MAINTENANCE

When installed in accordance with the instructions, the Pisko ladder and roof safety products are durable and 

safe to use due to the continuous quality control and research work conducted by Piristeel Oy.

In order to ensure the safe use and durability of the products, the property owner must perform the annual 

inspection and maintenance procedures and ensure that the snow load stipulated in the regulations is not 

exceeded.

If a vertical profile has been installed in the ladder, the owner of the property must have it checked annually 

by a person authorized by the manufacturer.

•  inspecting the tightness of the joints and fastening points

•  checking the wall and roof fastenings 

•  checking the watertightness of the lead-ins in the roof 

•  taking care of the removal of excess snow in order to minimize the loading of the structures and 

   fastening points (several times during the winter, if necessary) 

•  removing snow and ice from the ladder, if necessary 

•  checking the condition of the paint or zinc coating of the products, as well as repairing and touch-up 

   painting local damages 

•  replacing or repairing damaged or defective parts as soon as possible.

The annual inspection and maintenance of the Pisko ladder and roof safety products include

Summary of Contents for pisko SAFEGRIP

Page 1: ...r 2 Bow 3 Support arc for the bow 4 Bow fastener for the roof L shaped 5 Bow fastener for the roof U shaped 6 Bow fastener kit for the walkway 7 Bow fastener kit for a tiled roof 8 Wall ladder leg 9 Wall ladder clip 10 Eaves support 11 Mounting plate for sandwich panels 12 Anti climb guard 1 2 5 11 12 3 4 6 7 8 9 10 ...

Page 2: ...tened to the ladder with wall ladder clips so that the topmost pair of legs is located as close to the eaves as possible and the bottom pair of legs is located between the first and second rung Efforts must be made to always fasten the wall ladder legs to the load bearing structures of the wall In the case of brick cladded houses it is advisable to install the wall ladder legs in the frame structu...

Page 3: ...e aid of the adjustment openings the connector can be aligned with the bows in the direction of both the pitched roof area and the ridge The connector is fastened to the auxiliary batten fasteners with two M8x16 screws The bows are fastened to the connector with two M8x40 screws 4 x 7 x 50 LVI RUUVI Fastening the Wall Ladder to the Roof Ladder Fastening the Wall Ladder to the Roofing Fastening the...

Page 4: ...ning requirements the clear width of the ladder rungs is 400 mm and their distance from each other is 300 mm The ladder is manufactured from hot dip galvanized steel tube The side rails are made of oval 25x45 mm tube and the rungs are made of roughened 25 mm tube The rungs are attached to the side rails via riveting while the other joints are screw joints Fastening the Bows to the Ladder Frame USE...

Page 5: ...st have it checked annually by a person authorized by the manufacturer inspecting the tightness of the joints and fastening points checking the wall and roof fastenings checking the watertightness of the lead ins in the roof taking care of the removal of excess snow in order to minimize the loading of the structures and fastening points several times during the winter if necessary removing snow an...

Page 6: ...mm Withstands a load of 2 6 kN a Static load bearing capacity of the side rail With a 1 5 kN load the maximum deflection is 10 mm and 1 100 of the length of the bracket interval Withstands a load of 2 6 kN c Static load bearing capacity of the ladder s fastening and the wall ladder legs Withstand a load of 2 6 kN d Torque resistance capacity of the rung s fastening Withstands a torque of 50 Nm e D...

Reviews: