Pioneer YN009GMFI22RPD Installation Manual Download Page 10

8

installation manual

M

N

P

ll

a

w

 

k

c

a

b

 

m

o

r

2

1

 /

 

m

c

 

30

    

      

    IF USING BRACKETS

          

    10 cm/4” is enough 

      

        

t

h

g

i

r

 

n

o

 

4

2

 

/

 

m

c

 

0

6

60

cm

/

2

4

above

t

f

e

n

o

 

2

1

 

/

 

m

c

 

0

3

n

o

r

n

8

7

 

/

 

m

c

 

0

0

2

t

Fig. 6.10

Drain Joint Installation

Before bolting the outdoor unit in place, you must install 
the drain joint at the bottom of the unit. (See Fig. 6.11)

1. Fit the rubber seal on the end of the drain joint that 

will connect to the outdoor unit.

2. Insert the drain joint into the hole in the base pan of 

the unit.

3. Rotate the drain joint 90° until it clicks into place, 

facing the f ront of the unit.

4. Connect a drain hose extension (not included) to 

the drain joint, to redirect water f rom the unit during 
heating mode.

NOTE:

 Make su re the water drains to a safe location 

where it will not cause water damage or a slipping 
hazard.

Seal

Drain Joint

(A)

(B)

Base Pan Hole of 
Outdoor Unit

Seal

Fig. 6.11

Notes On Drilling Hole In W all

You must drill a hole in the wall for the refrigerant piping, 
and the signal cable that will connect the indoor and 
outdoor units.

1. Determine the location of the wall hole, based on the 

location of the outdoor unit. 

2. Using a 65-mm (2.56”) core drill, drill a hole into the 

wall.

NOTE:

 When drilling the wall hole, make sur e

to avoid wires, plumbing, and other sensitive 
components.

3. Place the protective wall cu ff inside the hole. This 

protects the edges of the hole, and will help seal it 
when you finish the installation process.

NOTE:

The minimum distance between the outdoor 

unit and walls described in the installation guide does 
not apply to airtight rooms. Be sure to keep the unit 
unobstructed in at least two of the three vectors (M, 
N, P) (See Fig. 6.10)   

CAUTION

The drain pipe of the indoor unit must be heat-insulated, or it,as 
well as the connections of the indoor unit, will condense dew.

Hard PVC binder must be used for the pipe connection. Make 
sure there is no leakage.

7.    CONNECT THE DRAIN PIPE

Install the Drainpipe of the Indoor Unit

The outlet has PTI screw thread, please use sealing materials 
and a pipe sheath (fitting) when connecting the PVC pipes. 

Drainage test

Check whether the drainpipe is unhindered.

Newly-built  houses  should  have  this  test  done  before 
paving the ceiling.

With the connection part to the indoor unit, please ensure not to 
apply pressure on the side of indoor unit pipes.

When the declivity of the drain pipe downwards is over 1/100, 
there should not be any winding.

The total length of the drain pipe, when pulled out transversely, 
shall not exceed 20m. When the pipe is overlong, a prop stand 
must be installed to prevent winding. 

Refer to the figures below for the installation of the pipes. 

1.5m~2m

Insulating

material

Downward declivity

lower than 1/100 

Bend

S shape 

VP30

Downw ard declivity 

less than 1/100

Put as deep as possible

(about 10cm)

Fig. 7-1

Summary of Contents for YN009GMFI22RPD

Page 1: ...NOTICE Please read this manual carefully before installing or operating your new air conditioning system Be sure to save this manual for your future reference Installation Manual UAB UYB Series Flex Mount UAB Cooling Only Version UYB Cooling and Heating Version Inverter and Inverter Models 18 000 48 000 BTU hr ...

Page 2: ...If used as a part of a MULTI Split System please refer to the Installation Operation manuals packed with the multi split outdoor unit ...

Page 3: ...low For electrical work follow all local and national wiring standards and regulations as well as these installation instructions An independent circuit and single outlet must be used If the electrical circuit capacity is insufficient or there is a defect in the electrical work it will cause electrical shock fire Use the specified cable and connect tightly and clamp the cable so that no external f...

Page 4: ...ended for use by young children or infirm persons without supervision Don t install the air conditioner in the following locations Anywhere that contains unsealed petrolatum Areas with salt saturated air such as near the coast Areas with caustic gas sulfide for example existent in the air such as near a hot spring Areas with fluctuations in incoming power supply or unstable power where the voltage...

Page 5: ... some spare items please store them carefully aside QUANTITY SHAPE NAME 5 Owner s Manual 6 Installation Manual 7 Remote Controller Manual 1 Remote Controller on some models 2 Remote Controller Holder on some models 4 Alkaline Dry Batteries AM4 1 1 2 2 1 1 Remote Controller Its Holder Others 3 Mounting Screw ST2 9 10 C H 1 ...

Page 6: ... the unit take into account the following Fragile handle the unit with care Keep the unit upright in order to avoid compressor damage Pre determine the path along which the unit is to be brought in Move and carry this unit without changing its original packaging position by as much as possible When lifting the unit always use protectors to prevent belt damage and pay special attention to the posit...

Page 7: ...on Inlaying or embedding the screw bolts Install the hanging hook with expanding bolt into the concrete 45 50mm deep to prevent loosening Remove the side board and the grille Refer to Fig 5 8 Side Board Grille Hanging Arm Hanging Screw Bolt 20mm 3 4 In Unit Dimensions 5 3 Table 5 1 unit mm Fig 5 10 Fig 5 11 Fig 5 12 D Connecting Point of Refrigerant Pipe D Gas Side Drain point Downward declivity b...

Page 8: ...door and indoor unit must not exceed the maximum allowable pipe length If possible DO NOT install the unit where it will be exposed to direct sunshine If possible make sure the unit is located far away from your neighbors property so that the noise from the unit will not cause a disturbance for them If the location is exposed to strong winds for example near a seaside the unit must be placed again...

Page 9: ...sions W x H x D Mounting Dimensions Distance A Distance B 770x555x300 30 3x21 9x11 8 549 21 6 325 12 8 946x810x410 37 24x31 9x16 14 673 26 5 403 15 87 952x1333x415 37 5x52 5x16 34 634 24 96 404 15 9 845x702x363 33 27x27 6x14 3 540 21 26 350 13 8 800x554x333 31 5x21 8x13 1 514 20 24 340 13 39 YN048GMFI17RUD YN036GMFI17RUD 946x810x410 37 24x31 9x16 14 673 26 5 403 15 87 YN024GMFI22RPD YN018GMFI22RPD...

Page 10: ... the protective wall cuff inside the hole This protects the edges of the hole and will help seal it when you finish the installation process NOTE The minimum distance between the outdoor unit and walls described in the installation guide does not apply to airtight rooms Be sure to keep the unit unobstructed in at least two of the three vectors M N P See Fig 6 10 CAUTION The drain pipe of the indoo...

Page 11: ...Pipe Length and Elevation Ensure that the length of the refrigerant pipe the number of bends and the drop height between the indoor and outdoor units meets the requirements shown inTable 8 1 Table 8 1 The Maximum Length And Drop Height Based on Models Unit m ft Type of Model Capacity Btu hr Length of piping Maximum drop height 50Hz T1 Condition R22 Split Type 12K 15 49 8 26 18K 24K 30 98 4 10 32 8...

Page 12: ... perfect 90 angle Refer to Fig 8 1 for examples of bad cuts Oblique Rough Warped 90 Fig 8 1 Step 2 Remove burrs Burrs can affect the air tight seal of the refrigerant piping connection They must be completely removed 1 Hold the pipe at a downward angle to prevent burrs from falling into the pipe 2 Using a reamer or deburring tool remove all burrs from the cut section of the pipe Pipe Reamer Pointe...

Page 13: ... to tighten the flare nut according to the torque values in table 8 2 NOTE Use both a spanner and a torque wrench when connecting or disconnecting pipes to from the unit Fig 8 7 CAUTION Be sure to wrap insulation around the piping Direct contact with the bare piping mayresult in burns or frostbite Make sure the pipe is properly connected Over tightening may damage the bell mouth and under tightenin...

Page 14: ... and LIQUID Valves 1 Connect the blue low side hose of the manifold gauge to service port on the outdoor unit s GAS SIDE valve use a 1 4 to 5 16 port adapter if needed which is sold separately 2 Connect yellow middle or common hose from the manifold gauge to the vacuum pump MC MC Fig 6 1 Air and foreign matter in the refrigerant circuit BLUE Low Pressure Side of Manifold Gauge RED High Pressure Si...

Page 15: ...th the LIQUID side and GAS side Service Calves 13 Tighten valve caps on all three valves service port Liquid Side Gas Side by hand Then tighten it further using a torque wrench if needed OPEN VALVE STEMS GENTLY When opening valve stems turn the hexagonal wrench until it seats against the stopper Do not try to force the valve to open further Note on Adding Refrigerant ADDITIONAL REFRIGERANT PER PIP...

Page 16: ... on the power until you have carefully checked everything after wiring The power cord type designation is H07RN F 2 The Outdoor Unit Check a Whether there are any vibrations or abnormal noises during operation b Whether the generated wind noise or condensation from the air conditioner create any local disturbances c Whether any of the refrigerant has leaked After restarting a protection feature pr...

Page 17: ...15 installation manual ...

Page 18: ...ales agency or manufacturer for details 16122700000004 20171209 is a registered trademark of Parker Davis HVAC International Inc Parker Davis HVAC International Inc 2250 NW 102 Place Doral FL 33172 USA Tel 305 513 4488 Fax 305 513 4499 email info pd hvac com Website www pd hvac com Copyright 2017 Parker Davis HVAC International Inc All rights reserved ...

Reviews: