background image

2

VSX-409RDS

1. SAFETY INFORMATION

This service manual is intended for qualified service technicians ; it is not meant for the casual do-it-
yourselfer. Qualified technicians have the necessary test equipment and tools, and have been trained
to properly and safely repair complex products such as those covered by this manual.
Improperly performed repairs can adversely affect the safety and reliability of the product and may
void the warranty. If you are not qualified to perform the repair of this product properly and safely, you
should not risk trying to do so and refer the repair to a qualified service technician.

WARNING
This product contains lead in solder and certain electrical parts contain chemicals which are known to the state of California to cause
cancer, birth defects or other reproductive harm.

Health & Safety Code Section 25249.6 – Proposition 65

NOTICE
(FOR CANADIAN MODEL ONLY)
Fuse symbols              (fast operating fuse) and/or               (slow operating fuse) on PCB indicate that replacement parts must
be of identical designation.

REMARQUE
(POUR MODÈLE CANADIEN SEULEMENT)
Les symboles de fusible               (fusible de type rapide) et/ou               (fusible de type lent) sur CCI indiquent que les pièces
de remplacement doivent avoir la même désignation.

ANY  MEASUREMENTS  NOT  WITHIN  THE  LIMITS

OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL

SHOCK HAZARD AND MUST BE CORRECTED BEFORE

RETURNING THE APPLIANCE TO THE CUSTOMER.

2. PRODUCT SAFETY NOTICE

   Many electrical and mechanical parts in the appliance
have special safety related characteristics. These are
often not evident from visual inspection nor the protection
afforded by them necessarily can be obtained by using
replacement components rated for voltage, wattage, etc.
Replacement  parts  which  have  these  special  safety
characteristics are identified in this Service Manual.
   Electrical components having such features are identified
by marking with a   on the schematics and on the parts list
in this Service Manual.
The use of a substitute replacement component which does
not have the same safety characteristics as the PIONEER
recommended replacement one, shown in the parts list in
this Service Manual, may create shock, fire,  or other hazards.
   Product Safety is continuously under review and new
instructions are issued from time to time. For the latest
information, always consult the current PIONEER Service
Manual. A subscription to, or additional copies of, PIONEER
Service Manual may be obtained at a nominal charge from
PIONEER.

1. SAFETY PRECAUTIONS

      The  following  check  should  be  performed  for  the
continued  protection  of  the  customer  and  service

technician.

LEAKAGE CURRENT CHECK

    Measure leakage current to a known earth ground (water
pipe, conduit, etc.) by connecting a leakage current tester
such as Simpson Model 229-2 or equivalent between the
earth ground and all exposed metal parts of the appliance
(input/output terminals, screwheads, metal overlays, control
shaft, etc.). Plug the AC line cord of the appliance directly
into a 120V AC 60Hz outlet and turn the AC power switch
on. Any current measured must not exceed 0.5mA.

(FOR USA MODEL ONLY)

Leakage
current
tester

Reading should
not be above
0.5mA

Device
under
test

Test all
exposed metal
surfaces

Also test with
plug reversed
(Using AC adapter
plug as required)

Earth
ground

AC Leakage Test

Summary of Contents for VSX-409RDS

Page 1: ...SX 409RDS RRV2200 1 SAFETY INFORMATION 2 2 EXPLODED VIEWS AND PARTS LIST 3 3 BLOCK DIAGRAM AND SCHEMATIC DIAGRAM 8 4 PCB CONNECTION DIAGRAM 24 5 PCB PARTS LIST 36 6 ADJUSTMENT 39 CONTENTS 7 GENERAL INFORMATION 40 7 1 DISASSEMBLY 40 7 2 PARTS 41 7 2 1 IC 41 7 2 2 DISPLAY 47 8 PANEL FACILITIES AND SPECIFICATIONS 49 T IZK SEPT 1999 Printed in Japan AUDIO VIDEO MULTI CHANNEL RECEIVER Type Model Power ...

Page 2: ...t evident from visual inspection nor the protection afforded by them necessarily can be obtained by using replacement components rated for voltage wattage etc Replacement parts which have these special safety characteristics are identified in this Service Manual Electrical components having such features are identified by marking with a on the schematics and on the parts list in this Service Manua...

Page 3: ...by NSP are generally unavailable because they are not in our Master Spare Parts List The mark found on some component parts indicates the importance of the safety factor of the part Therefore when replacing be sure to use parts of identical designation Screws adjacent to mark on the product are used for disassembly 2 CONTRAST TABLE VSX 409RDS MYXJIEW MVXJI and MYXJIGR are constructed the same exce...

Page 4: ...24 21 19 19 33 36 36 39 36 36 36 36 36 36 36 36 36 36 36 36 36 36 26 15 7 1 2 5 27 36 33 22 25 39 12 13 14 16 36 17 4 3 9 8 6 36 11 35 36 36 37 37 38 38 36 36 10 Accessory of Front Panel 36 34 36 36 36 36 Refer to 2 3 FRONT PANEL SECTION 39 39 29 28 30 36 36 31 32 23 2 2 EXTERIOR SECTION ...

Page 5: ...er Cord See Contrast table 2 20 Fuse T5A See Contrast table 2 1 EXTERIOR SECTION PARTS LIST Mark No Description Part No Mark No Description Part No 21 Fuse Holder See Contrast table 2 22 Top Cover 808 AME7375 NSP 23 Under Base 409 ANA7094 24 R Panel 409RDS ANC7844 25 Bonnet Case AZN7779 26 PCB Angle ANG7253 27 Shield R3 ANG7277 28 Heat Sink Angle F ANG7251 29 Heat Sink Angle R ANG7252 NSP 30 Heat ...

Page 6: ...SW Assy AWX7443 6 Volume Knob AAB7179 7 Power Button AAD7440 8 Power Button M AAD7442 9 Window W 409RDS AAK7683 10 F Button 409RDS AAD7537 Mark No Description Part No 11 Sub Panel 409RDS AAD7552 12 F Panel 409RDS AMB7644 13 Name Plate PAM1776 14 LED Lens PNW2019 NSP 15 Getter 409RDS AAX7727 16 Screw PPZ30P080FMC 17 Screw ABA7009 G B A 15 11 13 10 14 17 16 7 8 4 2 6 9 12 1 5 3 16 16 16 16 16 16 16 ...