A962
ADJUSTMENT
LOCATIONS
TEST JIG
REFER TO
FIGURE 9 - 9
Figure 9-3 Fuel Quantity Transmitter Checking Jig
SEND IGN
GND 14 VDC
0 10 15 F
LEFT FUEL
U.S. GAL.
0 10 15 F
RIGHT FUEL
U.S. GAL.
CALIBRATION CHART
GRADUATION
OHMS
DEGREES
TOLERANCE *
DOT MECH. ZERO
—40°
±1/2
0
3
—32
-1+0
5
14
—15°
±1
10
23
+2
±1
15
33
+20
±1
F
45
+32°
±1/2
*—NOTE—
TOLERANCE IS IN
POINTER WIDTHS
(USE 14 VOLTS)
Figure 9 -4. Fuel Quanity Indicators
PIPER AIRCRAFT
PA-28-161 CADET
AIRPLANE MAINTENANCE MANUAL
Issued: FEBRUARY. 28, 1989
FUEL SYSTEM
2A17