29
XC-F10
6. ADJUSTMENT
STOP
MAIN UNIT
for two seconds
STEST
Short
TEST MODE
TEST MODE : ON
TEST
MODE
TEST MODE
Short
CD TEST MODE : CANCEL
TEST MODE : STOP
STOP
The function is changed.
Becomes a usual CD operation
MAIN UNIT
C
SIDE A
6.1.1 How to Start/Cancel Service Test Mode
6.1 TEST MODE
NOTE: There is no information to be shown in this CD adjustment.
Fig. 1 Test Mode Point Location
An initial function becomes CD, then becomes CD TEST MODE. And becomes a blank display [ : ].
Kind of test mode
The following four modes exist.
The door opening function with the infrared rays sensor becomes off in the test mode (Infrared rays is not irradiated).
1-1. TEST mode. (TEST)
: For adjustment in main body distance of production line
1-2. Unit TEST mode. (UTEST)
: For inspection by the function checker of production line
1-3. Service TEST mode. (STEST)
: For inspection by service
It is not possible to operate at all by recognition because of there is no AC pulse if it is CD tuner alone and there is no part AMP as the power
failure.
Then, to be able to move the CD tuner, mode yet in the inconvenience without the part AMP.
It is possible to operate only in the CD tuner even if the part AMP is not connected.
An initial function becomes CD if the product starts in this mode, and CD becomes CD TEST mode different from a usual operation.
Even if the function is returned to the CD function again, the product does not become CD TEST mode when the function is made functions
other than CD once. The product becomes a usual CD operation.
To put the product from the state in the CD TEST mode, the remote control code of A25F is received.
1-4. CD TEST mode. (STEST)
: For inspection by service
When the remote control code of A25F is received at the CD function when it is on, power becomes CDTEST mode.
The CD tuner is effective to this even the ordinary mode.
However, the product becomes off this mode when the function is changed besides CD.
The step in the part CD can operate. From LD ON to SPDL LOCK , TRKG ON/OFF and etc.