,  twisting

and bending. Otherwise, there is a risk of causing damage to the products.

7. As  for  applications  where  threads  or  tubes  swing  /  rotate,  use  Rotary

Joints,  High  Rotary  Joints  or  Multi-Circuit  Rotary  Block  only.  The  other

PISCO products can be damaged in these applications.

8. Use only Die Temperature Control Fitting Series, Tube Fitting Stainless SUS316

Series, Tube Fitting Stainless SUS316 Compression Fitting Series or Tube Fitting

Brass Series under the condition of over 60℃ (140°F) water or thermal oil. Other

PISCO products can be damaged by heat and hydrolysis under the condition above.

9. As  for  the  condition  required  to  dissipate  static  electricity  or  provide  an  antistatic

performance, use EG series fitting and antistatic products only, and do not use other PISCO

products. There is a risk that static electricity can cause system defects or failures.

10. Use  only  Fittings  with  a  characteristic  of  spatter-proof  such  as  Anti-

spatter  or  Brass  series  in  a  place  where  flame  and  weld  spatter  is

produced. There is a risk of causing fire by sparks.

11. Turn  off  the  power  supply  to  PISCO  products,  and  make  sure  there  is

no  residual  air  pressure  in  the  pipes  and  equipment  before  maintenance.

Follow the instructions below in order to ensure safety.

① Make sure the safety of all systems related to PISCO products before maintenance.

② Restart of operation after maintenance shall be proceeded with care after

ensuring safety of the system by preventive measures against unexpected

movements of machines and devices where pneumatic equipment is used.

③ Keep enough space for maintenance when designing a circuit.

12. Take safety measures such as providing a protection cover if there is a

risk of causing damages or fires on machine / facilities by a fluid leakage.

PISCO products are designed and manufactured for use in general industrial 

machines. Be sure to read and follow the instructions below.

Summary of Contents for FH10

Page 1: ...30 15 Make to order products Vacuum Cup Ball Swiveling Attachment Swivel Joint Suitable for sucking work pieces with non vertical position or with unfixed angle http www pisco com ...

Page 2: ...urling part of FH10 and FH20 or use a spanner to tighten the parallel cut part of FH60 Refer to the dimensional drawings of the parallel cut part Code Pad size mm 10 ø10 ø15 Code Oscillatingangle No code 30 ー 15 15 option 20 ø20 ø50 4 10 8 30 60 ø60 ø100 Holder size code 20 is applicable for pad size ø10mm and ø15mm for sponge series due to the structural reasons FH10 and FH20 FH60 ...

Page 3: ...ressure Otherwise the work piece may drop from the vacuum pad during transportation and there is a possibility of damaging the holder 3 Avoid any excessive pressure on Free Holder Otherwise there is a possibility of damaging the holder Caution 1 Pay special attention to the angle position of Free Holder The angle position can be changed after sucking work piece by work piece weight and acceleratio...

Page 4: ...sh In Fitting VPD Push In Fitting VPF Push In Fitting Holder model code FH 10 Pad dia ø10 15mm Free Holder Pad dia ø10mm ø15mm Standard Series Pad dia ø10mm Bellows Series compliant Unit mm Model code M1 M2 A1 A2 B L1 L2 øP Hex H1 Hex H2 Weight g CAD file name FH10 M4 0 7 M4 0 7 3 4 7 23 19 6 11 1 15 4 9 VVP 229 FH20 M6 1 M6 1 6 6 5 28 5 22 5 12 5 20 7 19 5 FH60 M10 1 5 M10 1 5 10 9 5 40 5 30 5 18...

Page 5: ... Barb Fitting VPB Barb Fitting VPC Barb Fitting VPD Barb Fitting VPB Push In Fitting VPC Push In Fitting VPD Push In Fitting VPF Push In Fitting Pad dia ø20mm ø25mm ø30mm ø40mm ø50mm Standard Series Pad dia ø20mm ø30mm ø40mm ø50mm Skidproof Series Pad dia ø10mm ø15mm ø20mm ø25mm ø30mm Sponge Series Pad dia ø35mm ø50mm Sponge Series Pad dia ø20mm ø30mm ø40mm ø50mm Bellows Series Pad dia 4 10 20 30m...

Page 6: ...female thread VPB Parallel female thread VPC Parallel female thread VPD Parallel female thread Model code FH 60 Pad dia ø60 70 80 100mm Swivel Joint Pad dia ø60mm Standard Series Pad dia ø80mm ø100mm Standard Series Pad dia ø80mm Bellows Series Pad dia ø70mm ø100mm Sponge Series ...

Page 7: ...PISCO products and constitute all systems based on the latest catalog or information considering any malfunctions 2 Handle the pneumatic equipment with enough knowledge and experience Improper use of compressed air is dangerous Assembly operation and maintenance of machines using pneumatic equipment should be conducted by a person with enough knowledge and experience 3 Do not operate machine equip...

Page 8: ...accidental damages of PISCO products due to incorrect usage 3 PISCO does not take any responsibility for any loss caused by improper usage of PISCO products such as exceeding the specification limit or not following the usage the published instructions and catalog allow 4 PISCO does not take any responsibility for any loss caused by remodeling of PISCO products or by combinational use with non PIS...

Page 9: ...uit Rotary Block only The other PISCO products can be damaged in these applications 8 Use only Die Temperature Control Fitting Series Tube Fitting Stainless SUS316 Series Tube Fitting Stainless SUS316 Compression Fitting Series or Tube Fitting Brass Series under the condition of over 60 140 F water or thermal oil Other PISCO products can be damaged by heat and hydrolysis under the condition above ...

Page 10: ...ch size Nylon tube Polyurethane tube ø1 8mm 0 05mm ø1 8 0 1mm 0 15mm ø3mm 0 15mm ø5 32 0 1mm 0 15mm ø4mm 0 1mm 0 15mm ø3 16 0 1mm 0 15mm ø6mm 0 1mm 0 15mm ø1 4 0 1mm 0 15mm ø8mm 0 1mm 0 15mm ø5 16 0 1mm 0 15mm ø10mm 0 1mm 0 15mm ø3 8 0 1mm 0 15mm ø12mm 0 1mm 0 15mm ø1 2 0 1mm 0 15mm ø16mm 0 1mm 0 15mm ø5 8 0 1mm 0 15mm 6 Instructions for Tube Insertion Make sure that the cut end surface of the tub...

Page 11: ...thread or a fluid leakage Adjust the tube direction while tightening thread within these limits since some PISCO products are not rotatable after the installation Table 2 Recommended tightening torque Sealock color Gasket materials Thread type Thread size Tightening torque Sealock color Gasket materials Metric thread M3 0 5 0 7N m SUS304 NBR M5 0 8 1 0 1 5N m M6 1 2 2 7N m M3 0 5 0 5 0 6N m POM M5...

Page 12: ...de a protective cover on the products when it is exposed to sunlight 8 Carry out clogging check for silencer element in an ejector and a vacuum filter periodically Clogged element will be a cause to impair the performance or a cause of troubles 9 Before replacing the element thoroughly read and understand the method of filter replacement in the catalog 10 Make sure the correct port of the vacuum g...

Page 13: ...an ejector with vacuum switch at the end of vacuum system as much as possible A long distance between a vacuum switch and a vacuum system end may increase plumbing resistance which may lead to a high vacuum level at the sensor even when no suctioning and a malfunction of vacuum switch Make sure to evaluate the products in an actual system 5 Refer to 4 Instructions for Installing a fitting and 5 In...

Page 14: ...drogen peroxide Vacuum Generator Series 9 The material of plastic filter cover for VQ and VFU series is PA Avoid the adherence of chemicals below to the products and do not use them under those chemical environments Table Chemical Name There are more chemicals which should be avoided Contact us for the use under chemical circumstance ...