background image

 -9- 

 

0.2             0.4             0.6              0.8             1.0              1.2              1.4              1.6 

„TOO HOT“

   

The temperture measured by the PCB has 
reached a maximum. In this case the power  
output will be locked automatically to avoid 
heat damage. 

Avoid any usage of the device for not less 
than 10 minutes! If the error message  
appears frequently during normal use 
check the power 

[W]

 and temperature 

[C

F]

 settings as well as the coil resistance 

[Ω]

! Extreme setups at the upper power 

range can cause intense heating of the  
atomizer and PCB. Therefore, avoid  
permanently using such setups! 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Specifications 

 

 

Output Power 

 

1,0 - 75,0 W 

 Output Voltage 

 

0,2 - 6,2 V 

Output Current  

(max. continuous) 

 

30,0 A 

Output Current  

(max. instantaneous) 

 

40,0 A 

Resistance atomizer/coil  

(temperature controll, cold) 

 

see fig. 

Resistance atomizer/coil  

(power controll, TC=0) 

 

see fig. 

Temperature controll  200 - 600° F 

100 - 300 °C 
 

Input Voltage 

 

3,0 - 4,2 V 

Input Current 

 

5,0 - 28,0 A 

Input Current  

(max. instantaneous) 

 

32,0 A 

Power consumption  

(Display 100%) 

 

26 mA 

Power consumption  

(Standby) 

 

7 mA 

Efficiency  85% 

 

   
   
   
   
   
   

   
   
   
   
   
   

 
 
 
 
 
 
 
 
 
 
 
 
 

80 

 

70 

 

60 

 

50 

 

40 

 

30 

 

20 

 

10 

Temperature controll, cold 

Power controll, TC=0 

Wa

tt

ag

/ W

 

Resistance / Ω

 

Summary of Contents for SERIES-B DNA 75W

Page 1: ...ruction Manual Description Operating First setup Functions Features Important Information Advanced Operating Temperature Control EScribe Error Messages Specifications Instruction for use SERIES B DNA...

Page 2: ...mend a suitable external charger 3 Replace the magnetic battery cover 4 If the battery needs to be charged and a suitable external charger is not available you can also charge the battery in the devic...

Page 3: ...e a prompt will appear after briefly pressing asking if you are using a new atomiser If desired a new resistance reading will be taken or you can use the preset resistance If the resistance of the ato...

Page 4: ...oltage of your battery continuously If due to insufficient capacity the voltage falls below a definable limit idle or loaded the power output will be locked automatically to avoid exhausting the batte...

Page 5: ...ance changes the SERIES B DNA 75W can determine the temperature of the heating coil Please ensure that the wraps of the coil do not touch and the contacts of the 510 port and within the atomizer used...

Page 6: ...r Mac with access to the internet and a USB 2 0 interface For setup please open the following link with a browser on your choice https downloads evolvapor com SetupEScribe2_INTL exe https downloads ev...

Page 7: ...downloads evolvapor com escribe EScribeManual pdf Furthermore Evolv provides an interactive training course https downloads evolvapor com escribe guide story html Tips and tricks custom display design...

Page 8: ...external charger or use the included USB charging lead Operating TEMPERATURE PROTECTED The selected temperature C F was reached during firing In this case the power output automatically will be throt...

Page 9: ...heating of the atomizer and PCB Therefore avoid permanently using such setups Specifications Output Power 1 0 75 0 W Output Voltage 0 2 6 2 V Output Current max continuous 30 0 A Output Current max i...

Page 10: ...riod is not recommended Possible negative effects on your health At this time we are not aware of any studies present that would indicate harmful effects of our products to your health However this do...

Reviews: