6
Engb
System set-up
WARNING
!
Loudspeaker systems are potentially dangerous objects if used incorrectly. Please ensure that you read this section fully, and contact your local dealer should you be in
any doubt over correct operation procedures.
!
Professional loudspeaker systems are capable of producing damage-inducing sound pressure levels, and hence care should be taken when setting your system up,
particularly when it comes to loudspeaker placement within a venue. Damage to the ear can result from levels above 90 dB under prolonged exposure.
Ground stacking
!
Ensure that the floor or stage surface can withstand the weight of the system.
!
Wherever possible, avoid high stacks and use ratchet straps to secure loudspeakers together. Please also remember that vibrations from subwoofer systems can shake
other loudspeakers out of place, which may present a toppling hazard. The use of ratchet straps and non-slip material is recommended to prevent this.
Cabling and amplifier selection
The XY-218S is designed to be used with professional power amplifiers providing the following power outputs:
!
3200 W/channel into 4
W
NOTE
A small power amplifier working too hard is more likely to damage a loudspeaker than a large power amplifier working within its operating range.
It is good practice to use an amplifier equal to the program power rating of the loudspeaker — so as to retain sufficient headroom and good dynamic range. Care should be
taken during operation to avoid amplifier clipping — as this can cause serious damage to your loudspeakers. If in doubt, please contact your dealer who will be happy to assist
you in correct amplifier choice and setup.
Cabling
The XY-218S is supplied as standard with Neutrik SpeakON
™
NL4 connectors, wired pin 1+/1–. It is recommended that the resistance of your cable be less than one tenth of
the nominal system impedance. Given below are the recommended maximum cable lengths for different cross-sections and impedances.
Conductor cross sectional area
Maximum recommended cable length
4
W
8
W
16
W
1.0 mm
2
11 m
22 m
44 m
1.5 mm
2
17 m
34 m
68 m
2.0 mm
2
22 m
44 m
88 m
2.5 mm
2
29 m
58 m
116 m
4.0 mm
2
44 m
88 m
176 m
6.0 mm
2
66 m
132 m
264 m
!
Pins 2+/2– on the Neutrik SpeakON
™
connectors are wired together to allow link-through with 4-core cables.
Speaker protection and Processor setting
WARNING
The XY-218S requires at the minimum an active low pass filter to function correctly. Excessive low frequency information will cause the LF drive unit’s excursion to increase,
which can result in damage to your loudspeaker.
It is recommended to appropriately set the values of crossover frequency and peak limiter on the amplifier for loudspeaker protection.
Please refer to the PDF file in the “Installation Manual” and “Processor Settings” of the following webpage for the recommended values of crossover frequency and peak lim-
iter to appropriately use this product.
http://pioneerproaudio.com/ja/resources.html
Attachment of the CP-XYCS1 Castor Set
Attach the dedicated castors to the four mounting holes on the rear.
NOTE
We will not be liable if you use any castors other than the dedicated ones.